4-20
1.
Turn off gas supply and disconnect power
to the range.
2.
Pull the range out of its mounting location
so that you can access the rear of the unit.
3.
Remove the top and center braces and the
rear panel for the blower motor assembly
that you are servicing (see page 4-17 for
the procedures).
WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
Fire Hazard
Shut off gas supply line valve
before servicing.
Check all gas line connections
and replace all parts and panels
before operating.
Failure to do so can result in
explosion, fire or other injury.
REMOVING A BLOWER MOTOR ASSEMBLY
5.
Remove the four mounting screws and the
air vent screw from the blower motor as-
sembly and remove the assembly from
the range.
4
Remove the four screws from the blower
motor assembly cover and remove the
cover from the range.
Air Vent Screw
Blower Motor Assembly
Blower Motor Assembly
Cover Screws
Blower Motor Screws