© 2005-2014 KIRAMEK, INC., Aichi Japan
FACTORY KEYLESS UPGRADE SECURITY
1440B
Ver. 2.1, Feb. 2014
Страница 1: ...2005 2014 KIRAMEK INC Aichi Japan FACTORY KEYLESS UPGRADE SECURITY 1440B Ver 2 1 Feb 2014...
Страница 2: ...em The 1440 is a state of the art device that will pro vide you with years of trouble free ser vice if used properly Please familiarize yourself with the content of this Owner s Guide to get the most...
Страница 3: ...ns and features are subject to change without notice TABLE OF CONTENTS Limited Lifetime Warranty 1 Included Items 2 System Operation 3 Arming 3 Disarming 3 Trunk Release 4 System Features 5 Door Trigg...
Страница 4: ...y damage to your VISION 1440 system that results from normal wear and tear accidents improper use neglect faulty wiring incorrect LQVWDOODWLRQ PRGL FDWLRQ UHPRYDO RU GHIDFHPHQW RI WKH SURGXFW VHULDO n...
Страница 5: ...ontrol Module 1pc Mounting Bracket 1pc Primary Harness 1pc Secondary Harness 1pc Status LED 1pc Shock Sensor 1pc Sensor Harness 1pc Window Decals 2pc 2 Sided Tape 1pc Backup Siren 1pc 2 keys included...
Страница 6: ...s the typical way to arm the 1440 with the shock sensor enabled Ensure that all doors are closed and then press the LOCK button on the vehi cle s factory keyless remote After you press Lock vehicle KD...
Страница 7: ...quickly after disarming ZKLOH WKH KD DUGV DUH VWLOO DVKLQJ SIREN MAY GO OFF If a door is opened too quickly after disarming while the siren is still chirping NOTE There are some rare cases where the f...
Страница 8: ...arms trigger the siren when the igni tion goes on while armed offering no remote start or turbo timer compat ibility IIP solves this compatibility versus security problem IGNITION TRIGGER IG PROTECT M...
Страница 9: ...ORY 7KH DVKHV UDSLGO ZKLOH WKH VLUHQ LV JRLQJ RII KHQ WKH VLUHQ VWRSV VHFRQGV ODWHU WKH 6WDWXV ZLOO DVK DFFRUGLQJ to Table 1 below to show which vehicle sector triggered the siren This Trigger Memory...
Страница 10: ...HUV e g shock sensor 1st stage trigger 2 STAGE SENSOR TRIGGER 1st Stage Warning Chirps When the included shock sensor detects a light impact to the vehicle body the siren will chirp 5 times Note that...
Страница 11: ...XUH VHWWLQJ KDV EHHQ FKDQJHG WRJJOHG 7KH QXPEHU RI UHHQ DVKHV should match the feature number you have chosen To go back to the previous setting Arm the system and repeat this procedure at Step 1 NOTE...
Страница 12: ...et to Remote Start Compatibility Mode RSCM the system will bypass the Shock Sensor and Ignition triggers and IIP will become active as described on page 5 of this manual IIP Trigger Selection When Rem...
Страница 13: ...if the ignition goes on the siren will not go off and the shock sensor will be bypassed in accordance with normal Remote Start Compatibility Mode functional ity Error Chirp When set to ON default the...
Страница 14: ...ds of Disarming press and release the Program Switch The LED inside the Control Module will start to turn on and off very VORZO RX PXVW FRXQW WKH QXPEHU RI DVKHV 3 Turn on the Ignition before WKH DVKH...
Страница 15: ...oor If you fail to close the door per Step 3 above but the disarm code you entered was correct the siren will stop after 30 seconds and the system will disarm at that time Step 3 above simply quiets t...
Страница 16: ...door lock signal detector read signals more loosely for reasons of security THE SYSTEM DISARMS SOMETIMES AND NOT OTHERS Some vehicles exhibit more door lock signal drift than others The drift causes...
Страница 17: ...VING AND THEN OPEN A DOOR This problem occurs when IIP is enabled see page 8 and the 1440 s GRN wire is not properly connected to IG as shown on page 12 of the Installation Guide Keep in mind that if...
Страница 18: ...and then again to Unlock Do WKH KD DUGV DVK I VR WKH LV 127 FRPSDWLEOH ZLWK RXU YHKLFOH Do I need optional devices in order to install the 1440 For some cars yes The two most common VISION part numbe...
Страница 19: ...NOTES...
Страница 20: ...ichi Ken 475 0936 JAPAN TEL 81 569 20 5585 FAX 81 569 20 5586 EMAIL support kiramek com VISION products are engineered in Japan and manufactured in strict accordance with Japanese QC standards at an I...
Страница 21: ...2005 2012 KIRAMEK INC Aichi Japan Ver 1 8 Mar 12 FACTORY KEYLESS UPGRADE SECURITY 1440B...
Страница 22: ...N installer All product warran ties immediately become void if the 1440 is not installed by an authorized dealer If you acquired this product without profes sional installation DO NOT install it yours...
