KMB 18 & 28 MANUAL
page 76
© Copyright 1970-2003 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 010518001
Fig. 6.51 Removing the whisker from the regulator.
6.12.2 WHISKER REPLACEMENT (35)
1) Replace the regulator exhaust valve (62) by
feeding the tail of the new valve into the hole in
the center of the body and pulling it throught until
the stem seats. The excess tail may be trimmed
off.
2) Stretch the whisker (35) onto the exhaust
flange of the regulator. Note: This step is much
easier to do with the regulator removed from the
Band Mask frame (17). See Section 6.11.2.
3) Attach the screws (38), plate (37), and spacers
(36) on each side of the port retainer (28) and
tighten to the correct torque. (see page 89) Do not
overtighten.
Fig. 6.52 Inspecting the regulator exhaust.
Fig. 6.53 Make sure the whisker spacers are in position.
Fig. 6.54 Be sure to tighten the screws that hold the whisker
and port to the proper torque settings. The correct setting
is 12 inch pounds (13 kg cm). See Appendix 1 for a complete
listing of torque specifications.