ZCV34 Clearance to Combustibles for Vented Chase
Ventilation Plates must be removed before installation into a Vented Chase
Front
36” [92cm]
*Note:
If appliance is installed
directly on carpeting or other
combustible material other than
wood flooring, a metal or wood
panel extending the full width and
depth of the appliance must be
used. Carpet may extend 1 inch
above the floor of the appliance.
Back (from Stand-offs)
0” [0cm]
Side (from Stand-offs)
0” [0cm]
Floor
*
(See
Note
)
0” [0cm]
Minimum Ceiling / Enclosure Height (from bottom
of fireplace)
6
8” [173cm] Natural Gas
68
” [173cm] Propane
Top (from Stand-offs)
0” [0cm]
Adjacent Wall
1/1/2” [3.8cm]
Top of 90° Bend in minimum Enclosure
28
” [71cm] Natural Gas
16” [40.6cm] Propane
Top of 90° Bend inside Enclosures above
minimum height
4-
1/2”
VENTING SYSTEMS
Top of Horizontal Pipe
1/1/2” [3.8cm]
Side & Bottom of Horizontal Pipe
1” [2.5cm] All Vent Systems
Vertical Vent Pipe
1” [2.5cm] All Vent Systems
-Remove Ventilation Plates-
Top of Fireplace Must be
Converted for Vented Chase
Installation.
Materials
covering face of
appliance can be
combustible
40” MIN
FOR NG
52” MIN
FOR
PROPANE
6
8”
MIN
Chase must be Vented
using grills or open top.
Chase must be Vented
using a grill or open top.
Inside walls of the chase
MUST
be drywalled.
-Remove Ventilation
Plates-
See
Removal of Vent
Covers
on Page 14.