background image

14

Injectors table

COUNTRIES: BE - FR     -     CATEGORY II2E+3+

ELECTRICAL SUPPLY: 230 V ~ 50 Hz

Type of gas used

Type of

burner

Injector

marking 

Primary air
adjustment

(X) (mm)

Rated

thermal flow

rate (kW)

Rated

consumption

Reduced heating capacity

(kW)

Gas pressure (mbar)

BE

FR

min.

rat.

max.

NATURAL GAS

(Methane)) 

G20

17

20

25

rapid

128

3,00

286 l/h

0,80

0,60

semi-rapid

95

1,65

157 l/h

0,45

0,35

LIQUEFIED

PETROLEUM GAS

(Butane) 

G30

20

28-30

35

rapid

87

3,00

218 g/h

0,60

0,60

semi-rapid

67

1,65

120 g/h

0,35

0,35

LIQUEFIED

PETROLEUM GAS

(Propane) 

G31

25

37

45

rapid

87

3,00

214 g/h

0,60

0,60

semi-rapid

67

1,65

118 g/h

0,35

0,35

Type of gas used

Model configuration

Nominal heating capacity (kW)

Total rated consumption

Air necessary (m

3

) for the

combustion of 1 m

3

of gas

G20

20 mbar

2 burners

4,65

443 l/h

9,52

G30

28-30 mbar

2 burners

4,65

338 g/h

30,94

G31

37 mbar

2 burners

4,65

332 g/h

23,80

COUNTRIES: ES - GB - IT     -     CATEGORY II2H3+

ELECTRICAL SUPPLY: 230 V ~ 50 Hz

Type of gas used

Type of burner

Injector

marking 

Primary air
adjustment

(X) (mm)

Nominal

heating

capacity (kW)

Rated

consumption

Reduced

heating

capacity (kW)

Gas pressure (mbar)

min.

rat.

max.

NATURAL GAS

(Methane) 

G20

17

20

25

rapid

128

3,00

286 l/h

0,60

semi-rapid

95

1,65

157 l/h

0,35

LIQUEFIED PETROLEUM

GAS (Butane) 

G30

20

28-30

35

rapid

87

3,00

218 g/h

0,60

semi-rapid

67

1,65

120 g/h

0,35

LIQUEFIED PETROLEUM

GAS (Propane) 

G31

25

37

45

rapid

87

3,00

214 g/h

0,60

semi-rapid

67

1,65

118 g/h

0,35

Type of gas used

Model configuration

Nominal heating capacity (kW)

Total rated consumption

Air necessary (m

3

) for the

combustion of 1 m

3

of gas

G20

20 mbar

2 burners

4,65

443 l/h

9,52

G30

28-30 mbar

2 burners

4,65

338 g/h

30,94

G31

37 mbar

2 burners

4,65

332 g/h

23,80

Содержание KHDD 3020

Страница 1: ...Instructions for use GB ...

Страница 2: ......

Страница 3: ...r table in the instructions booklet for the specific type 9 Adjusting minimum setting of taps 9 After Sales Service 10 Troubleshooting guide 10 Care and maintenance 11 Routine cleaning and maintenance 11 EC Declaration of conformity 11 Safeguarding the environment 12 Product description 12 Lighting the burners 12 Practical advice for using the burners 13 Dimensions and distances to be maintained m...

Страница 4: ...ms only The electrical and gas connections must comply with local regulations When installing the hob fit a single pole disconnect switch with a minimum contact gap of 3 mm which allows complete disconnection of the appliance Regulations require that the appliance is earthed The power cable must be long enough for connecting the appliance once fitted in its housing to the power supply Use only fle...

Страница 5: ...nearest After sales Service TECHNICAL INFORMATION FOR THE INSTALLER This product can be embedded in a worktop 20 to 60 mm thick If there is no oven beneath the hob insert a separator panel which is at least equal in size to the opening made in the worktop This panel must be positioned at a maximum distance of 150 mm below the upper surface of the work surface but in no case less than 20 mm from th...

