background image

3

Location Requirements

IMPORTANT:

 Observe all governing codes and ordinances. Do 

not obstruct flow of combustion and ventilation air.

 

It is the installer’s responsibility to comply with installation 

clearances specified on the model/serial/rating plate. The 

model/serial/rating plate is located on the underside of the 

cooktop burner box.

 

To eliminate the risk of burns or fire by reaching over the 

heated surface units, cabinet storage space located above 

the surface units should be avoided. If cabinet storage is to 

be provided, the risk can be reduced by installing a range 

hood that projects horizontally a minimum of 5" (12.7 cm) 

beyond the bottom of the cabinets.

 

All openings in the wall or floor where cooktop is to be 

installed must be sealed.

 

Cabinet opening dimensions that are shown must be used. 

Given dimensions are minimum clearances.

 

Grounded electrical supply is required. See “Electrical 

Requirements” section.

 

Proper gas supply connection must be available. See “Gas 

Supply Requirements” section.

 

The cooktop is designed to hang from the countertop by its 

side or rear flanges.

 

The gas and electric supply should be located as shown in 

“Cabinet Requirements” section so that they are accessible 

without requiring removal of the cooktop.

 

Provide cutout in right rear corner of cutout enclosure as 

shown to provide clearance for gas inlet and power supply 

cord, and to allow the rating label to be visible.

 

Ovens approved for this type of installation will have an 

approval label located on the top of the oven. If you do 

not find this label, contact your dealer to confirm that your 

oven is approved. Refer to oven manufacturer’s Installation 

Instructions for approval for built-in undercounter use and 

proper cutout dimensions.

IMPORTANT:

 To avoid damage to your cabinets, check with 

your builder or cabinet supplier to make sure that the materials 

used will not discolor, delaminate or sustain other damage.

Mobile Home - Additional Installation Requirements

The installation of this cooktop must conform to the 

Manufactured Home Construction and Safety Standard, Title 24 

CFR, Part 3280 (formerly the Federal Standard for Mobile Home 

Construction and Safety, Title 24, HUD Part 280). When such 

standard is not applicable, use the Standard for Manufactured 

Home Installations, ANSI A225.1/NFPA 501A or with local codes. 
In Canada, the installation of this cooktop must conform with the 

current standards CAN/CSA-A240-latest edition, or local codes. 

Product Dimensions

Cabinet Requirements

IMPORTANT:

 If installing a range hood or microwave hood 

combination above the range, follow the range hood or 

microwave hood combination installation instructions for 

dimensional clearances above the cooktop surface.

NOTES:

 After making the countertop cutout, some installations 

may require notching down the base cabinet side walls to clear 

the burner box. To avoid this modification, use a base cabinet 

with sidewalls wider than the cutout.
If cabinet has a drawer, a 4" (10.2 cm) depth clearance from the 

countertop to the top of the drawer (or other obstruction) in base 

cabinet is required. The drawer depth may need to be shortened 

to avoid interfering with the regulator.

A

B

C

A. 23

1

/

4

" (59 cm)

B. 20

5

/

64

" (51 cm)

C. 1

1

/

2

" (3.8 cm)

C

B

A

E

F

H

I

G

K

L

D

J

A.  24" (61 cm) minimum - 26" (68 cm) maximum 

distance between overhead cabinets

B.  13" (33 cm) minimum recommended upper cabinet depth
C.  30" (75 cm) minimum combustible area above countertop 

(shown by dashed box above)

D. 18

29

/

32

" (48 cm)

E.  Grounded outlet - Locate within 24" (61 cm) 

of right rear corner of cutout.

F. 22

3

/

64

" (56 cm)

G. Gas line opening - 

Wall: anywhere 5" (12.7 cm) below underside of countertop. 

Cabinet floor: anywhere within 6" (15.2 cm) of rear wall 

is recommended.

H.  4" (10 cm) minimum distance to nearest left and right side 

combustible surface

I. 2

7

/

8

" (7 cm) minimum distance to rear combustible surface

J. 20

1

/

2

" (52 cm) minimum clearance from upper cabinet to 

countertop within minimum horizontal clearances to cooktop

K.  30" (76.2 cm) minimum clearance between top of cooktop 

platform and bottom of uncovered wood or metal cabinet 

(24" [61 cm] minimum clearance if bottom of wood or 

metal cabinet is covered by not less than 

1

/

4

" [0.6 cm] flame 

retardant millboard covered with not less than No. 28 MSG 

sheet steel, 0.015" [0.04 cm] stainless steel, or 0.024" 

[0.06 cm] aluminum or 0.020" [0.05 cm] copper)

L. 25

5

/

8

" (65.09 cm) minimum countertop depth is required.

