Chapter 1 Before Use
1-2
1. 1
Installation Requirements
The following conditions have to be satisfied when installing the KIP2300 Scanner.
1. Satisfy the following input power condition.
Voltage
100 - 240V +6%/-10%
Current
6A or higher
Frequency
50 or 60Hz.
KIP2300 can be connected to the outlet simply so far as the voltage is within 100 - 240V.
(+6% and -10% are acceptable)
2. Connect the power plug to the grounded outlet.
3. To completely disconnect the equipment from the power source, please draw the power plug
from the outlet. The outlet must be easily accessible near the equipment.
4. The temperature must be within 10 through 32 degrees centigrade, and the humidity must be
within 20 through 80%.
5. Keep the equipment away from fire, dust and direct sunlight. If it is impossible to avoid the
direct sunlight, please pull the curtain to intercept the sunlight.
7. Keep enough space around the machine as follows.
(The following values are the least requirements. Please keep a wider space if possible.)
1600mm
600mm 600mm
1000mm
(2000mm is required if the
original is thicker than 1.2mm)
(Front side)
(Rear side)
KIP2300
Содержание KIP 2300
Страница 1: ...Version A 1 KIP 2300 User Manual ...
Страница 14: ...Chapter 1 Before Use 1 7 1 4 Name Function of Each Part 1 4 1 Front view B OA R D 1 2 3 4 5 6 6 5 8 7 11 10 9 ...
Страница 37: ...Chapter 2 Basic Operation 2 17 10 The original is ejected to the rear side and stacked on the Rear Steel Tray ...
Страница 55: ...Chapter 4 Maintenance 4 6 Feed Rollers ...
Страница 56: ...Chapter 4 Maintenance 4 7 Feed Rollers ...