© Kirami Oy, Finland
3 / 11
INSTRUCTIONS FOR USE: Kirami Premium Pearly
INSTALLATION
Making the foundation
It is important to place the tub on an even surface that can bear the whole weight of the tub
(approx. 2000kg). The foundation can be evened out e.g. with chips (picture below) or if you want a
more solid foundation, it can be cast of concrete or covered with slabs. Do not install any tracks
under the tab in an EPS-based tub, but the bottom of the tab shall be on an even surface which is
completely load-bearing. NB! A terrace shall have a thick boarding or a slab under the tub. Remove
all vegetation from under the tub so that they do not penetrate the tub structures as they grow.
It is also important to see that the tub will not be surrounded by lawn or grass for a long time,
because it will prevent the wood from breathing and it promotes rotting. The rubber base in an EPS-
based tub can be covered with earth, as long as the ends of the wooden side panels get to breath.
Since the hot tub wall height is over 85 cm high, you should get a means of ingress (e.g. steps) to
the outside. Or install the hot tub so that the ingress is easily possible e.g. via terrace.
Note possible maintenance operation when selecting the position for the tub. It must be possible to
move the tub wherever necessary, even if it is embedded in a terrace, for example. The guarantee
will not cover any indirect costs, such as removal or construction of terraces.
Water discharge
The water discharge is the pipe (2 ½” female thread) on the opposite
side of the stove. Where the supplied shut-off valve with a 38 mm
hose coupling is installed. Plan the location of your tub so that the
water discharge will not cause any problems. Guide the water to the
side with hoses – hoses with a 38 mm ID can be used.
1.
Use pipe tape in valve thread connection about 15 rounds
thickening towards the base of the thread.
2.
Install the valve in its place. Turn the valve MAX 10 times
clockwise. Stop turning the valve in correct position at once.
Since turning back might leave the tape sealing leaking. The
correct position is marked with upward arrow and word UP.
The thread of the valve is not meant to go all the way in.
3.
Assembly of the plug.
27/88
09.04.2020
Содержание Premium Pearly
Страница 74: ...Kirami Premium Pearly 6 74 88 09 04 2020...
Страница 75: ...Kirami Oy Finland 2 13 Kirami Premium Pearly 5 1 40 C 10 2 3 4 5 6 7 8 75 88 09 04 2020...
Страница 76: ...Kirami Oy Finland 3 13 Kirami Premium Pearly 2000 EPS EPS 85 2 c 38 76 88 09 04 2020...
Страница 77: ...Kirami Oy Finland 4 13 Kirami Premium Pearly 38 1 15 2 10 UP 3 4 5 6 7 77 88 09 04 2020...
Страница 79: ...Kirami Oy Finland 6 13 Kirami Premium Pearly SUB SIDE 10 5 79 88 09 04 2020...
Страница 80: ...Kirami Oy Finland 7 13 Kirami Premium Pearly 19 CUBE MACU 10 15 Burner 80 88 09 04 2020...
Страница 83: ...Kirami Oy Finland 10 13 Kirami Premium Pearly pH 7 0 7 6 pH 20 ph Kirami 5 Kirami 83 88 09 04 2020...
Страница 84: ...Kirami Oy Finland 11 13 Kirami Premium Pearly 2 37 C 37 C 84 88 09 04 2020...
Страница 85: ...Kirami Oy Finland 12 13 Kirami Premium Pearly 24 6 pH 4 6 107 cm 170 cm 50 cm 90 cm 1420 l 85 88 09 04 2020...
Страница 88: ...User manual Premium Pearly 88 88 09 04 2020...