Aeromax Plus Air Source Heat Pumps provide thermodynamic heating by 
means of a vapour compression cycle. In the same way that a fridge uses 
refrigerant to extract heat from the inside to keep the food cool, air source heat 
pump extracts heat from the outside air, and uses it to heat the home through 
radiators, underfloor system or provide domestic hot water. It can extract heat 
from the air even when the outside temperature is as low as -20°C. 

Although Aeromax Plus is powered by electricity, when it is installed and designed 
correctly can often result in the system costing less to run than systems heated 
by oil, LPG, electricity or coal. Your heating costs will depend on how you use 
your heating or hot water and the temperature of your radiators. Aeromax Plus is 
cost-effective to use all year round, but you can ensure it is at its most efficient by 
running your radiators or underfloor heating at lower temperatures.

1.   EVAPORATOR

The evaporator collects heat from 
the outside air, which is then drawn 
into the unit by the fan through the 
evaporator fins and expelled through 
the front grille. The evaporator has 
liquid refrigerant passing through 
it, which is at a considerably lower 
temperature than the outside air, 
therefore the air gives up its heat to 
the refrigerant, which then vaporises.

2.  EOMPRESSOR

This preheated vapour now travels to 
the compressor where it is compressed 
and upgraded to a much higher 
temperature.

3.  CONDENSER (heat exchanger)

The hot vapour now enters the 
condenser where it is surrounded by 
water from the heating system. The 
heat is given up to the cooler water 
and the now cooler refrigerant returns 
to its former liquid state but still under 
high pressure from the compressor.

4.  EXPANSION DEVICE

This high pressure is then released 
by passing the liquid through the 
expansion device and from there it 
returns to the evaporator and the cycle 
starts again.

Page 3

OUTSIDE AIR

Every air source heat pump  
has four main parts:
1.   Evaporator
2.  Eompressor
3.  Condenser (heat exchanger)
4.  Expansion device

HEAT PUMP

INTERNAL 

HEATING

2

1

4

3

HOW DOES  

IT WORK?

AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE

KINGSPAN HEAT PUMPS

Содержание AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE

Страница 1: ...AEROMAX PLUS AIR SOURCE HEAT PUMP PACKAGE HOMEOWNERS GUIDE...

Страница 2: ...c hot water It does this in the same way that a fridge extracts heat from its inside It can extract heat from the air even when the outside temperature is as low as 20 C The heat generated can be used...

Страница 3: ...fficient heating output to provide these services without any supplementary heating being required You ll find your Aeromax Plus unit close to a wall outside your property It can also be mounted off t...

Страница 4: ...he outside air which is then drawn into the unit by the fan through the evaporator fins and expelled through the front grille The evaporator has liquid refrigerant passing through it which is at a con...

Страница 5: ...ble room thermostat controls the temperature of the main living area while thermostatic radiator valves control the temperatures of the radiators in other rooms The Aeromax Plus radiator system works...

Страница 6: ...water timings given in the tables below allow for the immersion heater to beactivated after the hot water cycle in the morning This will sanitise the tank temperature to between 60 65 C Typical winter...

Страница 7: ...rmally takes place for about 4 minutes per hour When defrosting the fan will stop and water vapour may be seen rising from the heat exchanger This is normal and is not a cause for concern SAFETY PRECA...

Страница 8: ...In some cases your system may be fitted with an advanced controller or a comfort module with auxiliary heaters that also houses an advanced controller Normally the advanced controller or comfort modul...

Страница 9: ...te can take a long time but when it is warm it can supply heat for several hours and only needs topped up Therefore underfloor heating should not be turned off for long periods 3 THE FANS ARE RUNNING...

Страница 10: ...ther inverter board error The error code can be identified from the flashing LED on the Diagnostic Indicator using the following table In the case of more than one error the error with the highest pri...

Страница 11: ...T APPLY IF 1 The heat pump and associated equipment has been incorrectly sized for the application 2 The heat pump and associated equipment has not been installed and commissioned in complete accordan...

Страница 12: ...Wakefield West Yorkshire WF1 5QU T 0845 260 0258 F 0845 260 0259 sales kingspan renewables com www kingspanenviro co uk Portadown Office 180 Gilford Road Portadown Co Armagh BT63 5LF T 028 3836 4444...

Отзывы: