INSTALLATION INSTRUCTIONS

Remove Mounting Plate

NOTE: 

To avoid possible damage to the work surface, cover the 

work surface.

1.

Remove any remaining contents from the microwave oven 
cavity.

2.

Remove the mounting plate by peeling off the strips of tape 
that attach it to the back of the microwave oven, and set the 
mounting plate aside.

3.

Tape the microwave oven door closed so that door does not 
swing open while the microwave oven is being handled.

NOTE:

 To avoid damage to the microwave oven, do not grip or 

use the door or door handle while the microwave oven is being 
handled.

Convert Microwave Oven to 

External Venting

(for wall or roof venting only)

The microwave oven is set for recirculation installation. For wall or 
roof venting, changes must be made to the venting system. See 
“Venting Design Specifications” section.

NOTE:

 Skip this section if you are using recirculation installation. 

Keep the damper assembly in case the venting method is 
changed, or the microwave oven is reinstalled in another location 
where wall or roof venting may be used.
To prepare the microwave oven for wall or roof venting, the vent 
deflector (L-shaped metal bar) must be installed, and the 
appropriate damper vent opening must be uncovered.

To Install Vent Deflector:

1.

Gently pull the rings and lift vent screen from the top of the 
microwave oven.

2.

With vent deflector oriented as shown (wide side down), slide 
it back and under the back edge of the vent opening.

A. Mounting plate
B. Back of microwave oven

C. Tape (multiple locations)

A                     B                         C

A. Top of microwave oven
B. Vent screen

C. Rings

A. Vent opening
B. Vent deflector

B                   C

A

A              B

Содержание KHMS2050SSS - 30" Microwave Hood Combo

Страница 1: ...r Wall 7 Attach Mounting Plate to Wall 8 Prepare Upper Cabinet 8 Install the Microwave Oven 9 Complete Installation 10 VENTING DESIGN SPECIFICATIONS 11 ASSISTANCE 12 Replacement Parts 12 W10189714A You can be killed or seriously injured if you don t immediately You can be killed or seriously injured if you don t follow All safety messages will tell you what the potential hazard is tell you how to ...

Страница 2: ...r builder or cabinet supplier to make sure that the materials used will not discolor delaminate or sustain other damages For gas cooktop we recommend that combined cooking surface rating does not exceed 55 000 BTU hr The microwave oven is set for recirculation mode For external wall or roof venting see Venting Design Specifications section Special Requirements For Wall Venting Installation Only Cu...

Страница 3: ...round prong Do not use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock WARNING GROUNDING INSTRUCTIONS SAVE THESE INSTRUCTIONS For all cord connected appliances The microwave oven must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the elect...

Страница 4: ...ion For wall or roof venting changes must be made to the venting system See Venting Design Specifications section NOTE Skip this section if you are using recirculation installation Keep the damper assembly in case the venting method is changed or the microwave oven is reinstalled in another location where wall or roof venting may be used To prepare the microwave oven for wall or roof venting the v...

Страница 5: ... 4 Position the damper assembly so that the long tab slides into the slot on the right side of the damper vent opening as shown Then secure with mounting screw Roof Venting Installation Only To Remove Roof Damper Vent Cover 1 Locate the roof damper vent cover on the top of the microwave oven 2 Using diagonal wire cutting pliers gently snip out the damper vent cover at the perforations 3 Save the c...

Страница 6: ...e mounting plate No Wall Studs at Corner Holes Figure 1 No Wall Studs at Corner Holes Figure 2 NOTE If wall stud is within 6 15 2 cm of the vertical centerline see Mark Rear Wall section only recirculation or roof venting installation can be done Wall Stud at One Corner Hole Figure 3 Wall Studs at Both Corner Holes Figure 4 A Corner holes on mounting plate B Cabinet opening vertical centerline C W...

Страница 7: ...omplete the 12 x 4 30 5 x 10 2 cm rectangle This is the venting cutout area 11 Cut a 3 4 19 mm hole in one corner of the cutout area 12 Using a keyhole saw cut out the venting cutout area DrillHolesinRearWall In addition to being installed on at least 1 wall stud the mounting plate must attach to the wall at both bottom corner holes If the holes are not over wall studs use two 1 4 20 x 3 round hea...

Страница 8: ...t to go through the wall and to open 3 Position mounting plate on the wall making sure that the top of the mounting plate is aligned with the front edge of the upper cabinet 4 Push the bolt with toggle nut through the drywall and finger tighten the bolt to make sure toggle nut has opened against drywall 5 Insert a lag screw into the remaining bottom corner hole 6 If installing on a second wall stu...

Страница 9: ...in the bottom of the upper cabinet 5 Rotate microwave oven up toward upper cabinet NOTE If venting through the wall make sure the damper assembly fits easily into the vent in the wall cutout 6 Push microwave oven against mounting plate and hold in place NOTE If microwave oven does not need to be adjusted skip steps 7 9 7 If adjustment is required rotate microwave oven downward Using 2 or more peop...

Страница 10: ...e of 1 minute at 100 power Test vent fan and exhaust by operating the vent fan 5 If the microwave oven does not operate Check that a household fuse has not blown or that a circuit breaker has not tripped Replace the fuse or reset the circuit breaker If the problem continues call an electrician Check that the power supply cord is plugged into a grounded 3 prong outlet See the Use and Care Guide for...

Страница 11: ...amper to open fully If venting through the roof and rectangular to round transition is used be sure there is at least 3 7 6 cm of clearance between the top of the microwave oven and the transition piece See Rectangular to Round Transition illustration Rectangular to Round Transition NOTE The minimum 3 7 6 cm clearance must exist between the top of the microwave oven and the rectangular to round tr...

Страница 12: ...e oven model number and serial number Both numbers can be found on the model and serial number plate which is located behind the microwave oven door on the front frame of the microwave oven If you need additional assistance call us at our toll free number or visit our website listed in the Use and Care Guide ReplacementParts If any of the installation hardware needs to be replaced call us at our t...