9
Dryer gas pipe
■
The gas pipe that comes out through the rear of your dryer
has a
³⁄₈
" male pipe thread.
*NOTE: If the dryer is mounted on a pedestal, the gas pipe height
must be an additional 11" (28 cm) from the floor. For a garage
installation, the gas pipe height must be an additional
18" (46 cm) from the floor.
Venting Requirements
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.
If using an existing vent system
■
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
■
Replace any plastic or metal foil vent with rigid metal vent.
■
Review Vent system charts. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
■
Use a heavy metal vent. Do not use plastic or metal foil vent.
■
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
DURASAFE™ vent products can be purchased from your
dealer or by calling Whirlpool Parts and Accessories. For
more information, see the “Assistance or Service” section of
this manual.
Rigid metal vent
■
For best drying performance, rigid metal vents are
recommended.
■
Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
■
Flexible metal vents are acceptable only if accessible for
cleaning and the total length does not exceed 8 ft (2.4 m).
■
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
■
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
■
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Clamps
■
Use clamps to seal all joints.
■
Exhaust vent must not be connected or secured with screws
or other fastening devices that extend into the interior of the
duct. Do not use duct tape.
A. ½" NPT gas supply line
B
.
³⁄₈
" NPT dryer pipe
A
B
4"
(12.3 cm)
2
¹³⁄₁₆
"*
(7.1 cm)
WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
4" (10.2 cm) heavy metal exhaust vent
Good
Better
Clamp
4"
10.2 cm