background image

Gas Line Installation 

 

This gas appliance should be installed by a qualified installer in accordance with local building codes and with current 

CAN/CSA - B149.1 installation codes for Gas Burning appliances and equipment in Canada and the National Fuel Gas 

Code ANSI Z223 in the U.S.A. 

State of Massachusetts 

For the state of Massachusetts a T-handle gas shut-off valve must be used on a gas appliance. This T-handle gas shut-

off valve must be listed and approved by the state of Massachusetts. This is in reference to the state of Massachusetts 

state code CMR238. 

 

1.  The gas pipeline can be brought in through either the right or left side of 

the appliance. Knockouts are provided at these locations to allow for the 

gas pipe installation and testing of any gas connection. 

2.  The gas control inlet is 3/8” NPT. Typical installation layout for rigid pipe 

is shown at right. 

3.  When using copper or flex connector, use only approved fittings. Always 

provide a union so that gas line can be easily disconnected for burner or 

fan servicing. See gas specification for pressure details and ratings. 

4.  When a vertical section of gas pipe is required for the installation, a 

condensation trap is needed. See CAN/CSA-B149.1 for code details. 

5.  For natural gas, a minimum of 3/8” iron pipe with gas minimum pressure of 5.5” w.c. must be used for supply from the 

gas meter. Consult with the local gas utility if any questions arise concerning pipe sizes. 

6.  Ports are accessible for test gauge connection both on the inlet and outlet of the gas valve. 
7.  Turn the gas supply ON and check for leaks. DO NOT USE OPEN FLAME FOR THIS PURPOSE. Use an approved 

leak testing solution. 

8.  The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any 

pressure testing of that system at test pressures in excess of 1/2psig [3.5 kPa]. 

9.  The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any 

pressure testing of the gas supply piping system at test pressures equal to or less than 1/2psig [3.5 kPa]. 

Note: The gas line connection may be made of 1/2” rigid pipe, 1/2” copper pipe or an approved flex connector. Since 

some municipalities have additional local codes, it is always best to consult your local authorities and the current 

CAN/CSA - B149.1 installation code in Canada or the National Fuel Gas code ANSI Z223.1 in the U.S.A. 

IMPORTANT: Check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING. 

 

Models 

IDV34N/NE/NE2  IDV34LP/LPE/LPE2  IDV44N/NE/NE2  IDV44LP/LPE/LPE2 

Fuel 

Natural Gas 

Propane 

Natural Gas 

Propane 

Gas Control 

Millivolt Adjustable 

Maximum Input 

[BTU] 

31,000 HI  

20,900 LO 

28,500 HI  23,100 

LO 

34,250 HI  

24,860 LO 

30,030 HI  

22,840 LO 

Orifice Size (0-4500ft) 

#35 

#51 

#32 

#50 

Air Shutter 

3/16” 

1/2” 

3/16” 

1/2” 

Gas Inlet Size 

S.I.T. 820 Nova, 3/8” NPT 

Gas Supply Pressure  Minimum 

Normal 

Maximum 

Natural Gas 

4.5” 

7” 

9” 

Liquid Propane 

11” 

11” 

12” 

Manifold Pressure 

High 

3.5” w.c. [0.87kPa] 

NG

 

10” w.c. [2.61kPa] 

LP

 

Manifold Pressure 

Low 

1.6” w.c. [0.40kPa] 

6.3” w.c. [1.57kPa] 

 

47

Содержание Marquis Capri IDV34

Страница 1: ...erials from any masonry solid fuel fireplace The IDV34 IDV44 Fireplace Insert was designed for installation in a zero clearance type listed solid fuel burning factory built fireplace It may be necessary to remove the damper plate refractory liners log grates glass door and screen rails mesh Removal of the smoke baffle is necessary in most cases A Division of R Co Inc 2340 Logan Avenue Winnipeg Man...

Страница 2: ...equirements 21 Using Steel Studs and Concrete Board 21 Leveling Instructions Riser Kit 22 Surround Installation 23 Clean View Attachment 24 MQSF1BL or MQDD1BL Attachment 25 I33CS Mantel Clearance Shield 26 Media and Accessories RLT RLH Brick Liner Panels 27 PRL Porcelain Liner Panels 28 Log Placement LOGF35 for IDV33 34 29 Log Placement LOGF36 for IDV44 30 MQRSP4 MQRSP8 Rock and Glass Support Plat...

Страница 3: ... EGTM Remote Controls 55 Proflame 2 IPI Proflame 2 Parts List 56 Proflame 2 IFC Module and Remote Control 57 Cold Climates CPI Setting 58 Proflame 2 Remote Control Operation 59 60 Proflame 2 Schematic 61 Electronic Ignition Lighting Instructions 62 Venting IDVVT IDVVT43 Venting Installation 63 Installation of Vent Pipe 64 Insulation of Chimney Cavity 65 Parts List IDV34 Parts List 66 IDV44 Parts L...

Страница 4: ...NS Insert Hooks on Safety Screen into Slots in Glass Door Frame GLASS DOOR IS INSTALLED ON FIREPLACE SHOWN REMOVED FOR CLARITY ONLY SAFETY SCREENS ARE SUPPLIED IN CV1BL MQCV2BL Kits GLASS DOOR IS INSTALLED ON FIREPLACE SHOWN REMOVED FOR CLARITY ONLY HOOK SLOT HOOK SLOT To remove Safety Screens WAIT UNTIL FIREPLACE IS COMPLETELY COOL Lift up on Safety Screen Frame and disengage Hooks in Safety Scre...

Страница 5: ...he sounds produced by a furnace or heating duct This noise does not affect the operation or longevity of your fireplace It is also normal for the fan to make some noise when it comes on This noise can be reduced somewhat by turning down the speed of the fan with the variable speed control Be aware however that this will reduce the volume of heated air circulated into the room by the fan Note to th...

Страница 6: ...ndition of vent and vent terminal for sooting or obstruction and correct if present 6 Vacuum and clean any debris in the firebox that is not supposed to be there 7 Test and measure the flame failure response time of the flame safety system It must de energize the safety shutoff in no more than 30 seconds Procedure for Millivolt Units Turn on fireplace for 5 minutes Shut off fireplace while listeni...

Страница 7: ... Installation of Vent Pipe section It is recommended to annually inspect and clean the Burner System to prevent malfunction and or sooting This operation should be performed by your dealer or a qualified technician Refer to Burner System Maintenance section Venting systems should be periodically examined by a qualified agency Periodically remove the logs from the grate assembly and vacuum any loos...

Страница 8: ...t annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting bedding material et cetera It is imperative that control compartments burners and circulating air passageways of the appliance be kept clean Make sure that the gas valve and pilot light are turned off before you attempt to clean this unit 16 Clothing or other flammable material s...

Страница 9: ...fication plate shall be mounted at the exterior of the building four feet directly above the location of vent terminal The plate shall be of sufficient size to be easily read from a distance of eight feet away and read Gas Vent Directly Below 2 For direct vent appliances mechanical vent heating appliances or domestic hot water equipment where the bottom of the vent terminal and the air intake is i...

Страница 10: ... the USA and CAN CSA C22 1 Canadian National Electrical Code in Canada An appliance must be grounded to the steel chassis of the home with 8ga copper wire using a serrated or star washer to penetrate paint or protective coating to insure grounding Use carriage bolt at the attachment point see diagram above to secure the appliance to the floor Bedroom approved For required venting components see ve...

Страница 11: ...IDV34 Fireplace Openings REQUIRED DIMENSION A Front Width 28 5 8 B Height 21 1 2 C Depth 17 3 4 D Back Width 21 1 4 IDV34 Fireplace Dimensions A B C D 28 5 8 11 ...

Страница 12: ...34S3927 I34SPF4131 I34SU4541 WIDTH 37 1 8 39 41 1 8 45 HEIGHT 25 3 16 27 5 16 31 3 8 41 DEPTH 1 7 16 1 2 1 2 1 16 To be Custom Cut and Bent NOTE MQ34CV3 Clean Views have a tapered profile Refer to illustrations for frontal dimensions MQ34CV3 Clean Views Require either a Frame Door MQ34SF1BL or a Heavy Iron Door MQ34DD1BL MQ34CV4PFBL I34S3927 I34SPF4131 I34SU4541 WIDTH 37 1 8 39 41 1 8 45 HEIGHT 27...

Страница 13: ... WITH I34S3927 MQ34CV3 WITH I34S3927 MQ34CV4PF WITH I34SPF4131 NOTE Clean View Hooks are adjustable 1 4 for uneven wall surface MQ34CV3 WITH MQ34DD1 or MQ34SF1 DOOR MQ34CV4PF WITH MQ34DD1 or MQ34SF1 DOOR 1 5 16 1 13 16 2 2 1 5 16 MQ34CV2 35 5 8 13 ...

Страница 14: ...versal Surround IDV34 For use with I34CV1BL MQ34CV2BL MQ34CV3BL and MQ34CV4PFBL This Surround can be custom cut and bent Cut Surround at dotted line shown above to make the bottom flush with the fireplace bottom 14 ...

Страница 15: ... Surround and I33CS Mantel Shield A 0 36 30 B 2 38 1 2 32 C 4 40 1 2 34 D 6 42 1 2 36 E 8 44 1 2 38 MQ34CV2 Combustible Mantel Heights Dimension Mantel Depth MQ34CV2 Only or with Surround MQ34CV2 with Surround and I33CS Mantel Shield A 0 32 28 B 2 34 30 C 4 36 1 2 32 D 6 38 1 2 34 E 8 40 36 MQ34CV3 MQ34CV4 Combustible Mantel Heights Dimension Mantel Depth MQ34CV3 MQ34CV4 Only or with Surround MQ34...

Страница 16: ...IDV44 Fireplace Openings REQUIRED DIMENSION A Front Width 32 7 8 B Height 25 3 4 C Depth 18 D Back Width 25 3 4 IDV44 Fireplace Dimensions A B C D 16 ...

Страница 17: ...44S4432 I44SPF4436 I44SU4742 C W Safety Screen WIDTH 39 5 8 44 44 47 HEIGHT 29 1 16 32 1 16 36 42 DEPTH 1 5 16 1 2 1 2 1 16 To be Custom Cut and Bent MQ44CV3BL I44S4432 I44SPF4436 I44SU4742 WIDTH 41 7 16 44 44 47 HEIGHT 29 1 8 32 1 16 36 42 DEPTH 1 7 16 1 2 1 2 1 16 To be Custom Cut and Bent NOTE MQ44CV3 Clean Views have a tapered profile Refer to illustrations for frontal dimensions MQ44CV3 Clean...

Страница 18: ...44CV1 WITH I44S4432 MQ44CV2 WITH I44S4432 MQ44CV3 WITH I44S4432 NOTE Clean View Hooks are adjustable 1 4 for uneven wall surface 1 5 16 1 5 16 1 13 16 1 7 16 2 MQ44CV3 WITH MQ44DD1 MQ44SF1 DOOR MQ44CV2 39 15 16 39 5 8 18 ...

Страница 19: ...42 Universal Surround IDV44 For use with I44CV1BL MQ44CV2BL and MQ44CV3BL This Surround can be custom cut and bent Cut Surround at dotted line shown above to make the bottom flush with the fireplace bottom 19 ...

Страница 20: ...ss the non combustible mantel meets the minimum height and width requirements for a combustible mantel I44CV1 Combustible Mantel Heights Dimension Mantel Depth I44CV1 Only or with Surround I44CV1 with Surround and I33CS Mantel Shield A 0 40 34 B 2 42 36 C 4 44 38 D 6 45 40 E 8 46 42 MQ44CV2 Combustible Mantel Heights Dimension Mantel Depth MQ44CV2 Only or with Surround MQ44CV2 with Surround and I3...

Страница 21: ...flush with the finishing materials and the clean view kit is proud of the finished non combustible enclosure wood burning fireplace Combustibles must be above Combustible Mantel Line This area must have Non Combustible materials ONLY 1 2 MIN Clearance required to remove Clean View Combustible Mantel Line Side Wall Clearance from edge of Clean View Kit 2 TOP VIEW Floor beneath appliance must be non...

Страница 22: ...Model No I34R40 I44R45 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Right Side View Measure Height Leveling Leg Leveling Legs Locate slots at bottom front of unit Place riser assembly under front of insert and fasten to base with supplied screws Measure...

Страница 23: ...CV2 Attachment CV3 CV4PF Attachment PARTS LIST Surround Qty 4 6 Black Screws FRONT VIEW STEP 1 Place Surround against back of Clean View STEP 2 Fold Tabs on Clean View over surround and install with 4 screws supplied with surround Surround STEP 1 Place Surround against back of Clean View Surround STEP 2 Install with 4 screws supplied with surround FRONT VIEW BACK VIEW BACK VIEW 23 ...

Страница 24: ...e CV Kit before it is mounted SECTION 2 Clean View Mount Slots are located beside the Safety Screen Frame on the Fireplace Insert the 4 Clean View Mount Hooks into the Clean View Mount Slots and lower the Clean View into place SECTION 3 Millivolt Systems Install ON OFF Switch into right side of Clean View See below ON OFF Switch Surround Mount Tabs Mounting Hooks Clean View Optional Surround Clean...

Страница 25: ...n View Mount Slots Step One Remove Top Screw from upper left corner of Clean View Step Two Place MQSF1 or MQDD1 Door onto Screw at lower inside left corner of Clean View Step Three Align Top Slot and reinsert screw Press and hold Hinge Plate to the Left side of Clean View and tighten screws Step Four Set Stopper Screws on right side of Clean View so that door is flush when closed Hinge Plate 25 ...

Страница 26: ...tions Place I33CS upside down on a protected surface Loosen screws Center surround onto I33CS Tighten screws to hold surround in place Surround is now ready to install onto Clean View Contents of Kit 1 Mantel Clearance Shield c w Screws 26 ...

Страница 27: ...de and tilt Back Panel to remove To Install 1 Fold up tabs in upper baffle 2 Install rear brick panel first 3 Install left and right side panels and secure them with brick clips 4 Replace Log Supports Parts List 1 Back Panel 1 Right Side Panel 1Left Side Panel Log Supports Back Panel Baffle Tab Baffle Tab Upper Baffle 27 ...

Страница 28: ... the Brick Clips in place 3 Tilt and slide the Side Panels into place Reinstall the 2 DT Screws without the Brick Clips 4 Replace Log Supports Parts List 1 Back Panel 1 Right Side Panel 1Left Side Panel Log Supports Back Panel Left Side Panel Right Side Panel Note Warping and Discoloration of Porcelain or Painted Metal Liners Is Not Covered Under Warranty Both Porcelain and Painted Metal Liners ma...

Страница 29: ...of the log mounting pan as shown in the picture above Log C has to be lowered into position just behind Logs A and B Log C shall be pulled up to Logs A and B as shown in the picture above A bag of Ember Chunks is supplied with the appliance It is very important that these chunks are placed onto the front burner and log mounting pan as shown in the picture Spread the Ember Chunks out no more than o...

Страница 30: ...ce Log 3 onto right side of Log 1 Locate 2 holes on bottoms of Logs 4 and 5 and position onto mounting pins Locate 1 hole on the bottom of Log 6 and place it onto pin of Log 2 Locate 2 holes on the bottom of Log 7 and place onto the pins of Log 5 Place Glow Ember Kit onto front burner tube and ember plates Lava Rock and Vermiculite are to be placed onto firebox ONLY 30 ...

Страница 31: ... over burner MQRSP4 MQRSP8 Parts List MQRSP4 Rock Support Ember Plates Assembly Pilot Shield Base Unit As Shipped One screw from the Fan Access Cover Plate is all that is required to mount the RSP4 Fan Access Cover Plate Firebox Bottom Parts List MQRSP8 Tray and 1 Pilot Shield Pilot Shield should be visually inspected monthly for signs of deterioration due to flame exposure Replace if necessary 31...

Страница 32: ...mber plates into place as shown in the illustration above Step 1 Place Rocks 4 into position as shown Be sure not to place them directly over top of the burner tube Step 2 Place Rocks 1 into position as shown above Step 3 Place Rocks 4 into position as shown above WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this ap...

Страница 33: ...on as shown above Step 6 Place Rocks 1 into position as shown above Step 7 Place Rocks 3 and 4 into position as shown above Finished Rock Set and Burn NOTE If flame impingement on the rocks causes sooting then you may have to move or remove one or more rocks DO NOT PLACE ROCKS DIRECTLY OVER TOP OF THE BURNER TUBE 33 ...

Страница 34: ... Rock supplied with unit around firebox bottom WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury Pilot Shield should be visually inspected monthly for signs of deterioration due to flame exposure Replace if necessary Verify ignition of pilot and main burner ...

Страница 35: ...n listed below can alter the performance of the unit and is not covered under warranty Note Use only 1 2 glass material on the burner Ember Glass Material from American Fireglass Maximum amount for MQRSP8 Natural Gas is 5 lbs Propane units 5 lbs Maximum amount for RSP10 Natural Gas is 15 lbs Propane units 15 lbs MQ Ember Maximum amount for MQRSP8 is 3 bags Not used on RSP10 Discoloration of glass ...

