ZCV34 Venting - Cathedral Ceiling
Just as with a normal ceiling, an
Attic Insulation Shield
must be
installed where the fireplace vent passes from a lower living space into
an attic space when installing a fireplace into a room with a cathedral
ceiling. This will keep insulation and other combustibles away from the
vent pipe. A
Support Box
must be built in order to install the Attic
Insulation Shield correctly.
A
Fire Stop
must be installed on the bottom side of joists when
passing through an uninsulated ceiling or floor.
Option 1 - Angled Chase Opening
Option 2 - Horizontal Chase Opening
1/2” Plywood Support Box
*B
ased on 24”
truss spacing
Hole may be cut
anywhere along
centerline
FDVVT40
Termination
ZDVRS Roof
Support
Attic Insulation Shield
ZDVAIS or Z7AIS24
2” Opening
on 3 Sides
ZDVFS
Firestop
MIN 1”
Clearance
to Vertical
Vent
ZDVFS Firestop -
Hole may need to
be elongated to due to ceiling angle.
ZDVAIS or Z7AIS24 Attic
Insulation Shield
Hole may be cut
anywhere along
centerline
1/2” Plywood Support Box
Same width and depth
as fireplace chase
VARIABLE
18” MIN
Perpendicular
Wall
24” MIN
1/2”
Plywood
Support
Box
1/2” Plywood
Support Box
24” MIN
FDVVT40
Termination
18” MIN
ZDVRS Roof
Support
Attic Insulation Shield
ZDVAIS or Z7AIS24
1/2”
Plywood
Support
Box
2” Opening
on 3 Sides
1/2”
Plywood
Support
Box
WARNING: HEAT CANNOT BE DISCHARGED
INTO THE WALLS, FLOOR, OR CEILING.
Heat
must exit through the required
2” opening at the top
of the chase.
Use Hi Temp Sealant.
Insulate Attic Insulation Shield with non-
combustible mineral wool insulation, and attach and
seal outer perimeter to the existing vapor barrier.
Perpendicular
Wall
MIN 1”
Clearance
to Vertical
Vent
85