TECHNICAL SPECIFICATIONS 

Products Code 

EQ900B 

HP 

6.5 hp 

CC 

190cc 

Engine Type 

 Strokes, Air cooled 

Max Auger RPM  

121 rpm 

Fuel Used 

Petrol 

Fuel Tank Capacity 

1000 ml 

Oil (Mixing) 

750 ml (20W 40 Grade) & Engine Oil should be changed 

initially after 10 Hrs afterwards once in every 50 hrs of engine 

run. 

Gear ratio 

30 

Lubricating oil 

20W40 

Weight of the 

Machine 

24 kg 

Consumption 

1hrs/650 ml (Engine) 

Work Capacity 

45 to 60 pits/1hrs(Out Put) 

Recommended 

Usage 

M/c can used to make pits 4", 6",8",10",12", 14" (Width) & 

24"(Depth) Only in agriculture land with 30% to 40% 

Moistures 

Note

:

 

Specifications are subject to change without prior notice. 

MAINTENANCE AND STORAGE 

AUGER MAINTENANCE

 

1.  The gear case has 4 oz. of grease installed at the factory. It is recommended that 

once a year the gear case be split and the grease level checked. Add grease only 

if level of grease is below top of the gears. 

DO NOT OVERFILL.

 

2.  Ensure all the screws, nuts, and bolts are tight. 

3.  During cold weather, store the unit in a cool environment. Transferring the unit 

from a warm to a cold place can cause the buildup of harmful condensation.  

4.  If blade performance decreases, turn unit off and disconnect spark plug wire. 

Carefully inspect cutting edge of blade for any signs of wear. If blades show any 
of these signs, they need to be sharpened or replaced

Содержание EQ9800

Страница 1: ...anual KisanKraft Machine Tools Pvt Ltd Sri Huchhanna Tower 4 1st Main 7 A Cross Maruthi Layout Dasarahalli HAF Post Hebbal Bangalore 560024 Karnataka INDIA Bangalore HO Ahmedabad Bhopal Bhubaneswar Co...

Страница 2: ...com info kisankraft com 91 80 22178200 Page 2of 20 CONTENTS BEFORE GETTING STARTED 3 SAFETY INSTRUCTIONS 3 OPERATION 6 STARTING AND STOPPING THE ENGINE 7 TECHNICAL SPECIFICATIONS 11 MAINTENANCE AND S...

Страница 3: ...servicing information Please read all the information carefully to avoid injury and machine damage NOTE General information is given throughout the manual that may help the operator in the operation o...

Страница 4: ...an engine in places where exhaust fumes may be pulled into a building Never run an engine in a poorly ventilated area where the exhaust fumes may be trapped and not easily taken away Examples include...

Страница 5: ...apors are highly explosive When storing screw down petrol cap vent screw tightly Never pour fuel from the engine fuel tank Never siphon fuel by mouth to drain the fuel tank Always have an adult fill t...

Страница 6: ...from the area around the fuel cap 4 Loosen fuel cap slowly Place the cap on a clean dry surface 5 Carefully add fuel without spilling 6 Do not fill the fuel tank completely full allow space for the f...

Страница 7: ...The fuel cap will not leak fuel during storage if the fuel cap is tight and the screw at the top is tight NOTE When storing unit in an upright position for pro longed periods of time in warm weather...

Страница 8: ...sound or the bang bang noise in case of overload operation which is normal If the continuous spark knock sound can still be heard when the gasoline engine operates under the normal load it is suggest...

Страница 9: ...ther than abruptly release the handle and allow it to rebound and strike the gasoline engine which will damage the starter It is required to quickly pull the starter or the electrode of the spark plug...

Страница 10: ...ps 1 Release the load firstly then press down the handle of the throttle valve to reduce the rotating speed of the gasoline engine 2 Press down the stop switch after 2 3 minutes of no load running CAU...

Страница 11: ...Depth Only in agriculture land with 30 to 40 Moistures Note Specifications are subject to change without prior notice MAINTENANCE AND STORAGE AUGER MAINTENANCE 1 The gear case has 4 oz of grease inst...

Страница 12: ...Every 3 months or 25 hours Every 6 months or 50 hours Every 1 year or 100 hours Every 2 years or 300 hours Lubricating oil Check the oil level Replacement Air filter Check Cleaning a Spark plug Check...

Страница 13: ...mpliance with environmental protection requirements It is suggested to store the waste lubricating oil into a sealed container and deliver it to the local waste oil recycle bin for treatment Do not th...

Страница 14: ...eeler gauge to measure the clearance of the spark plug If the adjustment is needed carry out the adjustment by bending the side electrode 5 Check whether the washer of the spark plug is in good condit...

Страница 15: ...center so as to prevent air from getting into the cylinder and rusting the cylinder 4 Wipe off the oil stain and dust on the external surface with the clean cotton yarn and remove the dirt between th...

Страница 16: ...el stabilizer according to manufacturer s instructions 2 Run the engine for 10 15 minutes to ensure that the stabilizer reaches the carburetor 3 Remove the remaining fuel from the fuel tank into an ap...

Страница 17: ...he recoil handle 6 Fuel line hose is not positioned in the bottom of the fuel tank 6 Push fuel line down into fuel in the fuel tank Engine runs rough 1 Dirty air filter 1 Clean or replace the air filt...

Страница 18: ...r replace the filter 3 Carburetor out of adjustment or bad 3 Call the service personnel Engine revs too high 1 Carburetor out of adjustment 1 Call the service personnel Auger turns at idle 1 Idle spee...

Страница 19: ...scopic Steel Pipe Fruit Picker Bag Sheep Shear GardenTools Electric Pressure Washer Hedge Trimmer Lawn Mower Electric Petrol Manual LeafBlower Cultivators and Accessories Petrol and Diesel Sprayers an...

Страница 20: ...ftTM www kisankraft com info kisankraft com 91 80 22178200 Page 20of 20 Wide Range of Products for Every Need For more information give MISSED CALL 07676065555 Many of our products have BIS ISI certif...