FDV/FV/FVF 300 OPTIONAL FAN KIT INSTALLATION
PARTS LIST:
- Mounting bracket
(4000-5000 only)
- 1 Variable speed control
with 2 male ends
- 1 black knob
- 1 speed nut
- 2 fan mounting screws
NOTE:
THE FAN ADAPTER IS NOT USED ON 300 MODEL UNITS. (DISCARD THIS ITEM.)
NOTE:
FOR EASE OF INSTALLATION, THE FAN KIT SHOULD BE INSTALLED BEFORE THE
STOVE IS PUT IN ITS FINAL POSITION.
AUTOMATIC ON/OFF THERMOSTAT CONTROLLED FAN KIT (Part #F35FK)
1. Install variable speed control onto the control panel. It will be located beside the valve controls. Be sure
to route the wires from the speed control through the 3/4” plastic grommet located on the left side of the
panel.
2. Locate the two fan mounting screws in the rear of the unit as shown in the above diagram and place the
key holes on the rear of the fan over the mounting screws and drop into position.
3. Connect the power, sensor and variable speed control as shown in the wiring diagram.
4. Turn the switch on (clockwise). NOTE: The stove must now be installed and gas line attached before
proceeding.
5. Turn the stove on. Once the sensor unit reaches operating temperature (in approximately 10 to 15
minutes) the fan will turn on. The fan can be switched off if desired by turning the switch fully counter-
clockwise.
6. Once the fan has started to turn it may be desirable to adjust the minimum fan speed. Tilt the control
panel forward to access the rear of the variable speed switch, turn the variable speed switch to its
minimum setting (fully clockwise). Use the set screw on the side of the variable speed control to increase
or decrease the minimum fan speed. (It may be desirable to lower minimum fan speed to decrease the
sound level created by the fan.) Reinstall the control panel.
WARNING
Label all wires prior to disconnection
when servicing controls. Wiring
errors can cause improper and
dangerous operation. Verify proper
operation and servicing.
WARNING
Electrical Grounding Instructions - This
appliance is equipped with a three - pronged
(grounding) plug for your protection against
shock hazard and should be plugged directly
into a properly grounded three-prong
receptacle.
WARNING
A qualified electrician must
connect electrical wiring to
junction outlet for built-in
installation.
Follow all
codes.