Страница 36: ...r Installation page for further details Base Unit As Shipped Glass Retainer Pilot Shield Parts List RSP10 Tray and 1 Pilot Shield Glass Retainer 25 1 2 for IDV34 Glass Retainer 30 for IDV44 15LBS Bronze Glass Glass Retainer Lava Rock supplied with unit may be used as a filler beneath Glass Embers on sides of firebox WARNING Failure to position the parts in accordance with these diagrams or failure...

Страница 37: ...d area See Glass Ember Installation page for further details Base Unit As Shipped Retainer Pilot Shield MQRSP11 Parts List 1 Tray and 1 Pilot Shield 1 Glass Retainer 25 1 2 for IDV33 30 for IDV43 2 Small Bags Lava Rock 1 Bag 350 Ember Retainer Lava Rock supplied with unit may be used as a filler on sides of firebox WARNING Failure to position the parts in accordance with these diagrams or failure ...

Страница 38: ...ly parts specifically approved with this appliance may result in property damage or personal injury STEP 1 Fill bottom of firebox around tray with Lava Rock and place LOG 1 against back wall as shown STEP 2 Place LOG 2 in center right side of H Burner as shown STEP 3 Place LOG 3 on left side of firebox as shown STEP 4 Place LOG 4 along back wall as shown 350 Embers 3 4 Lava Rock LOG 1 LOG 4 LOG 5 ...

Страница 39: ...STEP 5 Place LOG 5 in front of LOG 2 as shown STEP 5 Place 350 Embers on and around burner Sprinkle Vermiculite onto Lava Rock on firebox bottom LOG 5 LOG 2 350 EMBERS 39 ...

Страница 40: ... motor 4 When resealing the Fan Access Panel use High Temp Silicone or Millpac 1 Remove glass door assembly and log set if installed Be sure to handle logs carefully as they become fragile after heated 2 Remove back air shield by unscrewing 4 screws 3 Remove fan access panel 15 screws It is located on the back and bottom right hand corner 4 Remove the fan from the outer shell 2 screws The fan need...

Страница 41: ... the burner assembly Once the screws are all removed the latches will either fall or slide out 3 To remove the spring unfasten the one 1 lock nut holding it in place NOTE When replacing a spring tighten the lock nut so that the total compression length is 3 1 2 This is critical for proper tension IDV34 IDV44 Glass Door Removal and Installation 1 Disengage Top Latches by pulling on Latch Pull with ...

Страница 42: ...ews around the outside of the burner pan This will remove the entire burner assembly 4 When removing the entire burner assembly break the seal and lift upwards Make sure the gas line to the unit has been disconnected 5 To reinstall the burner assembly ensure the surfaces are cleaned and old sealant material removed Use high temp Millpac to seal and secure with the twelve 12 screws 6 Reconnect the ...

Страница 43: ...ctions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator 34IDV CKLP 44IDV CKLP LP Conversion Millivolt 1001 P167SI 30 977 167 51 50 1000 253closed 1000 253closed 1 2 1 2 1001 P202SI 1001 P202SI 34IDV CKNG 44IDV CKNG NG Conversion Millivolt 1001 P165SI 51 977 165 35 32 1000 253closed 1000 253closed 3 16 3 16 1001 P201SI 1001 P201SI 34...

Страница 44: ... to the bracket 6 Remove the 2 screws that attach the pilot bracket to the firebox bottom 7 Remove the pilot bracket to expose the pilot assembly 8 Remove the pilot tube and nut from the pilot assembly using a 10mm wrench slide the tube and nut down You may have to tap the pilot hood lightly to release the pilot orifice Place new pilot orifice into the pilot assembly and reinstall the pilot tube a...

Страница 45: ...jector near the top LPG injectors have a groove machined around their circumference near the top while NG injectors do not have a groove fig 4 Refer to the Appliance Manufacturer s instruction sheet for the proper injector size 6 Insert the Allen wrench into the end of the injector Then insert the injector into injector journal and rotate the injector clockwise until a torque of 9 lbf in 1 0 Nm is...

Страница 46: ...Gas Conversion for Modulator PART C 46 ...

Страница 47: ...izes 6 Ports are accessible for test gauge connection both on the inlet and outlet of the gas valve 7 Turn the gas supply ON and check for leaks DO NOT USE OPEN FLAME FOR THIS PURPOSE Use an approved leak testing solution 8 The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of ...

