INSTALLATION REQUIREMENTS

Tools and Parts

Gather the required tools and parts before starting installation.

Tools needed

 

Tape measure

 

Flat-blade screwdriver

 

15

/

16

" combination wrench

 

Pipe wrench

 

Pliers

 

Level

 

Phillips screwdriver

 

Marker or pencil

 

Pipe-joint compound resistant to LP gas

 

Noncorrosive leak-detection solution

Parts supplied

 

Gas pressure regulator

 

Burner grates (2 or 4 depending on model)

 

Burner caps (4)

 

Clamping brackets (4)

 

1" (2.5 cm) clamping screws (4)

Parts needed

Check local codes and consult gas supplier. Check existing gas 

supply and electrical supply. See “Electrical Requirements” and 

“Gas Supply Requirements” sections.

WARNING: If the information in this manual is not followed exactly, a fire or explosion 
may result causing property damage, personal injury or death.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this 
or any other appliance.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's 
instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or 
the gas supplier.

WARNING: 

Gas leaks cannot always be detected by smell.

Gas suppliers recommend that you use a gas detector approved by UL or CSA.
For more information, contact your gas supplier.
If a gas leak is detected, follow the “What to do if you smell gas” instructions.

IMPORTANT: Do not install a ventilation system that blows air downward toward this gas cooking appliance. This type of 
ventilation system may cause ignition and combustion problems with this gas cooking appliance resulting in personal injury or 
unintended operation.

In the State of Massachusetts, the following installation instructions apply:

■  

Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by 

the State of Massachusetts.

■  

If using a ball valve, it shall be a T-handle type.

■  

A flexible gas connector, when used, must not exceed 3 feet.

Содержание KGCK346BSS

Страница 1: ...afety alert symbol and either the word DANGER or WARNING These words mean follow instructions instructions DANGER WARNING W10837635A IMPORTANT Installer Leave installation instructions with the homeowner Homeowner Keep installation instructions for future reference IMPORTANT Installateur Remettre les instructions d installation au propriétaire Propriétaire Conserver les instructions d installation...

Страница 2: ...lectrical switch Do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING Gas leaks cannot always be detected by smell Gas suppliers recommend that...

Страница 3: ...24 CFR Part 3280 formerly the Federal Standard for Mobile Home Construction and Safety Title 24 HUD Part 280 When such standard is not applicable use the Standard for Manufactured Home Installations ANSI A225 1 NFPA 501A or with local codes In Canada the installation of this cooktop must conform with the current standards CAN CSA A240 latest edition or local codes Product Dimensions Cabinet Requir...

Страница 4: ...gas see the Gas Conversion instructions provided in the package containing literature The model serial rating plate located on the right center underside of the burner box has information on the types of gas that can be used If the types of gas listed do not include the type of gas available check with the local gas supplier LP Gas conversion Conversion must be done by a qualified service technici...

Страница 5: ...n on the model serial rating plate are for elevations up to 2 000 ft 609 6 m For elevations above 2 000 ft 609 6 m ratings are reduced at a rate of 4 for each 1 000 ft 304 8 m above sea level not applicable for Canada Gas Supply Pressure Testing Line pressure testing above 1 2 psi gauge 14 WCP The appliance and its individual shutoff valve must be disconnected from the gas supply piping system dur...

Страница 6: ...TE Do not overtighten the screw and bend the bracket 4 Repeat steps 1 through 3 and install clamping brackets in the remaining corners of the cooktop Bracket installation for 11 8 2 30 50 mm thick countertops 1 Position a clamping bracket as shown 2 Insert the tab on the clamping bracket into the slot in the cooktop in the right front corner of the cooktop as shown 3 Insert a 1 2 5 cm clamping scr...

Страница 7: ...Tighten both adapters and nipples 3 Use a 15 16 combination wrench and pliers to attach the flexible connector to the adapters Check that connector is not kinked Complete Connection 1 Open the manual shutoff valve in the gas supply line The valve is open when the handle is parallel to the gas pipe 2 Test all connections by brushing on an approved noncorrosive leak detection solution Bubbles will s...

Страница 8: ...o not light properly Turn surface burner control knob to OFF Check that the power supply cord is plugged in and the circuit breaker has not tripped or the fuse blown Check that the gas shutoff valves are set to the Open position Check that burner caps are properly positioned on burner bases Recheck operation of surface burners If a burner does not light at this point turn control knobs to OFF and ...

Страница 9: ... décès Ne pas entreposer ni utiliser de l essence ou d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil électroménager QUE FAIRE DANS LE CAS D UNE ODEUR DE GAZ Ne pas tenter d allumer un appareil Ne pas toucher à un commutateur électrique Ne pas utiliser le téléphone se trouvant sur les lieux Appeler immédiatement le fournisseur de gaz à partir du télép...

Страница 10: ...n est retenue sur le plan de travail par ses rebords latéraux ou arrière Veiller à placer les alimentations en gaz et électricité selon les indications de la section Spécifications du placard pour qu elles soient accessibles sans avoir à retirer la table de cuisson Prévoir une ouverture dans le panneau arrière du placard à droite voir l illustration pour le passage de la canalisation de gaz et du ...

Страница 11: ... cet appareil Les systèmes d allumage électronique fonctionnent avec des limites de tension étendues mais une liaison à la terre correcte et une polarité appropriée sont nécessaires Vérifier que la prise fournit une alimentation de 120 V et qu elle est correctement reliée à la terre Les schémas de câblage sont fournis avec cette cuisinière Voir la section Schémas de câblage C B A E F H I G K L D J...

Страница 12: ...s utiliser de ruban TEFLON Pour l alimentation au propane le diamètre des canalisations doit être de 1 2 au minimum En général le fournisseur de gaz propane détermine les matériaux à utiliser et le diamètre approprié Raccord métallique flexible Si les codes locaux le permettent utiliser un connecteur à gaz flexible en acier inoxydable de 1 2 ou 3 4 de diamètre interne conçu par CSA pour raccorder ...

Страница 13: ...lé des canalisations d alimentation en gaz par la fermeture du robinet d arrêt manuel individuel durant tout test de pressurisation de la canalisation de gaz à une pression inférieure ou égale à 1 2 lb po 3 5 kPa INSTRUCTIONS D INSTALLATION Préparation de la table de cuisson Déterminer l emplacement final de la table de cuisson 1 Placer la table de cuisson à l envers sur une surface de travail cou...

Страница 14: ...ment au gaz Assemblage du détendeur 1 Placer la table de cuisson en appui sur le côté ou la face arrière avec l aide de deux personnes ou plus 2 Connecter le raccord flexible d acier inoxydable au détendeur utiliser un raccord droit et un raccord d adaptation comportant un filetage mâle de 1 2 A A Vis de fixation de 1 2 5 cm B A A Fente B Patte A A Vis de fixation de 1 2 5 cm AVERTISSEMENT Risque ...

Страница 15: ...ur fixer le raccord flexible sur les raccords d adaptation Vérifier que le raccord n est pas déformé Compléter le raccordement 1 Ouvrir le robinet d arrêt manuel sur la canalisation de gaz Le robinet est ouvert lorsque la manette est parallèle à la canalisation 2 Vérifier tous les raccordements en les badigeonnant d une solution de détection des fuites non corrosive approuvée L apparition de bulle...

Страница 16: ...r les boutons de commande à OFF arrêt Si les brûleurs ne s allument pas correctement Ramener le bouton de commande des brûleurs de surface à la position OFF arrêt Vérifier que le cordon d alimentation est branché que le disjoncteur ne s est pas déclenché et qu aucun fusible n a grillé Vérifier que chaque robinet d arrêt est ouvert Vérifier que le chapeau de brûleur est correctement placé sur la ba...