For an alternate location, measure the free leg
between the top of the top X-brace or horizontal
brace and the beam supporting the vessel.
Figure 3-5. Vertical Location of Microcell™
Sets for Legs With Braces and with Free
Leg Greater Than 12 in (305mm).
See Figure 3-6. If the free leg distance is less than
12 in (305mm), mount the Microcell™ sets at the
mid-height between the lowest braces. When
mounting between the braces, insulation around
the adjacent braces is required for best
performance. This insulation will reduce the effect
of sun-induced stresses on the support metal.
Figure 3-6. Vertical Location of Microcell™
Sets for Legs With Braces and with Free
Leg Less Than 12 in (305mm).