![Kingsman ZDV3318 Series Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/kingsman/zdv3318-series/zdv3318-series_installation-instructions-manual_1970892029.webp)
Gas Conversion –Part A ZDV3318
1. Remove [3]screws from false bottom.
Remove the false bottom and air
restrictor.
2. Remove [2]screws the from main burner.
Slide main burner to the left, and lift out
of fireplace.
3. Adjust the Air Shutter to the correct
Primary Air setting as specified in the
manual or on the label plate. To adjust
the Primary Air setting, loosen screw on
the side of the Air Shutter and rotate to
the correct opening using a drill bit or
tape measure. Retighten screw.
4. Remove the Main Orifice using a ½”
wrench and replace with the new
Conversion Orifice which came with the
Conversion Kit.
5. Replace the main burner. Install the new
Pilot Orifice (See
Pilot Conversion
) and
Hi/Lo valve regulator by following
instructions supplied with the Conversion
Kit.
6.
Replace air restrictor and false bottom
.
WARNING: This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer’s instruction s and all applicable codes and requirements of the authority having jurisdiction. If the
information in these instructions is not followed exactly a fire, explosion or production of carbon monoxide may result
causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper
installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked
as specified in the manufacturer’s instructions supplied with kit.
Caution:
The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding with the conversion
.
29
Содержание ZDV3318 Series
Страница 31: ...Gas Conversion for Modulator PART C WARNING WARNING 31 ...
Страница 35: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 35 ...
Страница 36: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 36 ...
Страница 43: ...Proflame 2 Remote Control 43 ...
Страница 45: ...45 ...