Содержание KGCK346BSS

Страница 1: ...afety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W10837635A IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation...

Страница 2: ...lectrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that...

Страница 3: ...24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 When such standard is not applicable use the Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A or with local codes In Canada the installation of this cooktop must conform with the current standards CAN CSA A240 latest edition or local codes Product Dimensions Cabinet Requir...

Страница 4: ...gas see the Gas Conversion instructions provided in the package containing literature The model serial rating plate located on the right center underside of the burner box has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP Gas conversion Conversion must be done by a qualified service technici...

Страница 5: ...n on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada Gas Supply Pressure Testing Line pressure testing above 1 2 psi gauge 14 WCP The appliance and its individual shutoff valve must be disconnected from the gas supply piping system dur...

Страница 6: ...TE Do not overtighten the screw and bend the bracket 4 Repeat steps 1 through 3 and install clamping brackets in the remaining corners of the cooktop Bracket installation for 11 8 2 30 50 mm thick countertops 1 Position a clamping bracket as shown 2 Insert the tab on the clamping bracket into the slot in the cooktop in the right front corner of the cooktop as shown 3 Insert a 1 2 5 cm clamping scr...

Страница 7: ...Tighten both adapters and nipples 3 Use a 15 16 combination wrench and pliers to attach the flexible connector to the adapters Check that connector is not kinked Complete Connection 1 Open the manual shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe 2 Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will s...

Страница 8: ...o not light properly Turn surface burner control knob to OFF Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown Check that the gas shutoff valves are set to the Open position Check that burner caps are properly positioned on burner bases Recheck operation of surface burners If a burner does not light at this point turn control knobs to OFF and ...

Страница 9: ... décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du télép...

Страница 10: ...n est retenue sur le plan de travail par ses rebords latéraux ou arrière Veiller à placer les alimentations en gaz et électricité selon les indications de la section Spécifications du placard pour qu elles soient accessibles sans avoir à retirer la table de cuisson Prévoir une ouverture dans le panneau arrière du placard à droite voir l illustration pour le passage de la canalisation de gaz et du ...

Страница 11: ... cet appareil Les systèmes d allumage électronique fonctionnent avec des limites de tension étendues mais une liaison à la terre correcte et une polarité appropriée sont nécessaires Vérifier que la prise fournit une alimentation de 120 V et qu elle est correctement reliée à la terre Les schémas de câblage sont fournis avec cette cuisinière Voir la section Schémas de câblage C B A E F H I G K L D J...

Страница 12: ...s utiliser de ruban TEFLON Pour l alimentation au propane le diamètre des canalisations doit être de 1 2 au minimum En général le fournisseur de gaz propane détermine les matériaux à utiliser et le diamètre approprié Raccord métallique flexible Si les codes locaux le permettent utiliser un connecteur à gaz flexible en acier inoxydable de 1 2 ou 3 4 de diamètre interne conçu par CSA pour raccorder ...

Страница 13: ...lé des canalisations d alimentation en gaz par la fermeture du robinet d arrêt manuel individuel durant tout test de pressurisation de la canalisation de gaz à une pression inférieure ou égale à 1 2 lb po 3 5 kPa INSTRUCTIONS D INSTALLATION Préparation de la table de cuisson Déterminer l emplacement final de la table de cuisson 1 Placer la table de cuisson à l envers sur une surface de travail cou...

Страница 14: ...ment au gaz Assemblage du détendeur 1 Placer la table de cuisson en appui sur le côté ou la face arrière avec l aide de deux personnes ou plus 2 Connecter le raccord flexible d acier inoxydable au détendeur utiliser un raccord droit et un raccord d adaptation comportant un filetage mâle de 1 2 A A Vis de fixation de 1 2 5 cm B A A Fente B Patte A A Vis de fixation de 1 2 5 cm AVERTISSEMENT Risque ...

Страница 15: ...ur fixer le raccord flexible sur les raccords d adaptation Vérifier que le raccord n est pas déformé Compléter le raccordement 1 Ouvrir le robinet d arrêt manuel sur la canalisation de gaz Le robinet est ouvert lorsque la manette est parallèle à la canalisation 2 Vérifier tous les raccordements en les badigeonnant d une solution de détection des fuites non corrosive approuvée L apparition de bulle...

Страница 16: ...r les boutons de commande à OFF arrêt Si les brûleurs ne s allument pas correctement Ramener le bouton de commande des brûleurs de surface à la position OFF arrêt Vérifier que le cordon d alimentation est branché que le disjoncteur ne s est pas déclenché et qu aucun fusible n a grillé Vérifier que chaque robinet d arrêt est ouvert Vérifier que le chapeau de brûleur est correctement placé sur la ba...

Отзывы: