background image

Operation Manual

 

Celeb  401 DMX LED

Part No. 3100085 Rev 01                                                                                       07-24-2015

®

 

Содержание Celeb 401 DMX LED

Страница 1: ...Operation Manual Celeb 401 DMX LED Part No 3100085 Rev 01 07 24 2015 ...

Страница 2: ...Mount Univ 230U CEL 401Y 120U Celeb 401 DMX Yoke Mount Univ 120U CEL 401Y 230U Celeb 401 DMX Yoke Mount Univ 230U CEL 401P 120U Celeb 401 DMX Pole Op Univ 120U CEL 401P 230U Celeb 401 DMX Pole Op Univ 230U LVR CE490 P Celeb 401 Louver HP 90 Included GFR CE4 Celeb 401 Gel Frame Included Celeb 401 Center Mount Celeb 401 Yoke Mount Celeb 401 Pole Op ...

Страница 3: ...Mount 1 Flight Case Weight 52 5 lb 24kg Dimensions 53 5 x 11 x 16 5 136 x 28 x 42cm KIT C401Y 120U Celeb 401 DMX Yoke Mount Kit Univ 120U KIT C401Y 230U Celeb 401 DMX Yoke Mount Kit Univ 230U Kit Contents 1 Celeb 401 DMX Yoke Mount 1 Jr Pin 1 Ship Case Weight 57 lb 26kg Dimensions 54 5 x 9 5 x 25 138 5 x 24 x 63 5cm 3 Celeb 401 Center Mount Kit Celeb 401 Yoke Mount Kit ...

Страница 4: ...M mode In DIM mode a green light will appear to the left of the button and Dim level is displayed D Display Provides Kelvin Dim level and software revision data E LOCK RESET In LOCK mode an amber light is displayed to the left of the button In RESET mode the indicator light is green To reset to factory presets hold the LOCK RESET button for 5 seconds F On Off On Green light displayed Off Amber lig...

Страница 5: ... is Pin 1 Ground Pin 2 18 28VDC Pin 3 not used AC Input The Celeb is powered AC and includes an IEC connection A locking power cord is included with the fixture To remove the plug move the red tab to release The ballast has a built in power supply with universal input from 100 240VAC Ambient Operating Temperature The Celeb is designed to operate at temperatures from 14 F to 104 F 10 C to 40 C ...

Страница 6: ...vin factory preset buttons Left to right they display 2700K 3200K 4500K 5500K and 6500K A green indicator will light to the left of the active button Rotating the adjustment knob will change the Kelvin Press the rotating knob once to shift the Kelvin profile from Coarse to Fine increments In the Coarse mode the fixture can be adjusted in one rotation of the knob In Fine mode it will require 8 rota...

Страница 7: ...power is turned off or removed the fixture will remember its last setting Press the KELVIN DIM button The indicator light to the left of the button will turn green Rotating the adjustment knob will dim the light of the fixture Press the rotating knob once to shift the Dim profile from Coarse to Fine increments In the Coarse mode the fixture can be adjusted in one rotation of the knob In Fine mode ...

Страница 8: ...button again The indicator light will turn green In LOCK mode you can toggle back and forth on the KELVIN DIM button and review your Kelvin and Dim settings Note When the power is removed the fixture will reset to unlock To reset factory settings press and hold the LOCK RESET button for 5 seconds The indicator light will turn green and settings will reset to factory settings Lock Mode Reset Factor...

Страница 9: ...and hold the DMX ADDRESS button to select a DMX address The displayed number will flash while in edit mode Turn the dimming knob to select a valid address from 1 512 Note 0 or 513 999 are invalid addresses Press the rotating knob once to shift between Fine single digits and Coarse in 10th s address selection DMX Operation 9 To save the DMX channel press the DMX ADDRESS button again When set the di...

Страница 10: ...ll default to 6500K and dim setting will be at 100 Sliding the fader on the 1st channel will lower the light level Sliding the fader on the 2nd channel will lower the Kelvin from 6500K to 2700K See chart on the following page for approximate Kelvin dimmer levels The fixture may respond 4 slider channels depending on the dimmer board All manual controls are disabled once the DMX cable is applied an...

