Kirby Morgan KMB 18 Скачать руководство пользователя страница 1

Kirby Morgan, SuperLite, Band Mask, KMB Band Mask,  EXO, SuperMask, SuperFlow, and Rex  are all registered trademarks of 

Kirby Morgan Dive Systems, Inc.  Use of these terms to describe products that are not manufactured by KMDSI is not permitted without 
written permission from KMDSI. 
       © Copyright 1970-2017 Kirby Morgan Dive Systems, Inc.  All rights reserved.  KMDSI manuals, checklists and technical and training 
information is made available for the express use of owner/user of this Kirby Morgan products.  No part of this material may be reproduced, 
stored in any retrieval system, or transmitted, or used in any form or by any means, whether graphic, electronic, mechanical, photocopy, or 
otherwise by technology known or unknown, without the prior written permission of Kirby Morgan Dive Systems, Inc 

Copyright 2003-2017, Dive Lab®., Inc. All rights reserved.  TechTrnG 03101 

 
 

KMB 18/28 (BAND MASK) 

DAILY MASK AND EMERGENCY GAS SYSTEM 

SET-UP AND FUNCTIONAL CHECKLISTS 

APPENDIX A2.3

 

07-20-17 

 

THIS DAILY SET-UP AND FUNCTIONAL CHECKLIST SHOULD BE COMPLETED PRIOR TO COMMENCEMENT OF DAILY 
DIVING OPERATIONS AND AT LEAST EVERY 24 HOURS IF IN CONTINUOUS USE. 

 

WARNING: 

               These are recommended minimum checks when using Kirby Morgan KMB 
               18/28 Band Masks.  Additional checks may be required as dictated by the  
               conditions and tasks being performed.  

Failure

 

to

 

perform

 

in-water

 

checks

  

               

may

 

result in serious

 

injury or death

 

NOTE:

  Mask(s) being used in extreme environments will require more frequent inspection. 

NOTE:  

During removal of components for inspection, O-rings and other consumable items may 
be reused, providing they are clean and a visual inspection does not reveal any damage 
or deterioration.

   

NOTE:  

Perform the Side Block/Demand Regulator inspection procedures with gas supplies not 
connected to the Side Block.  Attach the gas supply at Step 5 of the “Side 
Block/Demand Regulator” inspection procedure. 

NOTE:  

Steps 3(a) - 3(e) use the EGS for setting up and checking the Mask’s systems.  For a 

proper check of the Demand Regulator adjustment, the First Stage Regulator must have 
an intermediate supply pressure output between 135  – 150 psig (9.3 – 10.3 bar).  The 
First Stage Bleed/Relief Valve should be set between 180 - 200 psig (12.4 – 13.8 bar).  
Do not attach the Umbilical until Step 6. 

 

Date: 

Mask Serial #: 

Associated Equipment Serial #(s): 

Technician 

(print name)

 

 
 
 