17
Installation
11. Exhaust air pipeline
1:
Air outlet to outdoors
2:
Air outlet via an air shaft
• The exhaust air line should be as short
and straight as possible.
• To avoid excessive noise or a reduced
extraction capacity the diameter of
the exhaust air pipeline should not be
less than 150 mm.
• Use or form only large radius bends.
Small radius bends reduce the extrac-
tion capacity of the hood.
• Use only smooth pipelines or flexible
hoses of non-flammable materials for
the exhaust air pipeline
• If the exhaust air pipeline is horizon-
tally routed, there must be a minimum
gradient of 1 cm per metre or an inc-
lination angle of 2°. (Fig. C) Otherwise
condensation water could run into the
extractor hood motor.
• If the exhaust air is directed into an
exhaust air duct, the end of the entry
fitting must be directed in the direc-
tion of flow.
• If the exhaust air pipeline is routed
though cool rooms, lofts etc. there can
be a large temperature drop within
the individual parts of the pipeline,
resulting in sweating or condensation
water production. This renders outlet
pipeline insulation necessary.
• In some cases a condensation water
barrier must be installed in addition
to adequate insulation
The manufacturer is constantly engaged
in the further improvement of his pro-
ducts. Please note that products are sub-
ject to changes in form, equipment and
the applied technology.
The manufacturer is not responsible for
any faults occurring through non-com-
pliance with the above information and
provisions.
1
2
!
3
EN
Содержание TEL440ED
Страница 1: ...Version 1 0 141126 DE Bedienungsanleitung f r Ihre Dunstabzugshaube Modell TEL440ED BASI C LINE...
Страница 20: ...Version 1 0 140922 W nscht Ihnen viel Freude beim Kochen Vielen Dank f rs Lesen...
Страница 21: ...BASI C LINE Version 1 1 141006 EN User s manual for your cooker hood Model TEL440ED...
Страница 40: ...We wish you much success with the appliance Version 1 1 140918...