background image

2. Safety precautions

6

Installation

Note:  This installation procedure is for guidance only, and its suitability should be verified by the installer.

The following safety precautions are strongly recommended:

·   

Before attempting to install and operate the unit, read the instruction and installation manual 
carefully.

·   

Installation and any maintenance should only be carried out by suitably qualified personnel.

·   

It is recommended that the unit be connected to the mains supply via a suitably rated isolating switch.

 Warning! When the unit is connected to the mains supply and the cover is open, the circuits at 
mains voltage will be exposed. Therefore when installing the unit, ensure all required connections 
(including battery connected, if included), are made and covers replaced before turning on the 
mains supply. Ensure that all the connections made are secure. If any maintenance work e.g. 
installing a new battery, is required ensure that the unit is isolated from the mains supply before 
removing the cover. Never leave the unit unattended if the cover has been removed and the mains 
supply is connected.

·   

Do not exceed unit ratings as shown on the ratings label.

·   

It is advisable to route mains cables away from low voltage or sensor cables.

Note: For viewing comfort, the unit should be positioned at eye level. The ideal operating temperature 
of the unit is (0

o

C to +40

o

C). It is always good practice to keep electronic equipment away from cold, 

heat and electrical plant, as extremes of temperature may reduce the lifetime of the device, and 
heavy electrical loads, switches, relays or contactors too close to the device may cause electrical 
and electro-magnetic interference when switched on or off.

TMS300 CS Multi-Tank – User Manual

Содержание TMS300 MULTI-TANK CS

Страница 1: ...kingspanenergymanagement com Smart Monitoring TMS300 CS Multi Tank User and Installation Manual ENG...

Страница 2: ...contrast 4 4 LCD backlight ON OFF 4 5 Buzzer ON OFF 4 6 Webserver password 4 7 Default setting 4 8 4 20 mA output 5 Web server connection 5 1 Network connection 5 2 Direct connection 5 3 Wi Fi connect...

Страница 3: ...Connectivity options via Local Network GSM 2G 3G or Internet Volt free relay outputs for overfll leak low level alarms sudden drop CE certificated Historical levels Levels litres percentage mm Alarms...

Страница 4: ...433 MHz Compatible with Watchman Sonic transmitter family 6 channels 4 20 mA with internal 12 V DC power supply Compatible with any 4 20 mA sensor i e relative pressure ultrasonic etc 4 20 mA output o...

Страница 5: ...ver direct connection via ethernet cable local network Internet port forwarding required Wi Fi network USB Wi Fi adaptor required 1 6 Connectivity 1 7 Sensor Any 4 20 mA sensor Watchman Sonic 003963 W...

Страница 6: ...replaced before turning on the mains supply Ensure that all the connections made are secure If any maintenance work e g installing a new battery is required ensure that the unit is isolated from the...

Страница 7: ...front lid Operating temperature 0 C 40 C Relay s max switching current 5 A Wall mount Drill four holes in the wall according to the template and insert the wall plugs Remove the Front Lid by unscrewin...

Страница 8: ...3 Mounting 8 TMS300 CS Multi Tank User Manual Template page 20...

Страница 9: ...section should be read carefully Power ON OFF indicator Alarm Triggered Indicator Max Volume Alarm Hard Max Volume Alarm Soft blinking icon Min Volume Alarm Hard Min Volume Alarm Soft blinking icon LA...

Страница 10: ...etwork Administrator This screen allows user to adjust the LCD contrast Use to adjust and press the key to confirm Main menu This screen allows user to choose any options available To back to Main men...

Страница 11: ...ial number Use to choose the channel and press the key to confrm This screen allows user to switch ON OFF auto backlight option Use to choose the option and press the key to confirm Backlight will sta...

Страница 12: ...the unit s IP address default 192 168 0 2 please contact with your network administrator Internet port forwarding required 12 TMS300 CS Multi Tank User Manual Router Computer Laptop Internet Laptop C...

Страница 13: ...s of the units serial number This password can be changed see page 11 User only for viewing levels Username user Password last 4 digits of the units serial number This password cannot be changed The U...

Страница 14: ...Sonic Enter the Sonic Height Sonic Height distance between the base of sensor to bottom of the tank 4 20 mA utrasonic sensor Watchman Sonic only with RF module Enter the Sonic Height Sonic Height dis...

Страница 15: ...ank User Manual 6 1 Channel wizard This screen allows user to connect to remote server GSM Kingspan SIM CARD For SIM CARD activation please contact Customer Service Click on Send registration file to...

Страница 16: ...not allow to register on Connect Sensor INTERNET port forwarding required please contact with your Network Administrator 6 2 Connectivity wizard Clik TEST button Test results will be displayed in few...

Страница 17: ...allows user to view all the settings for each channel e g tank details relays etc This screen allows user to view all the data from the channels TMS300 CS Multi Tank User Manual 6 4 Setup summary 6 5...

Страница 18: ...s and release the button STEP 6 The unit should enumerate as a BOOTLOADER USB Mass Storage STEP 7 Open the BOOTLOADER folder and drag n drop the s19 file STEP 8 After copying file has been completed d...

Страница 19: ...the next page has dimensions of 296x169 mm It represents in 1 1 scale the area required to be cut out for panel mount The four studs at the corners are showing the exact position of the four panel mou...

Страница 20: ...21...

Страница 21: ...wa St 62 090 Rokietnica Poland Tel 48 61 814 44 00 Czech Republic E sensoreu kingspan com Tel 420 725 114 555 Finland E sensoreu kingspan com Tel 48 61 660 94 46 Norway E sensoreu kingspan com Tel 48...

Отзывы: