Kisae Abso Charger 12V 100A Скачать руководство пользователя страница 8

 

 

Page 

 

 

 

 

Typical wiring block diagram of the Battery Charger with 3 battery banks 

 

AC Source:  

The charger accepts full universal input voltage (90-265Vac, 47-63Hz).

 

 

Branch Breaker:  

 

For use on 120V AC Input source, use a 15A branch breaker to connect between the AC Source 
and the charger AC Input hardwire cable (Hot

–black wire, Neutral–white wire, Ground–green 

wire). 
For use on 230V AC Input source, a minimum of 8A branch breaker is required from the AC 
Input Source.  

 

Battery Bank 1, 2 & 3:  

There are a total of three channels (CH1, CH2, CH3) available for charging three battery 
banks (Battery Bank 1, Battery Bank 2, Battery Bank 3). 

 

 

Chassis Ground: 

The unit chassis has to be grounded properly to the common ground point on the system.

 

 

Digital Remote (optional):  

The Display Remote (

Part Number

ACRM1202

) sold separately

 

is used to provide unit 

information from the charger. It is used as a secondary display to provide charger information. 
This can also be used as a main display or controller to connect two AC Chargers of the 
same model running in parallel. 

 

 

Battery Temperature Sensor 

– BTS (optional):  

The Battery Temperature Sensor BTS (

Part Number:

 

BTS-10K

) sold separately is designed 

to use on Battery Bank 1 (CH1) for better battery charging performance. The sensor is also 
used to terminate the battery charging process when it senses the battery temperature is 
either too high or too low and is not suitable for charging. 

 

 

 

Содержание Abso Charger 12V 100A

Страница 1: ...Abso Charger 12V 100A AC12100 24V 50A AC2450 Owner s Manual...

Страница 2: ...Page 2...

Страница 3: ...Abso Charger Misuse may result in damage to the unit and or cause harm or serious injury Product Numbers AC12100 Abso Charger 12V 100A AC2450 Abso Charger 24V 50A Document Part Number MU AC12100 Rev...

Страница 4: ...STALLING THE CHARGER 10 5 UNIT OPERATION 13 6 SPECIFICATIONS 19 7 WARRANTY 20 Appendix A1 GEL Flooded AGM Setting CH1 CH2 CH3 Appendix A2 1 Lithium Setting CH1 Appendix A2 2 Lithium Setting CH2 3 Appe...

Страница 5: ...an explosion WARNING Explosion hazard Do not use the unit in the vicinity of flammable fumes or gasses such as propane tanks or large engines Avoid covering the ventilation openings Always operate th...

Страница 6: ...ere is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning...

Страница 7: ...lgorithm During normal operation the charger will do a full charge cycle to float stage on Battery Bank 1 Once the float stage is reached the charger starts charging Battery Banks 2 and 3 together wit...

Страница 8: ...Battery Bank 3 Chassis Ground The unit chassis has to be grounded properly to the common ground point on the system Digital Remote optional The Display Remote Part Number ACRM1202 sold separately is...

Страница 9: ...e battery voltage reaches approximately 13 5V This timer is set to avoid battery overcharging The charger will override the Absorption to Float stage condition and goes to Float stage when it times ou...

Страница 10: ...he mounting template on the right to mark the positions of the mounting screws Drill the 4 mounting holes and place the Charger in position and fasten the unit to the mounting surface See mounting loc...

Страница 11: ...screws located at the top of the AC compartment cover Remove the top section of the AC Input wire strain relief located at the bottom of the base panel inside the AC wiring compartment by unscrewing t...

Страница 12: ...s Remote Port to the COM_2 port on the Remote Display Panel The Remote Display Panel is now ready to use Both charger displays will show CON indicating the chargers are connected in parallel And all...

Страница 13: ...display will then show the next menu to continue with other setting parameters NEXT Press the hold the key for longer than 5 seconds to RESET the charger Display will show RST and it will force the ch...

Страница 14: ...27 V 0 54V AGM 0 21 V 0 42V For use when Battery Temperature Sensor is in use No setting on the unit is required and the unit will automatically sense the Battery Temperature Sensor when it is connec...

Страница 15: ...rent L current in A Charging stages CH1 only Mode 2 Bulk and Absorption stage only Mode 3 Bulk Absorption and Float stage Battery temperature CH1 only Low Lo Normal nor High hi For Lithium battery typ...

Страница 16: ...ed channel first and follows with 1 hour of 15 5V equalization process Consult or follow the instruction as provided by the battery manufacturer on how to check the battery electrolyte level and or re...

Страница 17: ...g code will display The charger will recover automatically back to the maximum charging current when the environmental temperature drops to below 45 C Over Temperature Shutdown When the charger senses...

Страница 18: ...alled The unit will shut down The unit will automatically recover when the battery temperature has reduced to 60 C 140 F For Lithium battery type setting High battery temperature 60 C 140 F is sensed...

Страница 19: ...ith back lighting Charging status Battery Voltage Warning and Fault Code A01 E01 09 AC Input and DC Output Connection AC Input Connection Hardwire or AC with EU UK AZ plug DC Output Connection POS Hea...

Страница 20: ...ive if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to the manufacturer...

Страница 21: ...Page 21...

Страница 22: ...Page 22...

Страница 23: ...Page 23...

Страница 24: ...Page 24...

Страница 25: ...Page 25...

Страница 26: ...Page 26 Appendix B...

Отзывы: