15
Injectors table
COUNTRIES: DK - FI - NO - SE - CATEGORY II2H3B/P
ELECTRICAL SUPPLY: 230 V ~ 50 Hz
Type of gas used
Type of burner
Injector
marking
Primary air
adjustment
(X) (mm)
Nominal
heating
capacity (kW)
Rated
consumption
Reduced
heating
capacity (kW)
Gas pressure (mbar)
min.
rat.
max.
NATURAL GAS
(Methane)
G20
17
20
25
rapid
128
–
3,00
286 l/h
0,60
semi-rapid
95
–
1,65
157 l/h
0,35
LIQUEFIED PETROLEUM
GAS (Butane)
G30
(Propane)
G31
25
30
35
rapid
87
–
3,00
218 g/h
0,60
semi-rapid
67
–
1,65
120 g/h
0,35
Type of gas used
Model configuration
Nominal heating capacity (kW)
Total rated consumption
Air necessary (m
3
) for the
combustion of 1 m
3
of gas
G20
20 mbar
2 burners
4,65
443 l/h
9,52
G30-G31
30 mbar
2 burners
4,65
338 g/h
30,94