Page
16
Procedure to Equalize Flooded Battery:
DANGER:
Explosion Hazard. The battery generates explosive gasses during equalization. Follow all
the battery safety precautions listed in the manual. When using the equalization mode, the user has
to be sure the battery connected to the channel is a flooded battery type. Equalizing a non-flooded
battery may overcharge battery and cause the battery to explode.
CAUTION:
Risk of Battery and Equipment damage. Only a Flooded lead-acid battery can be
equalized. Consult your battery manufacturer or read the battery manual when you try to equalize
your batteries.
Disconnect any DC load connected to the battery, as during equalize mode, the charger will produce
15.5V on 12V model, or 31.0V on 24V model to the batteries. The equalized voltage may damage the
DC connected to the battery. You must monitor the battery specific gravity throughout the equalization
process to determine the end of the equalizing cycle.
Before setting the equalization mode on the specific channel, please be sure the battery connected
to the specific channel is a flooded battery type. When the battery equalization process started, the
charger will automatically fully charge the selected channel first and follows with 1 hour of 15.5V
equalization process. Consult or follow the instruction as provided by the battery manufacturer on how
to check the battery electrolyte level and or refill with distilled or deionized water during the
1 hour’s
equalization period. All cells should have similar electrolyte levels. If distilled or deionized water is
added, batteries must undergo a complete charge cycle.
The charger cannot determine when to terminate the equalization of the battery. A one-hour timeout
is set as a safety feature by requiring the user to continually re-activate it as necessary after checking
the batteries manually. During the equalization mode, the other two battery banks are disabled.
Procedure to Awaken Over Discharge Lithium Battery
Some Lithium ion batteries have BMS circuitry that turns the battery off when over discharged. The
charger may not recognize a battery is connected and start the charging process. To awaken the
Lithium battery, press and hold ‘
INFO
’ and ‘
SET
’ buttons for 5 seconds. The charger will provide
13V (with 10A current limit) to the battery terminal for 10 seconds. If battery voltage was measured
at the terminal after 10 seconds, the lithium battery is awakened, and the charger will restart the
charging process. If no voltage was measured at the terminal, the charging process will terminate.
This function works only on Lithium battery setting.