14
Injectors table
COUNTRIES: BE - FR - CATEGORY II2E+3+
ELECTRICAL SUPPLY: 230 V ~ 50 Hz
Type of gas used
Type of
burner
Injector
marking
Primary air
adjustment
(X) (mm)
Rated
thermal flow
rate (kW)
Rated
consumption
Reduced heating capacity
(kW)
Gas pressure (mbar)
BE
FR
min.
rat.
max.
NATURAL GAS
(Methane))
G20
17
20
25
rapid
128
–
3,00
286 l/h
0,80
0,60
semi-rapid
95
–
1,65
157 l/h
0,45
0,35
LIQUEFIED
PETROLEUM GAS
(Butane)
G30
20
28-30
35
rapid
87
–
3,00
218 g/h
0,60
0,60
semi-rapid
67
–
1,65
120 g/h
0,35
0,35
LIQUEFIED
PETROLEUM GAS
(Propane)
G31
25
37
45
rapid
87
–
3,00
214 g/h
0,60
0,60
semi-rapid
67
–
1,65
118 g/h
0,35
0,35
Type of gas used
Model configuration
Nominal heating capacity (kW)
Total rated consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20
20 mbar
2 burners
4,65
443 l/h
9,52
G30
28-30 mbar
2 burners
4,65
338 g/h
30,94
G31
37 mbar
2 burners
4,65
332 g/h
23,80
COUNTRIES: ES - GB - IT - CATEGORY II2H3+
ELECTRICAL SUPPLY: 230 V ~ 50 Hz
Type of gas used
Type of burner
Injector
marking
Primary air
adjustment
(X) (mm)
Nominal
heating
capacity (kW)
Rated
consumption
Reduced
heating
capacity (kW)
Gas pressure (mbar)
min.
rat.
max.
NATURAL GAS
(Methane)
G20
17
20
25
rapid
128
–
3,00
286 l/h
0,60
semi-rapid
95
–
1,65
157 l/h
0,35
LIQUEFIED PETROLEUM
GAS (Butane)
G30
20
28-30
35
rapid
87
–
3,00
218 g/h
0,60
semi-rapid
67
–
1,65
120 g/h
0,35
LIQUEFIED PETROLEUM
GAS (Propane)
G31
25
37
45
rapid
87
–
3,00
214 g/h
0,60
semi-rapid
67
–
1,65
118 g/h
0,35
Type of gas used
Model configuration
Nominal heating capacity (kW)
Total rated consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20
20 mbar
2 burners
4,65
443 l/h
9,52
G30
28-30 mbar
2 burners
4,65
338 g/h
30,94
G31
37 mbar
2 burners
4,65
332 g/h
23,80