ZCV34 Framing Dimensions for Non-Vented Chase Built Outside of Room
Fireplace is installed As Shipped, with Ventilation Plates in place.
Determine whether face of fireplace will be flush with framing or finished wall.
Refer to Nailing Tab Guide also.
NOTE:
These structures are not load bearing.
Fig.1
Framing for Horizontal Vent
Termination
(See
Installation of Side
Wall Venting
Section)
Vertical Venting MUST maintain 1”
clearance to combustibles.
Framing Depth:
18-
1/8” for Framing flush with face of unit.
17-5/8
” for 1/2” Non-Combustible facing
flush with face of unit.
No loose Combustibles (wood, wiring, etc.)
are allowed inside the Chase area.
RIGHT SIDE VIEW
40” MIN FOR NG
52” MIN FOR
PROPANE
48
” MIN FOR NG
60
” MIN FOR
PROPANE
Chase built outside of
room (Doghouse)
TOP VIEW
Z58WTS Wall
Thimble Shield
Must be used in
Non-Vented
Chases with
Horizontal Venting.
Chase built outside
of room (Doghouse)
16