The purpose of the maintenance and adjustment schedule is to keep the
generator in the best operating condition.
NOTE: (1) Log hours of operation to determine proper maintenance.
(2) Service more frequently when used in dusty areas.
(3) These items should be serviced by an authorized dealer, unless the
owner has the proper tools and is machanically proficient. See the
Shop Manual.
7.MAINTENANCE
Maintenance Schedule
REGULAR SERVICE PE-
RIOD (1) Perform at every
indicated month or operating
hour interval, whichever oc-
curs first
EACH
USE
FIRST
MONTH
OR
20 HRS
EVERY 3
MONTHS
OR
50 HRS
EVERY 6
MONTHS
OR
100 HRS
EVERY
YEAR
OR
300 HRS
ITEM
Check
Change
Check
Clean
Clean-adjust
Clean
Clean
Check-adjust
Clean
Check
Spark plug
Spark arrester
Valve clearance
Fuel line
Engine oil
Air cleaner
Fuel sediment cup
Fuel tank and strainer
(2)
(3)
(3)
Every 2 years (Replace if necessary)(3)
CAUTION
WARNING
-15-
Shut off the engine before performing any maintenance. If the engine must
be run, make sure the area is well ventilated. The exhaust contains poison-
ous carbon monoxide gas.
Use genuine our parts or the equivalent. The use of replacement parts
which are not of equivalent quality may damage the generator.
2. Start the engine
The DC receptacle may be used while the AC power is in use.
An overloaded DC circuit will trip the DC circuit protector (push button comesout).
If this happens, wait a few minutes before pushing in the circuit protector to
resume operation.
5.4 Low oil alarm system
The low oil alarm system is designed to prevent engine damage caused by an
insufficient amount of oil in the crankcase. Before the oil level in the crankcase
falls below a safe limit, the low oil alarm system will automatically shut down the
engine (the engine switch will remain in the ON position).
If the low oil alarm system shuts down the engine, the low oil alarm indictor light
(red) will come on when you operate the starter, and the engine will not run. If this
occurs, add engine oil.
To stop the engine in an emergency, turn the engine switch OFF.
In normal use:
1. Switch off the connected equipment and pull the inserted plug.
2. Turn off the engine switch.
3. Turn the fuel valve lever to the OFF position.
occurs,
6.STOP-ING THE ENGINE
-14-