1. Specification
1.1. Dimensions
4
· Width:
300 mm
· Height:
180 mm
· Depth:
100 mm
·
Supply voltage: 110-240 V AC or 12-24 V DC
·
Max input power: 24 VA
Note: The information supplied in this manual is for guidance only – no part of this may be used for
any agreement, whether express or implied, or to form any contract.
TMS300 CS Multi-Tank – User Manual
·
Optional wireless module
- 433 MHz
- Compatible with Watchman
®
Sonic
transmitter family
·
6 channels, 4-20 mA with internal 12 V DC
power supply
- Compatible with any 4-20 mA sensor i.e.
relative pressure, ultrasonic etc.
·
4-20 mA output (only with RF module)
Note: The alarm relays are 2 contact arrangements which are isolated (volt-free). These relays may be
used to trigger an external bell, warning lamp or digital communicator (telephone dialler).
1.5. Relay outputs
1.4. Outputs
1.3. Inputs
·
Operating temperature: 0˚C - 40˚C
·
Relay’s max switching current: 5 A
1.2. Electrical and environmental specification