Burner System Maintenance
It is recommended to annually inspect and clean the Burner System to prevent malfunction and / or sooting. This
operation should be performed by your dealer or a qualified technician.
-CAUTION-
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all
electrical connections to the appliance. Allow the appliance to cool to room temperature. Note
that the pilot assembly may be hot in an intermittent or standing-pilot system—even if the main
burner was never on. Exercise caution when working within the area.
-ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN-
Monthly Flame Inspection
It is recommended to turn on the unit at least once a month and inspect the flame pattern to ensure there are no problems
with the burner tube. The pilot flame should also be inspected monthly to ensure proper operation.
Flame should appear similar to the above picture.
Conversion Kit Instructions – PART A
Kit Number
Description Pilot
Orifice
Burner Orifice
Brass (1000-255)
Brass Nipple
Air
Shutter
Hi/Lo Regulator
200DV-CKLP
(FDV200LP,
FDV200PLP)
LP Conversion
-Millivolt-
1001-P167SI
#30 (977.167)
#51
1000-253 closed
Full
Open
1001-P202SI
(0.907.202)
200DV-CKNG
(FDV200N,
FDV200PN)
NG Conversion
-Millivolt-
1001-P165SI
#51 (977.165)
#35
1000-253 closed
3/8”
1001-P201SI
(0.907.201)
200DV-CKLPI
(FDV200LPE,
FDV200PLPE)
LP Conversion
-IPI -
1001-P168SI
#35 (977.168)
#51
1000-253 closed
Full
Open
1002-P014SI
(0.907.014)
200DV-CKNGI
(FDV200NE,
FDV200PNE)
NG Conversion
- IPI -
1001-P166SI
#62 (977.166)
#35
1000253 closed
3/8”
1002-P016SI
(0.907.016)
Refer to “
Gas Specifications Chart
” for inlet pressures and input ratings. Clock meter to verify input rate. Place conversion label as close
to converted gas control as possible. Refer to lighting instructions to verify the normal operating sequence of the ignition system.
IMPORTANT: Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK TESTING.
15
Содержание FDV200
Страница 18: ...Gas Conversion for Modulator PART C WARNING WARNING 18...
Страница 21: ...Configuration 1 Basic manual HI LO and manual ON OFF capabilities 21...
Страница 22: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 22...
Страница 23: ...Receiver Module 584 523 521 221 1001 P221SI Receiver Module 584 523 521 221 1001 P221SI 23...