SUPPLEMENTAL INSTRUCTIONS FOR THE KA-RC-1 

 

 

OTHER POINTS: 

ULTRASONIC RECORD RESTORATION SYSTEM v3.0 

CON’T 

-Never  run  the  machine  for  more  than  35  minutes.  After  35  minutes  of  continuous  use,    remove  the 
record assembly exposing the water in the tank, then turn the machine off for 10-15 minutes to allow the 
ceramic  ultrasonic  transducers  in  the  unit  to  cool.  Failure  to-do  so  will  damage  the  unit  and  void 
warranty.  ADDED:  NEVER RUN THE MACHINE WITH AN EMPTY TANK! 

-The temperature status bar on the unit moves from left to right as the unit is 
used, this as the ultrasonic bubbles that cavitate generate heat which in turns 
warms the water in the tub. Green,  (cold water), then Green

—Orange, then 

Green-Orange- Red (long bar), then Green-Orange-Red (long bar), Red (short 
bar). This is normal. 

 

 

-When you see a SMALLER RED LIGHT BAR to the right of the long red bar 
both APPEAR AND  FLASH,  the  ceramic transducer temperature has 
reached a preset limit. Complete your cycle with your record.  Remove the 
record assembly to expose the water in the basin and then turn the unit off 
and let cool for 10-15 minutes. Removing the record assembly cover allows 
the water in the tank to also cool more quickly. 

 

SOME HANDY TIPS: 

-NEVER LEAVE A RECORD IN THE UNIT WHEN THE RECORD IS NOT SPINNING. 

-CHANGE THE WATER OUT AFTER WASHING 15-20 RECORDS OR WHEN THE WATER IN THE 
TANK BECOME MURKY, WHICH EVER COMES FIRST. USE THE Degas/PULSE FUNCTION  FOR 
ONE CYCLE AFTER EVERY 5 RECORDS TO REMOVE AIR FROM THE WATER IN THE TANK. (This 
improves the cavitation effect of the ultrasonic) 

-NEVER LEAVE WATER IN THE TANK IF THE SYSTEM IS NOT IN USE OR KEEP OVERNIGHT. 
DISCARD USED WATER. DO NOT REUSE THE WATER AFTER A SESSION  THE NEXT DAY. 

-AFTER DAILY USE:

  1) EMPTY TANK, DISCARD WATER. 2) USE THE RABBIT CLOTH WITH A LITTLE 

70% ALCOHOL APPLIED TO POLISH THE STAINLESS STEEL TANK. 3) MIST THE UNDERSIDE OF 
THE RECORD ASSEMBLY WITH DISTILLED WATER. USE THE MICROFIBER RABBIT CLOTH TO DRY 
THE GEARS. MOVE THE BELT BY HAND TO GAIN ACCESS TO ALL GEARS, DRYING THEM. 4) 
REMOVE THE FELT RECORD GUIDES, MIST THEM WITH DISTILLED WATER, USE THE RABBIT 
CLOTH TO FIRST PAD DRY, THEN LET AIR DRY.  THEN RETURN THE PADS TO THEIR ORIGINAL 
POSITION.  

-BETWEEN  APPLICATIONS  OF  SURFACTANT,  MIST  THE  GOAT  HAIR  BRUSH  WITH  DISTILLED 
WATER. DRY THE BRUSH USING THE RABBIT CLOTH.  

THE 

SOUND CHOICE 

FOR YOUR RECORDS!     WWW.KIRMUSSAUDIO.COM       TEL: 303 263-6353 

EMAIL: [email protected] 

© KIRMUSS & ASSOCIATES,LLC 