Page 8
Jump Start Cable’ port have enough energy present to cause a spark, creating an explosion
hazard, or to cause burns if a metal object contacts both terminals.
The following jump-start procedure is provided for your reference:
•
Turn OFF the vehicle or boat ignition and all accessories.
•
Engage the park or emergency brake and place the transmission in park for an automatic or
neutral for a manual vehicle.
•
If jump-starting a boat engine, purge the engine compartment and bilge of all fumes
•
Connect the ‘Heavy Duty Jump Start Cable’ to the ‘Heavy Duty DC Port’ located at the back of
the unit.
•
Position the unit on a flat, stable surface near the battery and away from all moving parts of the
engine.
•
Connect the red positive (+) clip of the cable to the positive (+) terminal of the engine battery.
•
Connect the black negative (-) clip of the cable to the engine black, cylinder head, or other
stationary heavy metal part of the motor, or to the negative (-) battery terminal.
•
Before starting the engine, make sure the unit and the cables are clear of belts and fans. Do not
crank the engine for more than 4 seconds.
•
Start the engine.
Warning: Fire hazard. The jump-start feature is designed for short term operation (less than 4
seconds) only. Operating the jump-start feature for more than 4 seconds may cause damage to
the unit or the clips. Allow the unit to cool down for at least 3 minutes after each jump-start.
•
After jump-start, remove the red positive (+) clip and then the black negative (-) clip from the
vehicle’s battery terminal.
•
Remove the cable from the Heavy Duty DC Port.
Important: Recharge the unit as soon as possible after each use.
Understanding the Warning/Fault Code
Error
Code
Condition Corrective
Action
E01
System senses battery voltage is low
and has shutdown the inverter.
Recharge battery immediately and restart
unit.
E02
System senses battery voltage is high
and has shutdown the inverter.
Check battery voltage or if any external high
voltage DC source is connected to ‘Lighter
Plug’ socket or the ‘Heavy Duty DC port.
E03
System AC output is overloaded or
short circuited and has shutdown.
Check load connected to AC output. Reduce
load and restart the unit.
E04
System senses high internal
temperature on the inverter and has
shutdown
Turn AC output power off. Wait for 15
minutes before restarting. Check if any
object is blocking the ventilation of unit.
E05
System warns battery voltage is low
and will shut down shortly
Recharge battery as soon as possible or
system will shut down shortly.
E06
Not used
Check load connected to AC output. Reduce
load.
E07
System warns of high internal
temperature and will shut down shortly.
Reduce load. Check if any object is blocking
the ventilation of unit.