Installation Clearances – 39 / 42 / 47 ZVFCV
Carefully follow the instructions below. This will ensure safe installation.
IMPORTANT:
Vent-free gas log heaters add
moisture to the air. Although this is beneficial,
installing firebox in rooms without enough
ventilation air may cause mildew to form from
too much moisture. See
Air for Combustion
and Ventilation
section in this manual.
IMPORTANT:
Make sure the firebox is level. If firebox is not level, log set will not work properly.
Clearance To Combustibles
39ZVFCV
42ZVFCV
47ZVFCV
A
Front of Fireplace
36”
36”
36”
B
Back (From Stand-offs)
0”
0”
0”
C
Side (From Stand-offs)
0”
0”
0”
D
Floor*
0”
0”
0”
E
Bottom of Fireplace to Ceiling
83”
83”
83”
F
Top (From Stand-offs)
0”
0”
0”
G
Top of Fireplace to Minimum Enclosure
7”
7”
7”
*Note: If appliance is installed directly on carpeting or other combustible material other than wood flooring, a metal or
wood panel extending the full width and depth of the appliance must be used. Carpet may extend 1 inch above the floor
of the appliance.
⚠
WARNING
Never install the firebox:
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, clothing, or other flammable
objects are less than 36 inches from the front, top, or sides
of the firebox
• in high traffic areas
• in windy or drafty areas
NOTICE
A qualified service person
must install firebox. Follow all
local codes.
⚠
WARNING
Ensure the minimum
clearances are
maintained. Left and
right clearances are
determined when
facing the front of the
heater.
⚠
WARNING
Maintain the
minimum
clearances.
If you can, provide
greater clearances
from floor, ceiling,
and adjoining wall.
15