background image

4

SAFETY INFORMATION

WARNINGS

WARNINGS

Important:

Read this owner’s manual carefully and completely before trying to assemble, operate, or service this logset. Im-

proper use of this logset can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide
poisoning.

Early signs of carbon monoxide poisoning resemble the 
flu, with headaches, dizziness, and / or nausea. If you have
these signs, the heater may not be working properly. 

Get

fresh air at once! 

Turn off gas appliance. Have appliance

serviced. Some people (such as pregnant women, persons
with heart or lung disease, persons with anemia and those at
high altitudes) are more affected by carbon monoxide than
others. Make certain you read and understand all warnings.

1.

Use correct gas type for your appliance. Do not convert
from one gas type to another.

2.

If this appliance is for use with Propane gas, do not place propane supply tank(s) inside any structure. Locate propane
supply tank(s) outdoors.

3.

If you smell gas:
– Shut off gas supply.
– Do not try to light any appliance.
– Do not touch any electrical switch; do not use any phone in your building.
– Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
– If you cannot reach your gas supplier, call the fire department.

4.

Do not use the appliance for burning trash or cooking. Never place matches, paper, garbage, or any other material on top
of logs or logs into flame.

5.

Always operate appliance with front fireplace screens closed and glass doors open, unless other provisions for combus-
tion air are provided, the screen shall have opening (s) for induction of combustion air.

6.

A Damper Clamp must be installed to provide the minimum permanent vent opening to exhaust combustion by-products,
refer to charts in manual to determine opening.

7.

Make sure any safety screen or guard removed for servicing is in place before running appliance.

8.  Never run appliance in a small, closed room. Open the door into next room to help ventilate.

9.

If appliance shuts off, do not relight until you provide fresh outside air. If appliance keeps shutting off, have it serviced.

10.  Do not run appliance:

– where flammable liquids or vapors are used or stored.
– under dusty conditions.

11. Surface of appliance becomes very hot when operating. Keep children and adults away from hot surface. Appliance will

remain hot for some time after shutdown. Allow surface to cool before touching.

12. Do not use this appliance if any part has been submerged under water. Immediately call a qualified technician to inspect

the appliance and to replace any part of the control system and gas control which has been under water.

13. The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI

Z223.1.

14. Never install the appliance:

– in a bedroom, bathroom, mobile home, or recreational vehicle.
– where curtains, furniture, clothing, or other flammable objects are less than forty-two inches (42”) from the front 

of the appliance.

– in high traffic areas.
– in windy or drafty areas.

15. Disconnect the appliance and its individual shut off valve from the gas supply piping system during any pressure testing

of that system at test pressures in excess of 1/2 psig, (3.5KPa).

DANGER

CARBON MONOXIDE POISONING

MAY LEAD TO DEATH!

NOTE:

It is recommended that a Carbon Monoxide (CO)

Detector be installed in or near bedrooms and on all levels
of your home. Place a detector about 15 feet (4.5 meters)
outside the room that houses your gas appliance.

Содержание VB18

Страница 1: ...ed with this appliance may result in property damage or personal injury WARNING This appliance and its main gas valve must be disconnected from the gas supply piping system during any pressure testing...

Страница 2: ...s log set in it without rectifying the sooting issue will not solve this There are reasons why fireplaces soot the damper is not open far enough too small of flue too large of fireplace opening obstru...

Страница 3: ...46 000 73 000 1 6 3 5 20 Non 5 5 10 VGB24LP VSB24LP 24 30 Liquid Propane 68 000 86 000 6 3 10 37 25 11 13 Log Set required for each burner above VLOG18 Split Oak 18 VLOG24 Reversible Charred Split or...

Страница 4: ...r Clamp must be installed to provide the minimum permanent vent opening to exhaust combustion by products refer to charts in manual to determine opening 7 Make sure any safety screen or guard removed...

Страница 5: ...excessive lint from carpeting bedding material etc It is important that control compartment burner and circulating air passage of the appliance be kept open 20 When operated for the rst time there wi...

Страница 6: ...located on the floor or wall of fireplace If this is not done drafting may result causing pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper INSTALLING DAMPER STOP A...

Страница 7: ...ireplaces Warning Check the fireplace for proper venting use a match or smoke pen if any spillage is noted then the Damper shall be opened until no spillage occurs If a proper draft can not be obtaine...

Страница 8: ...ing gas line to regulator Secure all joints tightly with wrench but do not over tighten If a flexible gas line is used take care not to kink connector The burner pressure is controlled by the regulato...

Страница 9: ...the heater to prevent moisture and contaminants from passing through the pipe to the heater controls and burners Failure to do so could prevent the heater from operating reliably INSTALLING Gas Line...

Страница 10: ...NG only or 1 4 small rock LP only inside and in front of burner pan Place 1 large rock inside in front and around the sides of the pan Place rock wool in front of the grate bar Sprinkle vermiculite ov...

Страница 11: ...lica sand NG only or 1 4 small rock LP only inside and in front of burner pan Place 1 large rock inside in front and around the sides of the pan Place rock wool in front of center log support as shown...

Страница 12: ...k in side in front and around the sides of the pan Place rock wool in front of the grate bar Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on the back of the grate pull for...

Страница 13: ...1 large rock in side in front and around the sides of the pan Place rock wool in front of center log support as shown Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on the r...

Страница 14: ...and around the sides of the pan Place rock wool inside the middle of the pan and also in front of the grate bar Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on the back of...

Страница 15: ...arge rock in side in front and around the sides of the pan Place rock wool in front of center log support as shown Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on rear log...

Страница 16: ...in front and around the sides of the pan Place rock wool inside the middle of the pan and in front of the grate bar Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on back o...

Страница 17: ...Place 1 large rock in side in front and around the sides of the pan Place rock wool in front of center log support as shown Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 o...

Страница 18: ...E 12 Millivolt Models NOTE Thermostat not to be used on a vented gas log set Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal inj...

Страница 19: ...with brush attachment Vacuum loose particles and dust from burner ports valve and blower compartments Vacuum any accumulation of lint from primary mixing hole Propane Only Inspect pilot for operation...

Страница 20: ...18N VGB18N VSB24N VGB24N 13b 1001 P745SI TC Pilot Burner Assembled LP 199 745 VSB18LP VGB18LP VSB24LP VGB24LP 14a 24LGR P119DC N MP119 DC 3 8 x 1 2 Reducing Coupler VSB18N VGB18N VSB24N VGB24N 14b 24L...

Страница 21: ...iency re sulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoever including additional or unusual use of supplemental electric...