Страница 48: ...w observe closely the pilot burner located on the rear center left hand side of the main burner If a flame has appeared then continue to depress the control knob for 20 seconds If the flame did not appear then continue to depress the red igniter button every 5 seconds until a flame is established NOTE If after 30 seconds a flame has not yet been established then turn the control knob back to the o...

Страница 49: ...age Check generator with millivolt meter Take reading at generator terminals of gas valve Should read 325 millivolts minimum while holding valve knob depressed in pilot position and wall switch off Replace faulty generator if reading is below specified minimum Plugged burner orifice Check burner orifice for stoppage and remove Pilot burning no gas to burner valve knob ON and wall switch ON Defecti...

Страница 50: ...n press the Thermostat Key The LCD display on the Transmitter will change to show that the room thermostat is ON and the set temperature is now displayed To adjust the set temperature press the Up or Down Arrow Keys until the desired set temperature is displayed on the LCD screen of the Transmitter Smart Thermostat Transmitter Operation The Smart Thermostat function adjusts the flame height in acc...

Страница 51: ...ating Servo Motor Is an add on valve component that permits HI LO functionality to be controlled by the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to operate without the need for an external AC Adapter power source The advantage to using the battery back...

Страница 52: ...Now the circuit is complete So the way it works is that electrical power is supplied to the Remote Receiver module and then proceeds to the Main IPI module Furthermore note that a Backup Battery Pack is not required in this configuration Instead batteries in the Remote Receiver act as the backup supply NOTE The Remote Receiver module can also be located outside of the appliance to a maximum of 6ft...

Страница 53: ...sor 1002 P910si Electrode Flame Sensor 35 Length 5 1002 P302si IPI Ignition Board 6 1002 P850si AC Wall Adapter 7 1002 P12BH Battery Pack 8 1002 P912si Wiring Harness 9 1001 P166si Orifice Pilot NG 62 1001 P168si Orifice Pilot LP 35 10 1002 P013si Stepper Motor NG 1002 P012si Stepper Motor LP 1002 P016si Hi Lo Regulator NG 1002 P014si Hi Lo Regulator LP Models ZRB46E MQRB4436E MQRB5143E MQRB6961E ...

Страница 54: ...N OFF and manual HI LO capabilities OPTIONAL For units with remote HI LO capabilities a modulating servo is required to be installed on the valve The connectors to this servo must be connected to the Remote Harness as shown in the figure above Receiver Module 0 584 523 521 221 1001 P221SI 54 ...

Страница 55: ...PI or Millivolt system can be powered by the AC Adapter This is advantageous if you do not want to use batteries Simply connect the AC Adapter into the Remote Control Wiring Harness as per the diagrams below IPI System EGTM Receiver Module 0 584 523 521 221 1001 P221SI Millivolt System GTM Receiver Module 0 584 523 521 221 1001 P221SI In the U S A Thermostats are not permitted for Vented Gas Firep...

Страница 56: ...3 13 1002 P047SI TC Pilot Burner IPI Assembled LP 199 047 14 1001 P166SI TC Orifice Pilot NG 977 166 62 IPI 15 1001 P168SI TC Orifice Pilot LP 977 168 35 IPI 16 1001 P280SI TC Tubing W Fittings 1 8 2 182 280 17 1002 P012SI IPI Stepper Kit LP 907 012 18 1002 P013SI IPI Stepper Kit NG 907 013 19 1002 P014SI IPI Reg Kit LP Hi Lo 907 014 20 1002 P016SI IPI Reg Kit NG Hi Lo 907 016 21 1002 P017SI TC El...

Страница 57: ... must be followed to reset the PF2 Module Press the Red SW1 button until you hear three beeps Within 10 seconds press the SW1 button again until you hear it beep The PF2 Module may now be turned on off manually x4 connector by a switch not supplied the pilot will remain on CPI continuous pilot ignition mode all other functions of main burner fan and lights will be on the high setting Fan Startup a...

Страница 58: ...3 Press UP on the UP DOWN Arrow Key Display will show CPI The module in the fireplace will beep once to confirm command TO RETURN TO IPI INTERMITTENT PILOT MODE Repeat steps one and two and then press DOWN on the UP DOWN Arrow Key The module in the fireplace will beep once to confirm command Lockout Reset Procedures Proflame 2 If the fireplace has cycled too many times in a short period of time it...

Страница 59: ...Proflame 2 Remote Control 59 ...

Страница 60: ...Note When Smart Thermostat is activated manual flame height adjustment is disabled Note This function is only available in Room Thermostat or Smart Thermostat Control Mode 60 ...

Страница 61: ...61 ...

Страница 62: ...re department LIGHTING INSTRUCTIONS 1 Stop Read the above safety information on this label 2 Remove batteries from receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This fireplace is equipped with an ignition device which automatically lights the pilot Do not try to light the pilot by hand 5 Open the glass door 6 6 Turn manual shutoff valve clockwise to off Locat...

Страница 63: ...wn the vent and screw the seal plate to the chimney crown clay tile chimney or wood stove vent It may be necessary to predrill holes into the chimney crown depending on material 8 screws Vertical Venting in Cold Climates In cold climate conditions where temperatures go below 10 C 14 F we recommend that the chase be insulated and where the vent pipe enters into the attic space that the pipe be wrap...

Страница 64: ...oned 3 Slide the unit into place carefully Ensure that the adapter slides along the top of the unit in between the guides and check that it remains flat Fig 2 4 Once the unit is slid back into position use the two screws previously removed to secure the adapter plate When tightening the adapter plate check to make sure the plate is flat to the unit and the rear catch lock is engaged over the rear ...

Страница 65: ... quickly and the flames lift off the burner If this is the situation we recommend you switch to continuous pilot cold climate mode This will keep the cavity warm and will create a slight draft in the vent allowing for the burner to light quickly and draft correctly Condensation on Glass after Startup certain installations may encounter excessive fogging on the window after startup not just the fir...

Страница 66: ...RONTS I34CV1BL Clean View Black c w Safety Screen 35 1 4 W x 24 3 16 H x 13 16 D MQ34CV2BL Clean View Black c w Safety Screen 35 3 8 W x 24 11 16 H x 1 3 4 D MQ34CV3BL Clean View Black 37 1 8 W x 25 3 16 H x 1 7 16 D When using a I34CV3 a Designer Door or Door Frame is Required MQ34CV4PFBL Clean View Picture Frame Black 37 1 8 W x 27 3 8 H x 1 7 16 D When using a I34CV4 a Designer Door or Door Fra...

Страница 67: ...NE Decorative Stones MQSTONE10 Decorative Stones 10 PCE Set IDV44 CLEAN VIEW FRONTS I44CV1BL Clean View Black C W Safety Screen 39 9 16 W x 28 1 2 H x 13 16 D MQ44CV2BL Clean View Black C W Safety Screen 39 5 8 W x 29 1 16 H x 1 3 4 D MQ44CV3BL Clean View Black 41 7 16 W x 29 1 8 H x 1 7 16 Depth DOORS FOR MQ44CV3BL MQ44SF1BL Door Frame c w Safety Screen MQ44DD1BL Designer Door Series 1 c w Safety...

Страница 68: ...SIT 1001 P144SI Nut Electrode Universal Bushing 974 144 IPI ELECTRONIC IGNITION PARTS 1006 P002SI Valve IPI Proflame PF1 886 002 NG HI LO 1006 P003SI Valve IPI Proflame PF1 886 003 LP HI LO 1002 P322SI IPI Module PF1 584 322 1002 P850SI IPI Power Adapter IPI 584 850 AC 1002 P905SI IPI Wire Harness for EGT Remotes 584 905 1002 P912SI IPI Wire Harness for Module 584 912 IPI PROFLAME 2 COMPONENT PART...

Страница 69: ...e IDV44 33IDV 123 Replacement Spring for Door Latch Lower 36HB 123 Replacement Spring for Door Latch Upper 33IDV 123A Latch Assembly Lower 33IDV 123AU Latch Assembly Upper OFP42SA Spark Assist FP15GC Stainless Steel Gas Connector PARTS FOR IDV34 VENTING PART NO DESCRIPTION IDVVT36 Vertical Termination Collinear 3 3 IDVFK25 3 Diameter 2Ea Unexpanded 25ft Flex Pipe Screws Washers Millpac IDVLCP Lowe...

Страница 70: ... other than in a normal residential environment c damages caused by any unauthorized alteration or repair of the unit affecting its stability or performance d damages caused by improper matching or application of the unit or the unit s components e damages caused by failing to provide proper maintenance and service to the unit f any expenses incurred for erecting disconnecting or dismantling the u...

Отзывы: