10
ENGLISH
INSTALLATION
INTRODUCTION ON INSTALLATION
Remember that:
•
the coocker must be installed by qualified staff
who can issue a Declaration of Conformity
•
all the local and national laws and the European
Standards must be met for installation and use of
the product.
•
In the event of installation in apartment blocks, ask
the administrator’s opinion beforehand.
The general instructions are provided below.
Checking the suitability of the installation
premises
•
The volume of the room must be over 19 m
3
KE 90
H14 ; 28 m
3
KE 90 H20
•
Installation is not permitted in bedrooms, bathro-
oms or premises with other products that take in
air for combustion of the same premises or in pre-
mises with an explosive atmosphere. Any extractor
fans, if working in the same environment or space
in which the product is installed, can cause draft
problems.
•
The floor must be able to support the weight of the
coocker and the accessories.
CHIMNEY SYSTEM
(Smoke channel, chimney flue and chimney
stack)
This chapter is drafted according to the European
Standards EN 13384, EN 1443, EN 1856, EN 1457. The
installation technicians must take into consideration
these and any other local standards. The manual
should in no way be considered a replacement for the
laws in force.
The coocker must be connected to a suitable smoke
discharge that guarantees completely safe evacuation
of the smoke produced by combustion.
Before positioning the coocker, you need to check the
chimney flue is suitable.
SMOKE CHANNEL, CHIMNEY FLUE
The smoke channel (pipe that connects the smoke
outlet of the fireplace with the chimney flue inlet) and the
chimney flue must, along with other legal provisions:
•
receive the discharge for a single product (multiple
product discharges are not permitted together)
•
have a mainly vertical development
•
no section should have a reserve slope
•
have an inner section preferably circular and
however with a ratio between sides lower than 1.5
•
complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
•
be created with materials with a fire reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
•
be appropriately certified, with an appropriate
fireplace plate, if metal
•
keep the initial section