INTER-CONNECTING

YOUR SMOKE ALARMS

2

. Install a minimum of two smoke

alarms in every home, no matter how

small the home.

3

. Install a smoke alarm in each room

that is divided by a partial wall either

coming down from the ceiling at least

8 inches, or coming up from the floor.

4

. Install a smoke alarm in lived-in attics

or attics which house electrical

equipment like fires, air conditioners or

heaters.

DO NOT INSTALL SMOKE ALARMS -

1

.

Near appliances or areas where

normal combustion regularly occurs

such as kitchens, near fires or hot

water heaters.

2

.

In areas with high humidity

, like

bathrooms or areas near dishwashers

or washing machines. Install at least

10

feet away from these areas.

3

.

Near air returns or heating and

cooling supply vents

. Install at least

3

feet away from these areas. The air

could blow smoke away from the

detector, interrupting its alarm.

4

. Do not install smoke alarms in

rooms

where temperatures

may fall below

4

°

C or rise above

38

°

C.

5

.

In extremely dusty, dirty areas

or

insect-infested areas where loose

particles could interfere with the

smoke alarms operation.

WARNING:

This alarm is mains powered

and requires wiring in accordance with

the current IEE Regulations for Electrical

Installations (BS

7671

).

The circuit used to power the smoke

alarm must be a dedicated permanent

supply that cannot be switched off

accidentally by the normal user. Before

installing ensure the electrical supply is

isolated.

1

. Isolate the power supply by switching

off at the mains.

PLEASE NOTE:

The alarm will not

mount to the plate if the battery is not

installed. You must install the battery.

14

.You can now turn the mains power

supply back on and test your alarm.

See the ‘Testing’ section.

For inter-connecting line, use only

1.0

mm

2

to

1.5

mm

2

solid or stranded

wire. When inter-connecting, the maxi-

mum wire length can be up to

1500

feet

between any two alarms using

1.0

mm

2

or

4000

feet for

1.5

mm

2

.

(

20

Ohms loop

resistance).

This alarm can be inter-connected with

as many as

40

KingShield smoke or heat

alarms. Do not try to connect to any

other type or model of alarm other than

KingShield models.

Once the alarm has been installed a

small green LED indicator light should

be visible through the alarm grill, indicating

that it is receiving AC supply. A red LED

indicator light should also flash once a

minute to indicate the battery is healthy

and the unit is operating properly.

If smoke is detected, the unit will emit a

loud pulsating alarm and a red indicator

light will flash quickly and will continue

to do so until the air is clear.

The ‘HUSH’ feature can mute the detector

if it has been advertently triggered by

holding down the ‘TEST/HUSH’ button

for a few seconds. The alarm will be

muted for

10

minutes and then will reset

into normal mode.

2

. Remove the mounting plate from the

back of the alarm by turning the plate

counter clockwise.

3

. Gently pull the wires through the

centre hole of the plate.

4

. Secure the plate to the ceiling or wall

with mounting screws.

5

. With a three way connector block,

connect the brown wire from the

connector plug to the brown/red

household wire.

6

. Connect the blue wire from the

connector plug to the blue/black

household wire.

7

. If you want to inter-connect more

alarms, connect the yellow wire from

the connector to the inter-connection

wire between the smoke alarms. See

‘Inter-Connecting Your Smoke Alarms’

section.

If it is a single alarm you are installing,

simply cover the yellow wire with

electrical tape and tuck it into the

junction box.

8

. Lift open the battery pocket door.

9.

Connect the new

9

V battery to the

battery connector inside the battery

pocket. Be sure that the battery is

securely connected. The alarm may

beep briefly when the battery is

installed.

10.

Close the battery pocket door,

snapping it into place.

11

.Attach the connector plug to the pins

on the back of the alarm. The plug will

only fit one way and will snap into

place.

12.

Gently tug the connector to be sure it

is attached securely.

13.

Position the alarm on the mounting

plate and turn clockwise to lock into

place. To engage the tamper resist

feature, insert the pin into the notch

on the edge of the alarm when the

alarm is properly positioned on the

mounting plate.