2-6
n
Built-In Single and Double Wall Ovens
OPERATION
Oven Appliance Manager
Below is the Applaince Manager showing relay locations. If you compare the wiring diagrams from the
previous pages and the appliance manager pinouts below you can see how the board and the wiring
diagram come together.
• P1 Terminal - connection from the User Interface Assembly
• P3 Terminal - LOGIC Circuits to the Appliance Manager
• P5 Terminal - 120 VAC circuits that operate through the K4 - K8 relays
• J8 Terminal - 120 VAC power source into board from house power supply
• P4, P6 and P7 terminals not used on this oven
• K1, K2, K6, and K9 - relays not used on this oven
Содержание KOCE500ESS
Страница 14: ...1 10 n Built In Single and Double Wall Ovens GENERAL INFORMATION NOTES ...
Страница 24: ...2 10 n Built In Single and Double Wall Ovens OPERATION NOTES ...
Страница 27: ...ELECTRONIC CONTROL DIAGNOSTIC MODE AND COMPONENT TESTING Built In Single and Double Wall Oven n 3 3 Safety ...
Страница 34: ...3 10 n Built In Single and Double Wall Oven ELECTRONIC CONTROL DIAGNOSTIC MODE AND COMPONENT TESTING NOTES ...
Страница 44: ...4 10 n Built InSingle and Double Wall Ovens COMPONENT ACCESS NOTES ...