Страница 6: ...tions The maximum length of the steel hose is 2 linear metres A Gas supply B Gas hob manifold IMPORTANT if a stainless steel hose is used it must be installed so as not to touch any mobile part of the furniture It must pass through an area free from obstructions and permit inspection along the entire length After connection to the gas supply check for leaks with soapy water Light up the burners an...

Страница 7: ...ktop fig 2 Carry out the following operations Place the hob on top of the milled surface and using the screws and fixing brackets supplied secure the hob to the support structure ensuring it is perfectly level Carefully trim any excess from the edge of the gasket For installation in wooden worktops especially chipboard if there is even the slightest gap between the milled surface and the edge of t...

Страница 8: ... kitchen worktops with a depth between 35 mm 60 mm Fit the brackets into the relevant bores on the bottom of the hob and fasten using the screws supplied C as shown in the following diagrams 8 A B C IMPORTANT the power supply cable must be long enough to allow the hob to be lifted upwards for removal from the worktop ...

Страница 9: ...ed Light up the burners and turn the knobs from max position to minimum position to check flame stability Upon completion of adjustment reseal using sealing wax or an equivalent material Adjusting minimum setting of taps This operation must be performed by a qualified technician If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and on the sti...

Страница 10: ...thermocouple the end of the safety device is not dirty the minimum gas setting is correct see relevant paragraph 3 Pots pans wobble or are unsteady Check that the bottom of the pot or pan is perfectly flat the pot or pan is centered on the burner the panstand grids have not been swapped over or positioned incorrectly If after the above checks the fault persists get in touch with the nearest After ...

Страница 11: ...on device do not use it when the burners are not in their housing Routine cleaning and maintenance Before any cleaning and or maintenance operation disconnect the hob from power supply and wait until it is cold To keep the hob in perfect condition remove any food residue and clean it after every use Hob cleaning Clean the surfaces of the hob with lukewarm water and or neutral detergent rinse and d...

Страница 12: ...this case repeat the operations described above In the event of a burner flame being accidentally extinguished turn off the burner and wait at least one minute before attempting to ignite it again Lighting the burners Disposing of packaging The packing material is 100 recyclable and is marked with the recycle symbol The various parts of the packing must not be sent for waste but recycled in confor...

Страница 13: ...s see table on the right Only use flat bottomed pots and pans Use the correct amount of water for cooking foods and keep the pot covered NOTE Do not use pots with a larger than recommended diameter Because of the flush mounted design of these hobs the use of pots or pans with a larger than recommended diameter could cause discolouring of the stainless steel due to the high working temperatures rea...

Страница 14: ...s G20 20 mbar 2 burners 4 65 443 l h 9 52 G30 28 30 mbar 2 burners 4 65 338 g h 30 94 G31 37 mbar 2 burners 4 65 332 g h 23 80 COUNTRIES ES GB IT CATEGORY II2H3 ELECTRICAL SUPPLY 230 V 50 Hz Type of gas used Type of burner Injector marking Primary air adjustment X mm Nominal heating capacity kW Rated consumption Reduced heating capacity kW Gas pressure mbar min rat max NATURAL GAS Methane G20 17 2...

Страница 15: ...re mbar min rat max NATURAL GAS Methane G20 17 20 25 rapid 128 3 00 286 l h 0 60 semi rapid 95 1 65 157 l h 0 35 LIQUEFIED PETROLEUM GAS Butane G30 Propane G31 25 30 35 rapid 87 3 00 218 g h 0 60 semi rapid 67 1 65 120 g h 0 35 Type of gas used Model configuration Nominal heating capacity kW Total rated consumption Air necessary m3 for the combustion of 1 m3 of gas G20 20 mbar 2 burners 4 65 443 l...

Страница 16: ...5019 704 02023 Printed in Italy n 11 10 GB Whirlpool Europe S r l Viale G Borghi 27 21025 Comerio VA Phone 0332 759111 Fax 0332 759268 www whirlpool eu ...