Kirby Morgan KMB 18 Скачать руководство пользователя страница 2

Kirby Morgan, SuperLite, Band Mask, KMB Band Mask,  EXO, SuperMask, SuperFlow, and Rex  are all registered trademarks of 

Kirby Morgan Dive Systems, Inc.  Use of these terms to describe products that are not manufactured by KMDSI is not permitted without 
written permission from KMDSI. 
       © Copyright 1970-2017 Kirby Morgan Dive Systems, Inc.  All rights reserved.  KMDSI manuals, checklists and technical and training 
information is made available for the express use of owner/user of this Kirby Morgan products.  No part of this material may be reproduced, 
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or 
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc 

Copyright 2003-2017, Dive Lab®., Inc. All rights reserved.  TechTrnG 03101 

 
 

STEP 

PROCEDURES 

INITIALS 

1.

  

Hood and Band 

Assembly 

NOTE:

  When the 

screws that 
hold the 
Bands in 
position are 
properly 
torque, the 
Hood and 
Face Seal 
cannot be 
removed 
from frame. 

 

Diver/Tender:  Check the following (a-d): 

 

a

.  Visually inspect the Hood and Face Seal for 

signs of damage.  Check the Hood for tears, 
holes, and/or cuts.  Ensure the Face Seal is 
properly glued to the Hood. 

 

b

.  Check the screws that hold the Bands in 

position.  They must be properly torque to 

26 

inch pounds (28 kg cm)

.*  Guidance Modular 

O & M Manual.  

 

NOTE:

 Maximum torque, bands should have no 

less than an 1/8 inch (3mm) even gap 
between the bands. On installation , a marine 
grade anti-seize may be used on this screw. 
The screws may need adjustment after several 
dives.

 

 

c

.  Inspect the Bands.  Ensure the welds exhibit 

no signs of cracking and/or parting. Inspect 
all band keeper components 

DANGER:

 If the Bands become loose, the Hood  

      

and Face Seal could separate from the Mask.  

      This would cause the Mask to flood, which  
      could cause drowning.

 

 

d

. Inspect the Head Harness/Spider to ensure 

   

 there are no tears and/or cracks in the material.  

    Ensure all five legs are present.  If it is worn 
    and/or cracked, it must be replaced.

 

 

 

e. 

Ensure band keepers are installed and properly 

   

 torqued, Guidance Modular O & M Manual.

 

 

2.  Visually Inspect 

Mask 

 
NOTE:

 KMDSI 

recommends 
replacement 
of the Hose 
Assembly 
(117a) on the 

Diver/Tender:  Check the following (a-g): 

 

a

.  Visually inspect the interior/exterior of the 

Band Mask for any obvious signs of damage.  
Check to make sure the Oral Nasal Valve is 
correctly installed and the Oral Nasal Mask is 
installed on the Regulator Mount Nut 
properly.  Ensure the Nose Clearing Device 
operates smoothly.  Lubricate as necessary.  