COMPONENT ACCESS
Built-In Single and Double Wall Ovens
n
4-3
REMOVING THE EXHAUST BLOWER
MOTOR AND FAN ASSEMBLY
Double oven will have both appliance manager
boards at this location. Upper oven control is
on the right and the lower oven control is on the
left side.
Single oven will have one appliance manager
board.
Remove electrical connections and remove 2
mounting screws on the left side of the board.
Pull board to the left to release two mounting
tabs on the right side of the board.
The oven will need to be completely removed from
the cabinet. Remove the top control service
covers.
Remove the mounting screws and remove both
covers.
The back service cover (behind the oven) will need
to be removed. Locate the mounting screws
and remove the cover.
The blower motor and fan assembly is now
completely exposed. Remove the electrical
connection to the motor. Remove two Blower
Assembly mounting screws from each side of
the assembly and remove the assembly.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Failure to do so can result in death or
electrical shock.
Replace all parts and panels before operating.
Содержание KOCE500ESS
Страница 14: ...1 10 n Built In Single and Double Wall Ovens GENERAL INFORMATION NOTES ...
Страница 24: ...2 10 n Built In Single and Double Wall Ovens OPERATION NOTES ...
Страница 27: ...ELECTRONIC CONTROL DIAGNOSTIC MODE AND COMPONENT TESTING Built In Single and Double Wall Oven n 3 3 Safety ...
Страница 34: ...3 10 n Built In Single and Double Wall Oven ELECTRONIC CONTROL DIAGNOSTIC MODE AND COMPONENT TESTING NOTES ...
Страница 44: ...4 10 n Built InSingle and Double Wall Ovens COMPONENT ACCESS NOTES ...
Страница 52: ......