![Kirby Morgan KMB-18 A/B Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/kirby-morgan/kmb-18-a-b/kmb-18-a-b_operation-and-maintenance-manual_1971899076.webp)
KMB 18 & 28 MANUAL
page 66
© Copyright 1970-2003 Kirby Morgan Dive Systems, Inc. All rights reserved. Document # 010518001
DANGER: If silicone sealant is
blocking the air flow into the Band Mask
it must be cleaned out. If it is not the diver
may not be able to properly defog the
Band Mask or clear a flooded Band Mask
quickly. In addition, if the demand regu-
lator is not delivering air properly, the
diver cannot use the free flow system as
a source of breathing gas.
6.6
DEFOGGER VALVE
(83 THROUGH 92)
6.6.1 Disassembly of the Defogger Valve
(83 through 92)
Tools Required:
3/8 inch Slotted Flat Blade Screwdriver
13/16 inch Open End Attachment on Torque
Wrench
Kirby Morgan
83
84
85
86
87
88
89
90
91
92
93
94a
95
96
97
98
99
94b
101
102
103
100
104
114
115b
115
113
112
111
110
105
106
109
107
108
116b
117b
118b
116a
117a
118a
119b
119a
Fig. 6.33 Components of the A & B sideblocks.
NOTE: A slotted screwdriver is made by grind-
ing a small v in the blade of a flathead
screwdriver. This allows the knob locknuts to
be loosened or tightened while allowing for the
threaded stem end.