Страница 11: ...ecting Pin four and five as the pass thru allows secondary data to be passed through other equipment Do not use Microphone Cables and other general purpose two core cables designed for audio or signaling use They are not suitable for DMX512 Problems due to incorrect cabling may not be immediately apparent Microphone Cables may appear to work fine but systems built with such cables may fail or be p...

Страница 12: ...unlink all powered fixtures linked to the transmitter Note When power is removed from fixture it will remember its linked unlinked state Press the link unlink button on the transmitter to link to the Celeb 401 A fast red blinking light is displayed while searching for signal A slow green blinking light displays when linked A solid green light is displayed when linked and DMX data is present with a...

Страница 13: ...ure provide attachment points for a safety chain MTP LM Mounted on a junior stand Mounted to pipe grid A 180 turn loosens the orientation of the mount A right turn tightens the mount The tension on the lock lever may be adjusted by pulling the handle away from the mount This disengages the handle from the screw mechanism and allows the lever to be reoriented You can also use a screwdriver to adjus...

Страница 14: ...e also provides an attachment point for a safety chain Warning Use only M5 X 10mm screws supplied to assemble yoke Note that threads on the fixture are self locking and may seem tight Replacement screws Part No 2020127 Recommended torque setting USA 18 lb in Metric 2 Nm Pole Op The Celeb 401 Pole Op fixture includes a yoke with an attached junior pin It can be hung from a grid with a Junior pipe h...

Страница 15: ...re not necessary when taping the gel Operating Pole Op Mount Option Rope Hang The Blue cup alters the Pan left or right The White cup alters the Tilt up or down Accessory holders are also designed to enable 4 point rope hangs for specialty rigging applications Warning Do not pull yoke to adjust tilt Turn the white knob counter clockwise to angle the yoke 90 ParaBeam shown for illustration purposes...

Страница 16: ...e Do not press down along the top center portion of the Gel Frame or Louver Doing so may deform the Gel Frame or Louver over repeated usage Inserting Barndoors Position the barndoors alongside the extruded edge of the fixture Align the thumbscrews with the adjustable receptacle holes in the fixture and insert into place Lock the barndoors by turning the silver thumbscrew To remove reverse the proc...

Страница 17: ... OPP Open Protection Open circuit No open Repair Service Center SCP Short Circuit Protection Short circuit No short Repair Service Center Troubleshooting continued Can t set the DMX address You must Press and Hold the DMX Address button for 3 seconds in order to select an address The display will flash while in edit mode Select a valid address from 1 512 Note 0 or 513 and higher are invalid addres...

Страница 18: ...M Kino 81 Lollipop w Junior Pin 28mm KAS CE4 S Celeb 401 Center Ship Case KAS CE4 Y Celeb 401 Yoke Ship Case MTP I80 Junior Pin Assembly for Yoke 28mm 7010045 Celeb 401 Yoke Assembly 7010046 Celeb 401 Pole Op Assembly KAS CE4 Celeb 401 Center Flight Case KAS CE4 C Celeb 401 Center Travel Case ...

Страница 19: ... 198W Amperage VDC 8 25A at 24VDC Kelvin Range 2700K 6500K Dimming Range 100 1 Weight 26 lb 12kg Dimensions 50 x 16 5 x 5 127 x 42 x 13cm CEL 401C 120U Celeb 401 DMX Center Mount Univ 120U AC Input Voltage 100 240VAC 50 60Hz 210W Amperage VAC 1 8A at 120VAC DC Input Voltage 18 28VDC 198W Amperage VDC 8 25A at 24VDC Kelvin Range 2700K 6500K Dimming Range 100 1 Weight 26 lb 12kg Dimensions 45 x 14 x...

Страница 20: ...Dimming Range 100 1 Weight 26 lb 12kg Dimensions 50 5 x 16 5 x 5 128 5 x 42 x 13cm CEL 401P 230U Celeb 401 DMX Pole Op Univ 230U AC Input Voltage 240 100VAC 50 60Hz 207W Amperage VAC 1 0A at 230VAC DC Input Voltage 18 28VDC 198W Amperage VDC 8 25A at 24VDC Kelvin Range 2700K 6500K Dimming Range 100 1 Weight 26 lb 12kg Dimensions 50 5 x 16 5 x 5 128 5 x 42 x 13cm FCC Part 15 Verification This devic...

Отзывы: