![Kirby Morgan KMB-18 A/B Скачать руководство пользователя страница 85](http://html1.mh-extra.com/html/kirby-morgan/kmb-18-a-b/kmb-18-a-b_operation-and-maintenance-manual_1971899085.webp)
KMB 18 & 28 MANUAL
page 75
Document # 010518001 © Copyright 1970-2003 Kirby Morgan Dive Systems, Inc. All rights reserved.
whisker (35)
plate (37)
spacers (36)
screw (38)
The whisker is held in place by being stretched
over the exhaust flange.
2) The whisker (35) is also held on each side of the
Band Mask at the port retainer (28). Two screws
(38) and one plate (37) hold each side. Complete
removal of the whisker (35) is done by removing
these screws (38) and plates (37). Take care not
to lose the four spacers (36).
3) Before removing the exhaust valve (62), care-
fully inspect the area around the edges to assure
the rubber exhaust valve (62) is in contact with
the regulator body (39). The metal cross area of
the body (39) under the valve (62) could be
slightly bent out resulting in the rubber valve (62)
not sealing. If the exhaust valve (62) is high and
not sealing, lightly press in on the metal cross.
The exhaust valve (62) can remain in place during
this. Bend the metal in slightly until the valve (62)
seats.
4) The regulator exhaust valve (62) is removed by
pulling it out.
DANGER: Do not attempt to install
new thread inserts in the frame for the
port retainer screws! If the installation is
done improperly, the port retainer can
come loose and the Band Mask could
flood. This could lead to drowning. Re-
turn the Band Mask to KMDSI for inspec-
tion and repair of threaded inserts.
6.12
RUBBER WHISKER (35)
6.12.1 Whisker (35) Removal
Tools Required:
1/4 inch Flat Blade Attachment on Torque Screw-
driver
To replace the whisker (35), the regulator must be
removed first. See Section 6.14.2 on regulator
removal
1) The rubber whisker (35) is removed by stretch-
ing and pulling the rubber away from the back of
the regulator. A metal cup called the exhaust
flange surrounds the rubber exhaust valve (62).
Fig. 6.50 The whisker assembly.