© Kirami Oy, Finland
CF 23 – Cartridge filter system
P
AGE
4/11
INSTALLATION
General
The installation location has to be flat and able to support the product installation. Position the filter under
consideration of the piping connections, so that it is convenient for operating and servicing. Ensure that the
compliance label is facing front to allow easy identification in case of service needs.
The device shall be connected to grounded 230V / 50Hz outlet with RCD protection.
The device should be installed as close to the pool as possible according to national and local regulations and
if possible, to the same level or a bit lower than the pool floor.
Make sure that water can flow away from the installation place to prevent flooding. Water runs out from the
“WASTE” outlet on the multiport valve.
Do not over tighten fittings or adapters, and tightening by hand is
enough.
Ensure solvents are not excessively applied to fittings as this could run into
O-ring and create sealing problems.
Do not plug in / turn on the device when the pool is empty, or the
water flow has been blocked.
The filter not meant to be used during bath. Remove it from the
outlet for that time!
Protecting the system
Notice! The system must be installed so that it is protected against direct sunlight, freezing temperatures
and water overflow from the pool / hot tub. This can be done by e.g. building an insulated pump house for it.
The following things must be taken into consideration when designing such house.
•
The pumphouse must have good drainage to allow waterflow away.
•
During summertime the pumphouse must have good ventilation, so that the inner temperature does
not go over 40
℃
, since that than overheat damage the pump.
•
If you are using the product during wintertime and the temperature can go under 0
℃
, then the house
must be heated with e.g. frost guard heater.
Note that the antifreeze element in the pump housing
does not keep the bath water melted.
We do not recommend usage in wintertime.
•
The pumphouse must be designed for easy access for using and maintenance of the product.
If you will build such pumphouse, it is recommended to test run the system on the base of the house, before
finishing the walls and the roof.
Winterization
When the filter stored for winter it should be stored into a warm storage to avoid freezing damage. Before
that it is good to empty the system completely from water. Remove and clean the cartridge, let it dry and
then store it to the warm place. Do not tighten the locking ring (image 3) fully when you store the system.
28/72
06.02.2021
Содержание CH 23
Страница 11: ...Kirami Oy Finland Patruunasuodatin CF 23 K ytt ohjeet SIVU 9 11 Kuva 8 11 72 06 02 2021...
Страница 22: ...Kirami Oy Finland Patronfilter CF 23 Bruksanvisning SIDA 9 11 Bild 8 22 72 06 02 2021...
Страница 33: ...Kirami Oy Finland CF 23 Cartridge filter system PAGE 9 11 Image 8 Placing the cartridge 33 72 06 02 2021...
Страница 44: ...Kirami Oy Finnland Patronenfilter CF 23 Gebrauchsanleitung Seite 9 11 Abbildung 8 44 72 06 02 2021...
Страница 55: ...Kirami Oy Finlande Filtre cartouche CF 23 Notice d emploi PAGE 9 11 Image 8 55 72 06 02 2021...
Страница 66: ...Kirami Oy Finland Patroonfilter CF 23 Gebruiksaanwijzingen PAGINA 9 11 Afbeelding 8 66 72 06 02 2021...
Страница 69: ...69 72 06 02 2021...
Страница 70: ...70 72 06 02 2021...