IDV34 / IDV44 – Wall Coverings, Side Walls and Hearth Requirements
Refer to Mantel Heights Charts for your minimum mantel height.
Using Steel Studs and Concrete Board
Brick facing may be removed and replaced with non-combustible materials such as steel studs and concrete board. The
opening between the firebox and non-combustive materials must be sealed so as the heat cannot run between the face of
the wood fireplace and the re-facing materials.
Insert must be pulled out so the appliance is flush with the finishing materials and the clean view kit is proud of the finished
non-combustible enclosure (wood burning fireplace).
Combustibles must be
above Combustible
Mantel Line
This area must have
Non-Combustible
materials ONLY
1/2” MIN
Clearance
required to remove
Clean View
Combustible Mantel Line
Side Wall Clearance
from edge of Clean
View Kit
2”
TOP VIEW
Floor beneath
appliance must be
non-combustible.
Combustible
Hearth Allowed
Use steel studs
Use concrete board on front and
around steel stud enclosure for insert
Must be sealed to avoid heat
entering old enclosure
Existing zero clearance wood
burning / masonry fireplace
Must be sealed to avoid heat
entering old enclosure
21