background image

PREFACE

Thank you for purchasing our generators.

This manual covers operation and maintenance of the IG2000, IG2000s, IG2000p 
generator.

All information in this publication is based on the latest product information 
available at the time of approval for printing.

We reserve the right to make changes at any time without notice and without 
incurring any obligation.

No part of this publication may be reproduced without written permission.

This manual should be considered a permanent part of the generator and should 
remain with it if it is resold.

Pay special attention to statements preceded by the following words;

Failure to properly follow these precautions can result in 
property damage, serious injury or DEATH! 
Read all labels and the owner's manual before operating 
this generator.
Operate only in well ventilated areas. Exhaust gas 
contains poisonous carbon monoxide, and can be deadly. 
Always stop engine before refueling. Wait 5 minutes 
before restarting.
Check for spilled fuel or leaks. Clean and/or repair before 
use.
Keep any sources of ignition away from fuel tank, at all 
times.

Indicates a strong possibility of severe personal injury or 
death if instructions are not followed.

Indicates a possibility of personal injury or equipment 
damage if instructions are not followed.

NOTE: Gives helpful information.

If a problem should arise, or if you have any questions about the generator, 
consult an authorized dealer.

The generators are designed to give safe and dependable 
service if operated according to instructions. Read and 
understand the Owner's Manual before operating the gen-
erator. Failure to do so could result in personal injury or 
equipment damage.

 The illustration may vary according to the type.

WARNING

CAUTION

WARNING

WARNING

Содержание IG2000P

Страница 1: ...S I N E M A S T E R DIGITAL INVERTER GENERATOR IG2000 IG2000s IG2000p WUXI KIPOR POWER CO LTD R R...

Страница 2: ......

Страница 3: ...this generator Operate only in well ventilated areas Exhaust gas contains poisonous carbon monoxide and can be deadly Always stop engine before refueling Wait 5 minutes before restarting Check for sp...

Страница 4: ...idity is 80 the rated power of generator is P P C 0 02 5 0 82 0 02 4KW N Modified coefficient table of ambient condition power Ambient temperature Altitude m 0 500 1000 2000 3000 4000 25 1 0 93 0 87 0...

Страница 5: ...rew screw M5 65 and screw M5 16 in turn Before energizing the light be sure to read the Generator Owner s Manual for best operation and maintenance information along with the safety precautions It is...

Страница 6: ...ment damage Place the generator at least 1m 3ft away from buildings or other equipment during operation Operate the generator on a level surface if the generator is tiled fuel spillage may result Know...

Страница 7: ...ese lables warn you potential hazards that can cause serious injury Read the labels and safety notes and precautions described in manual carefully If a label comes off or becomes hard to read contact...

Страница 8: ...W h Lube oil Single cylinder 4 stroke vertical air cooled OHV gasoline engine 105 6ml 58 40mm 8 5 1 2 2 4500 4500 T C I BOSCH R6 SUF Recoil starter Automotive unleaded gasoline 420 CD grade or SAE 10W...

Страница 9: ...the electrical appliance or equipment Take the electrical appli ance or equipment to an electrical shop for repair Stop and restart the engine Take the generator to an authorized dealer Turn the DC c...

Страница 10: ...gine switch on Turn the engine switch on Is the enough oil in the engine Add the recommended oil Is there a spark from the spark plug Replace the spark plug Take the generator to an authorized dealer...

Страница 11: ...ely e Reinstall the spark plug cap on the spark plug securely 3 Change the engine oil 4 Remove the spark plug and pour about a tablespoon of clean engine oil into the cylinder Crank the engine several...

Страница 12: ...must transport the generator on board If you must transport the generator on a rough road drain the fuel from the generator beforehand Before storing the unit for an extended period 1 Be sure the stor...

Страница 13: ...ill the recommended oil up to the top of the oil filler neck 1 Check the engine oil level WARNING Using nondetergent oil or 2 stroke engine oil could shorten the engine s service life Running the engi...

Страница 14: ...ventilated area with the engine stopped Do not smoke or allow flames or sparks in the area where the engine is refueled or where gasoline is stored Do not overfill the fuel tank there should be no fue...

Страница 15: ...decide to use a gasoline containing alcohol gasohol be sure it s octane rating is at least as high as that recommended by us There are two types of gasohol one containing ethanol and the other contain...

Страница 16: ...air cleaner Check the air cleaner element to be sure it is clean and in good condition Loosen the cover screw and remove the left side maintenance cover Press the latch tab on the top of the air clean...

Страница 17: ...the cover screw securely 6 Reinstall the maintenance cover and tighten the cover screw securely WARNING Do not use gasoline or low flash point solvents for cleaning They are flammable and explosive un...

Страница 18: ...hands with soap and water after handing used oil NOTE Please dispose of used motor oil in a manner that is compatible with the environment We suggest you take it in a sealed container to your local se...

Страница 19: ...u have the proper tools and are mechanically proficient Refer to shop manual for service procedures 3 For commercial use log hours of operation to determine proper maintenance intervals ITEM Perform a...

Страница 20: ...allel output cable only after stopping the generator If the parallel output cable is still connected cut off the current output after either generator was shut off Don t use the parallel output cable...

Страница 21: ...rators Shut off the generators 1 Turn off the power of electrical appliance pull out the receptacle plug 2 Turn off the two generators 3 First disconnect the cable on the PARALLEL OUTPUT terminals of...

Страница 22: ...rated power The total wattage of all appliances connected must be considered Do not exceed the current limit specified for any one receptacle Do not connect the generator to a household circuit This...

Страница 23: ...ights the overload indicator light red may damage the generator Marginal overloading that temporarily lights the overload indicator light red may shorten the service life of the generator Be sure that...

Страница 24: ...light red will go ON and current to the connected appliance will be shut off Stop the engine if the overload indicator light red comes ON and investigate the overload source Before connecting an appl...

Страница 25: ...ar the battery connect charging cable first to the generator then to the battery Disconnect cable first at the battery Before connecting charging cables to a battery that is installed in a vehicle dis...

Страница 26: ...lames and cigarettes away Provide adequate ventilation when charging The battery contains sulfuric acid electrolyte Contact with skin or eyes may cause severe burns Wear protective clothing and a face...