Gas fired appliances may be used only for supplemental heat and/or decorative purposes and under no circumstances shall they 
provide a primary heat source. 

 

This appliance must not be connected to a chimney flue serving a separate solid-fuel burning appliance.  

 
 

NOTE: It is recommended that a Carbon Monoxide (CO) Detector be installed in or near bedrooms and on all levels of your home. 
Place a detector about 15ft [4.5m] outside the room that houses your gas appliance. 

Certified for installation in a bedroom or bed/sitting room. In Canada must be installed with listed millivolt thermostat. 

 In the U.S.A. Thermostats are not permitted for Vented Gas Fireplaces (ANSI Z21.50b-2009 -Decorative). 

  In USA see local codes. 

 

Operations and Maintenance Instructions 

For safe installation and operation note the following: 

• 

The Burner/Log Assembly has been engineered and permanently adjusted for proper flame control. 

• 

Periodically remove the logs from the grate assembly and vacuum any loose particles from the grate and burner areas. See Log 
Placement page to remove logs. Vacuum burner parts and replace logs. 

• 

Never use your gas fireplace as a cooking device. 

• 

Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify 
proper operation after servicing. 

Installation Requirements for the Commonwealth of 
Massachusetts 

In the Commonwealth of Massachusetts, the installer or service agent shall be a plumber or gas fitter licensed by the Commonwealth. 

When installed in the Commonwealth of Massachusetts or where applicable codes; the unit shall be installed with a CO detector per the 
requirements listed below. 

1. 

For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment, where the bottom of the vent 
terminal and the air intake is installed below four feet above grade the following requirements must be satisfied: 

A. 

If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm 
shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 
(2005 Edition). 

B. 

A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall: 

 

Be powered by the same electrical circuit as the appliance or equipment such that only one service switch services 
both the appliance and the carbon monoxide detector; 

 

Have battery back-up power; 

 

Meet ANSI./UL 2034 Standards and comply with NFPA 720 (2005 Edition); and 

     Have been approved and listed by a Nationally Recognized Testing Laboratory as recognized under 527 CMR. 

C. 

A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used. 
Installation shall be in strict compliance with the manufacturer’s instructions. A copy of the installation instructions shall 
remain with the appliance or equipment at the completion of the installation. 

D. 

A metal or plastic identification plate shall be mounted at the exterior of the building, four feet directly above the location of 
vent terminal. The plate shall be of sufficient size to be easily read from a distance of eight feet away, and read “Gas Vent 
Directly Below”. 

2. 

For direct-vent appliances, mechanical-vent heating appliances or domestic hot water equipment where the bottom of the vent 
terminal and the air intake is installed above four feet above grade the following requirements must be satisfied: 

A. 

If there is not one already present, on each floor level where there are bedroom(s), a carbon monoxide detector and alarm 
shall be placed in the living area outside the bedroom(s). The carbon monoxide detector shall comply with NFPA 720 
(2005 Edition). 

B. 

 A carbon monoxide detector shall: 

 

Be located in the room that houses the appliance or equipment; 

 

Be either hard-wired or battery powered or both; and 

 

Shall comply with NFPA 720 (2005 Edition). 

A Product-approved vent terminal must be used, and if applicable, a Product-approved air intake must be used. Installation shall be in 
strict compliance with the manufacturer instructions. A copy of the installation instructions shall remain with the appliance or equipment 
at the completion of the installation. 

 

For the state of Massachusetts a 

T-handle gas shut-off valve

 must be used on a gas appliance. This T-handle gas shut-off valve must be listed and 

approved by the state of Massachusetts. This is in reference to the state of Massachusetts state code CMR238. 

 

6

Содержание FDV200

Страница 1: ...Horizontal installations the venting must be a minimum of one foot vertical off the flue before going horizontal Installation Instructions Model Number FDV200 FDV200P Free Standing Direct Vent Gas St...

Страница 2: ...sed with the installations e g marble tile and the adhesives used to adhere this product to the walls can react with heat and cause odours It is recommended that you burn your gas fireplace or stove f...

Страница 3: ...Panel Kit 11 Installation Instructions for LOGC200 12 Optional Fan Kit Installation 13 Millivolt System Lighting and Burner Control 14 Burner System Maintenance 15 Conversion Kit Instructions Part A...

Страница 4: ...stallation of appliance or venting For required venting components see venting installation in appropriate section of this manual 4 THE FDV200N FDV200PN FDV200LP and FDV200PLP MAY BE INSTALLED IN MANU...

Страница 5: ...the appliance 15 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent...

Страница 6: ...A 720 2005 Edition B A carbon monoxide detector shall be located in the room that houses the appliance or equipment and shall Be powered by the same electrical circuit as the appliance or equipment su...

Страница 7: ...liance may be installed directly on carpeting tile or other combustible material with no additional floor protection being required This unit has been tested in a Alcove the minimum size of Alcove is...

Страница 8: ...IG 3 5 KPa 9 The appliance must be isolated from the gas supply piping system by closing its individual shutoff valve during any pressure testing of the gas supply piping system at test pressures equa...

Страница 9: ...DV200 FDV200P NG LP GAS SPECIFICATIONS 9 35 51 3 8 FULL OPEN GAS INLET SIZE 3 8 SIT FUEL GAS MAXIMUM INPUT CONTROL BTU HIGH LOW NATURAL GAS MILLIVOLT 30 000 20 000 PROPANE GAS MILLIVOLT 26 000 20 000...

Страница 10: ...paper cardboard coal be used in this appliance NOTE it is normal for your gas stove to give off some odour the first time it is burned This is due to the curing of the paint and any undetected oil fr...

Страница 11: ...k clip out of the way and position side brick against rear brick panel and side of firebox Now swing clip onto panel and tighten screw 4 Install log set and glass door WARNIING Do not operate applianc...

Страница 12: ...n picture and slide Log 3 forward up to the locating tabs 3A 3B Do not place log on top of tabs Step 4 Place Log 4 onto notched areas of Logs 1 3 Step 5 Place Log 5 up against 2nd Grate Bar from the l...

Страница 13: ...it reaches operating temperature in approximately 10 to 15 minutes the fan will turn on The fan can be switched off if desired by turning the switch fully counter clockwise 6 Once the fan has started...

Страница 14: ...above on this label If you don t smell gas then go to the next step 7 Now push in the control knob slightly and turn 4 counter clockwise to the PILOT position 8 Push in the control knob all the way a...

Страница 15: ...peration Flame should appear similar to the above picture Conversion Kit Instructions PART A Kit Number Description Pilot Orifice Burner Orifice Brass 1000 255 Brass Nipple Air Shutter Hi Lo Regulator...

Страница 16: ...to convert the valve from one type of fuel to the other Step 8 Check for gas leaks around the pilot burner tube and face of valve Step 9 Attach conversion label to label plate on bottom of unit writi...

Страница 17: ...e new injector is proper for the application The injector size is stamped on the side of the injector near the top LPG injectors have a groove machined around their circumference near the top while NG...

Страница 18: ...Gas Conversion for Modulator PART C WARNING WARNING 18...

Страница 19: ...the remote Contrary to this feature is a Manual HI LO Control Knob The Modulating Servo Motor requires the Remote system to be present Backup Battery Pack This component permits the IPI system to oper...

Страница 20: ...ol wiring harness instead of the main IPI harness From the Remote wiring harness use its male plug in connector and connect it to the female plug in in the main IPI harness Now the circuit is complete...

Страница 21: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 21...

Страница 22: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 22...

Страница 23: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 23...

Страница 24: ...ent LIGHTING INSTRUCTIONS 1 STOP Read the above safety information on this label 2 Remove batteries from Receiver and or Battery Backup Pack 3 Turn off all electric power to the fireplace 4 This firep...

Страница 25: ...inches 45cm N Clearance to perpendicular wall 24 inches 60 cm Recommended to prevent re circulation of exhaust products For additional requirements check local codes V NOTE Clearances are to the edge...

Страница 26: ...ing and Simpson Duravent venting Minimum clearances on venting 4 to top of elbow 2 1 2 from top of horizontal pipes 1 on all other existing pipes REMEMBER THAT A 1 4 VERTICAL RISE IS REQUIRED FOR EVER...

Страница 27: ...um stove performance HOW TO USE THE VENT TABLE 1 Determine the height of the system and the number of elbows required 2 Use the Venting Chart to determine the maximum horizontal distance allowed Total...

Страница 28: ...sealant MIL PAC SEALANT IS RECOMMENDED to the pipe and secure it with the 4 screws washers If two pieces of 4 flex pipe are to be joined the joint must be siliconed and secured with four 4 screws Befo...

Страница 29: ...be unavoidable is when installing the vent terminal Note Do not remove or move spacer springs attached to 4 inner flex pipe these must be used to assure an 1 1 4 air gap between 4 and 7 pipes Minimum...

Страница 30: ...VENTING AIR INTAKE PLATE ADJUSTMENT NOTE Unit comes preset for vertical venting under 15 feet Follow these instructions when venting exceeds 15 feet vertical 1 Locate the 3 x 1 4 hex screws and using...

Страница 31: ...e an offset in order to avoid cutting of joists and to clear other obstructions When using 45 elbows an elbow support is required directly above the highest elbow When installing a bend in a joist are...

Страница 32: ...ane On Off Hi Lo Flame Adjustment FV7FBT Decorative Brass Collar 7 F7DBC Decorative Black Collar 7 F7DTP Decorative Black Wall Trim Plate OFP42SA Spark Assist VENTING KITS AND COMPONENTS VENTING ACCES...

Страница 33: ...si Nut Electrode Universal Bushing 974 144 1000 214 Piezo Igniter 1244 17 Mark21 1000 P136WR Generator GOA1 524 1000 255 Orifice Burner VALVE SYSTEM PARTS IPI System Electronic Ignition Remote Control...

Страница 34: ...tch If okay jumper wires across wall switch wires at valve If burner comes on wires are faulty or connections are bad Generator may not be Check generator with millivolt meter Take reading at generato...

Страница 35: ...th service or maintenance h damage repairs inoperation or inefficiency resulting from faulty installation or application i electricity or fuel costs or any increase in electricity or fuel cost whatsoe...

Отзывы: