4-4
REMOVING THE CONTROL PANEL AND COMPONENTS
WARNING
Electrical Shock Hazard
Disconnect power before
servicing.
Replace all parts and panels
before operating.
Failure to do so can result in
death or electrical shock.
Fire Hazard
Shut off gas supply line valve
before servicing.
Check all gas line connections
and replace all parts and panels
before operating.
Failure to do so can result in
explosion, fire or other injury.
1.
Turn off gas supply and disconnect power
to the range.
2.
Remove the grates from the range.
3.
To remove the control panel:
a) Pull the knobs off the gas valves, selec-
tor switches, and thermostats.
b) Remove the two indicated machine
screws from each bezel of the two
thermostats & selector switches.
NOTE:
The thermostat and selector switch for
each oven is an assembly, and is
mounted to the control panel with two
machine screws. Leave the remaining
bezel sheet-metal screws in place. It is
not necessary to remove them.
c) Lower the control panel so the six top
tabs are free of the slots and rotate it
forward and rest it on a small table.
Thermostat & Selector Switch
Assembly Machine Screw
The control panel components that are ser-
viced in this section consist of:
• Spark Modules
• Ignition Switches
• Gas Valves
• Clocks
• Thermostat & Selector Switch Assemblies
• Electronic Controls
• Cavity Light and Control Power Transform-
ers
Содержание KDRP487MSS - 48" Pro-Style Dual Fuel Range W
Страница 1: ...TECHNICAL EDUCATION JOB AID 4317355 KAC 38 48 Dual Fuel Slide In Range Model KDRP487MSS ...
Страница 10: ...1 6 NOTES ...
Страница 48: ...4 30 NOTES ...
Страница 56: ...5 8 NOTES ...
Страница 60: ...6 4 NOTES ...
Страница 65: ...7 5 NOTES ...
Страница 66: ...7 6 NOTES ...
Страница 68: ......