1011026 User Manual Issue 01 (26.10.2021) 

 

 

 

Beacon units - P.No. 1009254 (where applicable)  

 

The Beacons provides an external visual indication which is used to indicate Failure & Service Reminders and 
may be included in the Power and Pressure Failure Detection System (PPFDS). The beacon is provided with a 
5m cable which can be extended to 30m. As supplied, the unit is protected against rain to IP65 and is supplied 
ready to mount on a suitable surface. Complete wiring according to Figure 3 & Figure 4. 
This unit is designed to be simple to install and safe in operation.  Any modification may adversely affect its 
weather resistance in operation.  If in any doubt, please consult us for advice. This is a sealed unit and not 
serviceable.  

 

Installation of High-Level Alarm 

 HLA (where applicable)  

 

Fix the black plastic bracket to the side wall of the baffle (the exact position is on the drawing included with 
the HLA kit). Secure the float cable in the cable gland as shown on the drawing in the HLA kit. Pull the float 
cable through any installed ducting into the blower housing. Complete wiring according to Figure 3 & Figure 4. 

 

For Biotec, Bioficient or BioSafe Applications 

7.7.1.

 

Power & Pressure Failure Detection System 

 PPFDS (where applicable) 

  

The panel is designed to be used in conjunction with the Beacon unit to provide warning of either loss of 
power or air pressure failure. 
For panels mounted outside the blower housing, additional tubing can be purchased, contact your local sales 
team for details. The panel can be mounted up to 30m away from the blower with no effect on the 
performance of the pressure failure detection system.  
To prevent damage to the PPFDS hole is fitted with a nylon bolt and nut. If the PPFDS is to be used, replace the 
bolt with the air inlet bulkhead fitting supplied inside the control unit. A short length of 4mm silicone tubing 
and a cable tie is also supplied. Connect the tubing from the bulkhead fitting to the 

Top Port

 of the pressure 

switch, SW2, see Figure 5. Tie the cable tie on the pressure switch to prevent the tubing slipping off as it is not 
barbed. 

 

Figure 5 - Pressure switch tubing 

 

For Biodisc Applications 

 

Using a suitable M20 gland, feed the motor power supply cable through Gland Hole and terminate to 
connections according to Figure 3 & Figure 4. 

7.8.1.

 

Installation of Sludge Return Pump (where applicable) 

 

Using a suitable M20 gland, feed the integral discharge pump power cable through Gland Hole and terminate 
to connection according to Figure 3 & Figure 4. 

Содержание Klargester 1002510

Страница 1: ...Kingspan Klargester 1011026 Domestic Wastewater Control Panel USER MANUAL...

Страница 2: ...Installation of High Level Alarm HLA where applicable 6 Beacon units P No 1009254 where applicable 7 Installation of High Level Alarm HLA where applicable 7 For Biotec Bioficient or BioSafe Applicati...

Страница 3: ...of Practice Statutory Requirements and any specific instructions issued by the supplier of these details Earthing All equipment must be earth bonded in accordance with the latest IEE Wiring Regulation...

Страница 4: ...1011026 User Manual Issue 01 26 10 2021 4 7 Installation Figure 1 1002510 Lid Cover Figure 2 Enclosure Mounting Dimensions Figure 3 Control Panel Wiring 1...

Страница 5: ...1011026 User Manual Issue 01 26 10 2021 5 Figure 4 DTP Control Panel Wiring 2...

Страница 6: ...tape at a depth of 150mm For loads up to 0 75kW and runs of less than 100 metres 2 5mm 3 core SWA is adequate For loads up to 1 55kW and runs of less than 100 metres 4 0mm 3 core SWA should be used I...

Страница 7: ...Applications 7 7 1 Power Pressure Failure Detection System PPFDS where applicable The panel is designed to be used in conjunction with the Beacon unit to provide warning of either loss of power or ai...

Страница 8: ...te socket below the battery on the PCB marked J3 After finishing wiring replace the isolator cover and screw Turn the mains supply on at the source Turn on the panel using the isolation switch It shou...

Страница 9: ...vation time Alarms The conditions shown below cause an alarm message to appear on the display the beeper sounds the beacon flashes and the common alarm telemetry relay is de energised Some alarm condi...

Страница 10: ...factory defaults This menu is intended for use by installation Service engineers only The menu is entered by simultaneously pressing then releasing the three buttons On entry to the menu all outputs...

Страница 11: ...4 hour format The display will show Figure 13 Date Time Use and to move between date and time Pressing the button will freeze display of the clock and enter edit mode to allow the date or time to be s...

Страница 12: ...ickle Charge indicates that the unit is fully charged and maintaining the battery 8 6 7 Factory Defaults This option allows the control unit to be set back to the defaults as they were when the unit l...

Страница 13: ...lower J9 Chemical dosing pump Grundfos KP 350 Grundfos KP 250 Secoh JDK 250 Kingspan 404390 Fusing F1 De sludge pump terminals 3 4 T 5A H 250V F2 Internal power supply unit T 2A H 250V F3 Motor blower...

Страница 14: ...y 16 x 2 character LCD Green power LED Real Time Clock Event log timestamps and controlling the operation of the motors blowers according to a timetable LED Beacon 1009254 Only the LED beacon 1009254...

Страница 15: ...ay Motor Blower Start Time Time of Day where Unit is started 00 00 00 Stop Time Time of Day where Unit is stopped 23 59 59 Run Time Time for the components to Run 23 59 59 24 hours Pause Time Time for...

Страница 16: ...1011026 User Manual Issue 01 26 10 2021 16 This Page Intentionally Left Blank...

Отзывы: