 WARNING

 

FOR SAFE INSTALLATION AND OPERATION OF YOUR GAS FIREPLACE PLEASE NOTE THE FOLLOWING: 

1. 

when an appliance is for connection to a fixed piping system, the installation must conform with local codes or, 

in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 • NFPA 54; National Fuel Gas 

Code; Natural Gas and Propane Installation Code, CSA B149.1; or Propane Storage and Handling Code, CSA 

B149.2, as applicable. 

2. 

THIS UNIT IS NOT FOR USE WITH SOLID FUEL. 

3. 

Always keep the appliance clear and free from combustible materials, gasoline, and other flammable vapors 

and liquids. 

4. 

Inspect the fuel supply connection (including the hose for LP models) before each use of the appliance. See 

Lighting Instructions for removal of Access Panel. 

5. 

If it is evident there is excessive abrasion or wear, or the hose is damaged, it must be replaced prior to the 

appliance being put into operation. Locate the hose out of pathways where people may trip over it or in areas 

where the hose may be subject to accidental damage 

6. 

Locate the hose out of pathways where people may trip over it or in areas where the hose may be subject to 

accidental damage. 

7. 

Children and adults should be alerted to the hazards of the high surface temperatures of this appliance and 

should stay away to avoid burns or ignition of clothing. 

8. 

Young children should be carefully supervised when they are in the area of the appliance. 

9. 

Clothing or other flammable material should not be placed on or near the appliance. This appliance should not 

be used as a drying rack for clothing. 

10. 

Any safety screen or guard removed for servicing an appliance must be replaced prior to operating the 

appliance. 

11. 

Installation and repair should be done by a qualified service person. The appliance should be inspected before 

use and at least annually by a professional service person. More frequent cleaning may be required due to 

excessive lint from carpeting, et cetera. It is imperative that control compartments, burners and circulating air 

passageways of the appliance be kept clean.  

12. 

Do not use this appliance if any part has been under water. Immediately call a qualified service technician to 

inspect the unit and to replace any part of the control system and any gas control which has been underwater. 

LP Cylinder Requirements

 

The LP gas supply cylinder used with LP models must be constructed and marked in accordance with the 

specifications for LP-gas cylinders of the U.S. Department of Transportation (DOT) 

Specifications for LP-Gas 

Cylinders, or the Standard for Cylinders, Spheres and Tubes for Transportation of Dangerous Goods and Commission

CAN/CSA-B339, as applicable. 

  The LP gas supply cylinder used with LP models must be provided with a listed overfilling prevention device. 

  The pressure regulator and hose assembly supplied with LP models (PN# 

27FP-900FF

) must be used. 

  Replacement pressure regulators and hose assemblies must be those specified in this manual. 

  Always check for gas leaks with a soap and water solution. DO NOT USE OPEN FLAME FOR LEAK 

TESTING. 

  When an LP model is not in use, the LP-gas must be turned off at the supply cylinder. 

  At altitudes above 4500ft appliances should be derated 4% every 1000ft. However, check with local gas 

supplier as fuel supply may already be adjusted. 

  Refer to 

Assembly and Installation 

for leak testing procedures. 

  Refer to 

Gas Specifications 

for gas inlet pressures. 

  Refer to 

Gas Specifications 

for input rates.  

  Refer to 

Lighting Instructions

 for normal sequence of the ignition system. 

 

4

Содержание FP2085

Страница 1: ...se Only Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may...

Страница 2: ...y and its operation including remote control operation if included is fully explained to and understood by the customer Important Information About Outdoor Fireplaces Before you build in this applianc...

Страница 3: ...C85 Placement Instructions 14 Accessories for Your Fire Pit Bola Fire Bowls 15 24OBT MANCP Control Panel for FP2085T Fire Pits in Custom Enclosures 16 FP20SSRT Stainless Steel Ring Dimensions Accessor...

Страница 4: ...eplaced prior to operating the appliance 11 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional se...

Страница 5: ...Within a partial enclosure that includes an overhead cover and no more than two side walls 3 These side walls may be parallel as in a breezeway or at right angles to each other 4 Within a partial encl...

Страница 6: ...minimum enclosure dimensions of 32 1 2 x 39 1 2 I D The top of enclosure must be of a non combustible material such as concrete board or wonder board 2 Clearance to combustible side wall is 24 minimu...

Страница 7: ...ish on top of Wonder Board Do not use any combustible materials to finish top e g wood or plastic products 4 You must have an opening in the enclosure to have access to the on off valve 5 A minimum of...

Страница 8: ...D Inside corners of shields should not touch combustible wall Shield must extend 3 past end of firepit Fig 1 Ref E 4 Note Firepit cabinet or other structures must NOT obstruct wall shield air space on...

Страница 9: ...and make sure it is tight NOTE Fuel Supply line must not come into contact with surfaces having temperatures in excess of 140 F LP gas cylinder must be kept a minimum of 4 5 feet from the appliance Yo...

Страница 10: ...can be opened without the use of tools Designs using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or equivalent at a minimum of 180 degrees apart to facilit...

Страница 11: ...fice into Air Shutter 5 Re attach Orifice Retainer Bracket to Burner Tray 6 Connect LP Hose and Regulator to Valve Assembly WARNING This conversion kit shall be installed by a qualified service agency...

Страница 12: ...sition the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 15 BRASS CAP ORIFICE PRIMARY...

Страница 13: ...accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 15 BRASS CAP ORIFICE PRIMARY AIR 1 4 NATURAL GAS...

Страница 14: ...p the gas connection make sure that logs are not broken Identify the logs using the pictures below and place logs as indicated lining up with mounting pegs in logs STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 T...

Страница 15: ...1 2 holes for drainage Fire Pit Bowl for FP2085T Round Fire Pit Valve Igniter Mount Box KINGSMAN OUTDOOR FIRE BOWLS FOR THE 2085T FIRE PIT Fire Bowl Includes Valve Igniter Mount Box 1 4 Lava Rock 10...

Страница 16: ...e Valve Control Panel is 2 7 16 tall x 7 1 2 wide The Control Panel is inserted from the inside of the enclosure and set in place by tightening the 2 screws on the back of the Control Panel Assembly B...

Страница 17: ...as Valve Control Knob and Igniter Button from the Fire Pit 2 Align the 2 round holes in the Stainless Steel Trim Ring with the Gas Valve and the Igniter on the Fire Pit and lower it into place 3 Repla...

Страница 18: ...s FPB30TBT FPB30SGT Place Trim Ring over concrete bowl Screws are not required FPB32SGT Place Trim Ring over concrete bowl Tighten screws until they touch the concrete bowl DO NOT OVER TIGHTEN SCREWS...

Страница 19: ...ly mist the surface every 6 months to check the water repellency Friction will wear away product more quickly leaving the fabric unprotected If this is the case such areas can be spot treated to renew...

Страница 20: ...AGS 30 35LBS 6 7 BAGS MQG5B 1 2 Black Glass 5LBS 20LBS 4 BAGS 20LBS 4 BAGS 30 35LBS 6 7 BAGS MQG10C 1 4 Reflective Bronze Glass 10 LBS 20LBS 2 BAGS 20LBS 2 BAGS 30 35LBS 3 4 BAGS MQG10B 1 4 Black Glas...

Страница 21: ...va Rock Supplied with Fire Pit 1 4 Lava Rock is used as Base Reflective Bronze Glass 20LBS MQSTONE with Lava Rock Base 10LBS MQSTONE with Bronze Glass Base 20LBS NOTE MQSTONE Requires a Glass or Lava...

Страница 22: ...o examine the area around the burner air shutter Any dirt or lint in this area should be removed This will ensure long life and trouble free operation Re install the logs as shown in the log placement...

Страница 23: ...reach your gas supplier call the re department Manual Valve with Push Button Ignition 1 STOP Read the safety information above 2 Remove the top cover 3 Find the manual gas control valve and push butto...

Страница 24: ...s Steel Flex Connector 16 Qty 2 for FP2085NT Qty 1 for FP2085LPT 3 8 Stainless Steel Flex Connector 10 Qty 1 for FP2785LPT FL 8 24OB PHP1003 Thermocouple 9 4000 P963VE 3 8 Tube OD x 3 8 Male Pipe 10 2...

Страница 25: ...07 Flat Lid for FP2785T FP20SSRT Stainless Steel Ring Fits FP2085NT FP2085LPT 24OBT MANCP Control Panel for FP2085NT FP2085LPT Round Fire Pits in custom enclosures OUTDOOR FIRE BOWLS FOR THE 2085T FIR...

Страница 26: ...areas to help clear the area of residual gas before attempting to relight the appliance Natural gas is lighter than atmospheric air and will tend to rise and collect in higher areas while propane is...

Страница 27: ...y conditions are not recommended for operation of the appliance as flames are being blown out of the combustion area and can be very hazardous causing personal or property damage Also if the flame is...

Страница 28: ...nd or handling charges associated with any repair or replacement pursuant to this limited warranty will be your responsibility In this warranty the word installation means original installation We wil...

Отзывы: