5-2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
CONVECTION RING ELEMENT
Refer to page 4-12 for the procedure for ac-
cessing the convection ring element.
1. Unplug oven or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads across wire
connector terminals. The meter should
indicate between 33 and 37
Ω
.
CONVECTION FAN MOTOR
Refer to page 4-13 for the procedure for ac-
cessing the convection fan motor.
1. Unplug oven or disconnect power.
2. Set the ohmmeter to the R x 1 scale.
3. Touch the ohmmeter test leads across wire
connector terminals. The meter should
indicate approximately 18
Ω
.