Страница 23: ...and features are subject to change without notice TABLE OF CONTENTS Precautions Safety 1 Installation Tips 2 Technical Specifications 3 Included Items 4 Control Module Overview 5 System Wiring Diagram...
Страница 24: ...battery 3 Do not proceed with installing this system in vehicles that do not have a 12 volt electrical system This system will not function in 24 volt trucks and any damage resulting from such instal...
Страница 25: ...not manually turn off all the lights then remove the appropriate fuses and don t forget to replace the fuses after your installation is complete Remember to not lock the keys in the car during your in...
Страница 26: ...max during full siren blast 40 C to 125 C 125dB measured 30cm 1ft from speaker 1 tone 6 tone selectable by cutting wire on siren Water resistant cannot be submerged Status LED Mount LED Light Color Li...
Страница 27: ...trol Module 1pc Mounting Bracket 1pc Primary Harness 1pc Secondary Harness 1pc Status LED 1pc Shock Sensor 1pc Sensor Harness 1pc Window Decals 2pc 2 Sided Tape 1pc Backup Siren 1pc 2 keys included Gu...
Страница 28: ...ease Polarity Positive Polarity Negative Polarity 1440 Control Module CAUTION For most vehicles it is strongly advised that you do not change DIP switches 2 3 Lock Unlock Polarity The default setting...
Страница 29: ...r H3 H2 H1 WHT RED Hazard Light Input BLU YEL Door Unlock Input GRN Trunk Release Input GRN YEL Door Lock Input YEL YEL RED Pager Output GRN WHT Ignition Input ORG Siren Output GRN Light Flash Output...
Страница 30: ...ESS MODULE LOCK UNLOCK Harness LOCK UNLOCK 2 4 4URN 3IGNAL IGHTS 4 4URN 3IGNAL IGHTS TIP It doesn t matter if you connect to the LEFT or RIGHT sides WHT RED Vehicle Light Flash Relay Module LEFT RIGHT...
Страница 31: ...max for 15 sec onds while the siren goes off for triggering optional pag ing systems This wire can also be used to activate au tomotive illumination products such as strobe lights to enhance the intru...
Страница 32: ...es at times of Warning Chirps and Full Siren Blast See Fig 3 below H1 5 GRN wire Light Flash Output NOTE 1 NEVER use the GRN wire to control the Hazard lights the 1440 will not function properly Inter...
Страница 33: ...ig 4 The switches shown are open ciruit no ground when the door trunk is closed If using the optional DSS 6 refer to that manual instead of Fig 4 H1 7 WHT wire Door Trunk Input 7KLV ZLUH LV WKH PDLQ Y...
Страница 34: ...t all if your vehicle has a separate factory keyless module that connects to the door lock relay control module see page 7 In such a case you would connect the BLU YEL Unlock Input and GRN YEL Lock In...
Страница 35: ...OTE You only need to add the two diodes shown in Fig 6 for the sec ondary remote start turbo timer connection Also be sure to connect the GREEN wire only to the IGN wire or the Key in wire not both La...
Страница 36: ...sor Ground When the shock sensor detects hard impacts to the vehicle it sends a ground pulse on the WHITE RED wire When the 1440 control module sees the WHITE RED wire is grounded it triggers the full...
Страница 37: ...e gauge wire connections and cover with electrical tape or heat shrink tubing and or corrugate tube Mount the control module to D VHFXUH DW VXUIDFH RU XVH ZLUH WLHV WR DI WR D IDFWRU ZLUH KDUQHVV Cont...
Страница 38: ...an air duct to the inside of a trim panel But ALWAYS mount to plastic not to metal Mounting the sensor to the metal body of the car will cause sensitivity to become poor NEVER use screws or wire ties...
Страница 39: ...en triggers simply by Arming the system with the Sensor Bypass Arming which ignores the shock sensor see page 3 of the Owner s Guide Another consideration is temperature The sensitivity can vary by as...
Страница 40: ...2 Remove power from the Control Module pull out the H1 harness or remove the fuse for 5 seconds push release the Program Switch and then restore power 3 Push the Program Switch 3 times within 6 second...
Страница 41: ...to the previous setting Arm the system and repeat this procedure at Step 1 NOTES 1 There is no visual indication to let you know which setting RX KDYH FKRVHQ VLPSO WHVW WKH V VWHP WR FRQ UP RXU VHOHF...
Страница 42: ...nection as described on page 12 Failing to connect the GREEN wire properly can result in unexpected siren triggering or system arming If you used solder and if both the WHITE and GREEN wires are con n...
Страница 43: ...s OFF default kill power to the control module 3 Press and hold the Program Button for 3sec then release 4 Press and hold the Program Button again but don t release 5 Restore power while holding down...
Страница 44: ...ichi Ken 475 0936 JAPAN TEL 81 569 20 5585 FAX 81 569 20 5586 EMAIL support kiramek com VISION products are engineered in Japan and manufactured in strict accordance with Japanese QC standards at an I...