Kirby Morgan KMB 18 Скачать руководство пользователя страница 4

Kirby Morgan, SuperLite, Band Mask, KMB Band Mask,  EXO, SuperMask, SuperFlow, and Rex  are all registered trademarks of 

Kirby Morgan Dive Systems, Inc.  Use of these terms to describe products that are not manufactured by KMDSI is not permitted without 
written permission from KMDSI. 
       © Copyright 1970-2017 Kirby Morgan Dive Systems, Inc.  All rights reserved.  KMDSI manuals, checklists and technical and training 
information is made available for the express use of owner/user of this Kirby Morgan products.  No part of this material may be reproduced, 
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or 
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc 

Copyright 2003-2017, Dive Lab®., Inc. All rights reserved.  TechTrnG 03101 

 
 

STEP 

PROCEDURES 

INITIALS 

3.  EGS Inspection 

Diver/Tender: Check the following (a-e):

 

 

a.

  Visually inspect all EGS hoses for signs of 

damage.

 

 

b.

  Check to ensure the cylinder is within the VIP 

and the hydro dates.

 

 

c.

  Ensure the First Stage Regulator pressure 

setting and the Over Pressure Bleed/Relief 
Valve settings have been checked within the 
past month. (Maintenance Log).

 

 

d.

  Inspect the Safety Harness and Cylinder 

Retainer for wear and damage.  
Repair/replace as necessary.

 

 

e.

  Document inspection/maintenance in 

Maintenance Log (Appendix 3). 

 

4.  Check the Mask   Diver/Tender: Check the following (a-d):

 

 

a.

  Rotate the Regulator Adjustment Knob in 

fully (clockwise), then rotate out 
(counterclockwise) 3 – 4 rotations to check 
for smooth operation.

 

 

b.

  Open the EGS Supply Valve on the cylinder.  

Log the pressure _______ psig.  Then open 
the Emergency Supply Valve on the Side 
Block.

 

 

c.

  Momentarily open the Mask Defogger/Steady 

Flow Valve ¾ to 1 full turn.  Check for a 
strong flow of gas out of the Defogging Train, 
and then close.  

 

 

d.

  Check for gas escaping from the One Way 

Valve.

 

 

5.  Attach the 

Umbilical

 

Tender: 

Blow down the Umbilical and attach it to the 
Umbilical Adapter on the One Way Valve. 

 

 

Diver/Tender:  Check the following (a-d):

 

 