background image

Installation Instructions

Model Number VB18 and VB24 Vented Gas Log

Models VB18 and VB24 Listed Certified  for USA and Canada

Certified to: ANSI Z21.60–2003, ANSI Z21.60a–2003, ANSI Z21.60b–2004,

CSA 2.26–2004, CSA 2.26a-2003, CSA 2.26b-2004

WARNING:

Improper

installation, adjustment, alteration,
service, or maintenance can cause
injury or property damage. Refer to this
manual for correct installation and
operational procedures. For assistance
or additional information consult a
qualified installer, service agency, or the
gas supplier. 

Installation and the provisions for com-
bustion and ventilation air must con-
form with the National Gas and
Propane Installation Code, ANSI
Z223.1/NFPA 54 or the CSA B149.1,
Natural Gas and Propane Installation
Code.

WARNING: 

These gas logs

sets are for installation in a solid fuel
burning fireplace with a working flue
and constructed of noncombustible
material.

NOTE: Solid fuels shall not be burned
in the fireplace where the logset is in-
stalled.

This appliance must be installed by a licensed plumber or gas fitter in the Commonwealth of Massachusetts and
meet the requirements of 527 CMR 30 and 248 CMR.

NOTE: Installer, leave these

instructions with the 

Consumer!

WARNING:

Failure to position the parts in accordance with

these diagrams or failure to use only parts specifically approved
with this appliance may result in property damage or personal
injury.

WARNING: 

This appliance and its main gas valve must be

disconnected from the gas supply piping system during any pressure
testing of that system at test pressures equal to or less that 1/2 psi
(3.5kPa). The appliance must be isolated from the gas piping system by
closing its equipment shutoff valve during any pressure testing of the gas
supply piping system at test pressures equal to or less than 1/2 psi
(3.5kPa).

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Read this complete manual before beginning installation.

These instructions must be kept with the unit for future reference.

FOR YOUR SAFETY

WARNING: Improper installation, adjustment, alteration,

service or maintenance can cause property damage, personal
injury or loss of life. Refer to this manual. Installation and service
must be performed by a qualified installer, service agency or the
gas supplier.

Do not store or use gasoline or other flammable vapors and liquids
in the vicinity of this or any other appliance.

What to Do If You Smell Gas

Do not try to light any appliance.

Extinguish any open flame.

Do not touch any electrical switch.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbour’s phone.

If you can not reach your gas supplier, call the fire department.

Printed in Canada 

May 22 2015

  

18

VB-MAN

A Division of R-Co. Inc.

2340 Logan Avenue

Winnipeg, Manitoba, Canada  R2R 2V3

Ph: (204) 632-1962

Содержание VB18

Страница 1: ...ed with this appliance may result in property damage or personal injury WARNING This appliance and its main gas valve must be disconnected from the gas supply piping system during any pressure testing...

Страница 2: ...s log set in it without rectifying the sooting issue will not solve this There are reasons why fireplaces soot the damper is not open far enough too small of flue too large of fireplace opening obstru...

Страница 3: ...46 000 73 000 1 6 3 5 20 Non 5 5 10 VGB24LP VSB24LP 24 30 Liquid Propane 68 000 86 000 6 3 10 37 25 11 13 Log Set required for each burner above VLOG18 Split Oak 18 VLOG24 Reversible Charred Split or...

Страница 4: ...r Clamp must be installed to provide the minimum permanent vent opening to exhaust combustion by products refer to charts in manual to determine opening 7 Make sure any safety screen or guard removed...

Страница 5: ...excessive lint from carpeting bedding material etc It is important that control compartment burner and circulating air passage of the appliance be kept open 20 When operated for the rst time there wi...

Страница 6: ...located on the floor or wall of fireplace If this is not done drafting may result causing pilot outage or sooting Use a heat resistant sealant Do not seal chimney flue damper INSTALLING DAMPER STOP A...

Страница 7: ...ireplaces Warning Check the fireplace for proper venting use a match or smoke pen if any spillage is noted then the Damper shall be opened until no spillage occurs If a proper draft can not be obtaine...

Страница 8: ...ing gas line to regulator Secure all joints tightly with wrench but do not over tighten If a flexible gas line is used take care not to kink connector The burner pressure is controlled by the regulato...

Страница 9: ...the heater to prevent moisture and contaminants from passing through the pipe to the heater controls and burners Failure to do so could prevent the heater from operating reliably INSTALLING Gas Line...

Страница 10: ...NG only or 1 4 small rock LP only inside and in front of burner pan Place 1 large rock inside in front and around the sides of the pan Place rock wool in front of the grate bar Sprinkle vermiculite ov...

Страница 11: ...lica sand NG only or 1 4 small rock LP only inside and in front of burner pan Place 1 large rock inside in front and around the sides of the pan Place rock wool in front of center log support as shown...

Страница 12: ...k in side in front and around the sides of the pan Place rock wool in front of the grate bar Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on the back of the grate pull for...

Страница 13: ...1 large rock in side in front and around the sides of the pan Place rock wool in front of center log support as shown Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on the r...

Страница 14: ...and around the sides of the pan Place rock wool inside the middle of the pan and also in front of the grate bar Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on the back of...

Страница 15: ...arge rock in side in front and around the sides of the pan Place rock wool in front of center log support as shown Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on rear log...

Страница 16: ...in front and around the sides of the pan Place rock wool inside the middle of the pan and in front of the grate bar Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 on back o...

Страница 17: ...Place 1 large rock in side in front and around the sides of the pan Place rock wool in front of center log support as shown Sprinkle vermiculite over top of lava rock and rock wool Place rear log 1 o...

Страница 18: ...E 12 Millivolt Models NOTE Thermostat not to be used on a vented gas log set Warning If you do not follow these instructions exactly a fire or explosion may result causing property damage personal inj...

Страница 19: ...with brush attachment Vacuum loose particles and dust from burner ports valve and blower compartments Vacuum any accumulation of lint from primary mixing hole Propane Only Inspect pilot for operation...

Страница 20: ...18N VGB18N VSB24N VGB24N 13b 1001 P745SI TC Pilot Burner Assembled LP 199 745 VSB18LP VGB18LP VSB24LP VGB24LP 14a 24LGR P119DC N MP119 DC 3 8 x 1 2 Reducing Coupler VSB18N VGB18N VSB24N VGB24N 14b 24L...

Страница 21: ...iency re sulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoever including additional or unusual use of supplemental electric...

Отзывы: